Input Signals
Digital Inputs
Enable
[digital]
When this signal is high the module will communicate with the Anthem. When the signal
goes low the module will not send out any data. For an IP connection this should be tied to the TCP/IP
Clients Connect-F signal.
PowerON
[digital]
The Power ON join is used to power the main zone on. The command gets sent on the rising edge of this
join, the trailing edge has no effect. During the power on sequence the amplifier will update feedback for a
number of items, a process that takes about 1 second, so its best to leave it some time to do that before
attempting further control.
PowerOFF
[digital]
The Power OFF join is used to power the main zone down. The command gets sent on the rising edge of this
join, the trailing edge has no effect.
VolumeUp
[digital]
The Volume Up Command is used to raise the volume of the main zone. The command is a single shot, so if
you want to perform a press and hold you will need to run this signal through an oscillator (OSC). This
command affects the volume percentage so you will want to configure the amplifier to display percentage.
VolumeDown
[digital]
The Volume Down Command is used to lower the volume of the main zone. The command is a single shot, so
if you want to perform a press and hold you will need to run this signal through an oscillator (OSC). This
command affects the volume percentage so you will want to configure the amplifier to display percentage.
VolumeDBUP
[digital]
The Volume DB Up Command is used to raise the volume of the main zone. The command is a single shot, so
if you want to perform a press and hold you will need to run this signal through an oscillator (OSC). This
command affects the volume by incrementing the DB so you will want to configure the amplifier to display
DB.
VolumeDBDown
[digital]
The Volume DB Down Command is used to lower the volume of the main zone. The command is a single
shot, so if you want to perform a press and hold you will need to run this signal through an oscillator (OSC).