Anthem Integrated 2 Скачать руководство пользователя страница 1

We at Sonic Frontiers hope you will derive many years

of listening pleasure with your new Anthem Integrated 2.

This Operating Manual contains important information

regarding the operation and care of the Integrated 2. 

Be sure to read this manual carefully and follow these

instructions in order to keep your unit performing and

sounding its best. Please contact Sonic Frontiers if you

have any questions, a Customer Service Representative

will be pleased to assist you.

WHAT’S IN THE BOX?

In addition to the Integrated 2, it’s cover, and the o

ating manual you are presently reading (with associa

inserts and warranty card), there are a few more item

take inventory of before steps are taken to make the

Anthem Integrated 2 operational. 

These items are:

• 2 6DJ8/6922 tubes

• a glove for handling the tubes

• a detachable AC power cord

• 18 phillips screws

• a phillips screwdriver

• remote handset

After completing an inventory of these items, proce

to the next steps.

H N I C A L   S P E C I F I C A T I O N S

TS (6):

CD, Tuner, Aux 1, Aux 2/Phono, Tape, SSP

PUTS (4):

Tape, Preamplifier, Main Power Amplifier,

tereo Headphone Jack

TROLS (3):

Input Select, Balance, Volume

CHES (5):

SSP, Tape/EPL (External Processor

, Mono/Stereo, Mute/Operate, Power On/Off 

 COMPLEMENT:

2-6DJ8/6922

ER REQUIREMENTS:

100-120VAC 60Hz (Export

40VAC 50/60Hz) - 400VA

NSIONS:

19" (48 cm) W x 5.25" (13.5 cm) H x 16”

m) D, Knobs extend 3/4" (1.9 cm) forward of panel 

WEIGHT:

38 Ibs, (17.2 kg) - unpacked

G R ATE D  AM PL IF I ER   SP ECI F ICAT I O N S

D POWER:

90 Watts (25.5Vrms) into 8 ohms - 

uous; or 145 Watts (23Vrms) into 4 ohms; both

els driven 20Hz to 20kHz @ <1% THD&N

UENCY RESPONSE:

-0.5dB 20Hz to 35kHz 

); -3.0dB 10Hz to 95kHz (@ 1W)

AL TO NOISE RATIO:

 -95dB (A-weighted ref 80W

power); 

 -90dB (Unweighted ref 80W rated power)

&N:

 0.1% 1kHz @ rated power,

% 30Hz to 15kHz @ rated power,

8Hz to 23kHz @ rated power

SE:

Non Inverting

T IMPEDANCE:

40k ohms (Line level inputs)

39dB

ITIVITY:

280mV input for rated power, 8 ohms

me control @ maximum)

PR E AM P L IF IE R  SP EC IF I C AT IO N S  

(Line Level Inputs to Pre Outputs)

INPUT IMPEDANCE:

 40k ohms (line level inputs)

OUTPUT IMPEDANCE:

150 ohms (minimum required

load: 10k ohms)

FREQUENCY RESPONSE:

-0.5dB 20Hz to 90kHz, 

-3.0dB 1Hz to 200kHz

SIGNAL TO NOISE RATIO:

 -90dB (Unweighted ref 1V

@ Pre Out); 

 -95dB (A-weighted ref 1V @ Pre Out)

THD&N:

0.01% 10Hz to 50kHz 

(Ref 1V @ Pre Out)

PHASE:

Non Inverting

GAIN:

15dB (5.7x)

PO WE R  A M PL IFI ER   SPE C I F ICAT I O N S

(SSP Input(s) to Main Speaker Output)

RATED POWER:

90 Watts into 8 ohms - continuous; or

145 Watts into 4 ohms; both channels driven; both chan-

nels driven; 20Hz to 20kHz @ <0.1% THD&N 

FREQUENCY RESPONSE:

-0.5dB 10Hz to 40kHz (1W); 

-3.0dB 15Hz to 100kHz (1W) 

SIGNAL TO NOISE RATIO:

 -100dB (A-weighted ref

80W rated power); 

 -90dB (Unweighted ref 80W rated

power)

THD&N:

0.1% 20Hz to 20kHz @ rated power; 

PHASE:

Polarity Non-inverting

INPUT IMPEDANCE:

19k ohms (Power Amplifier Inputs)

DAMPING FACTOR:

100 @ 8 ohms

GAIN:

24dB (16x)

SENSITIVITY:

1.6VRMS input for rated power

This symbol is intended to alert the user to the

presence of uninsulated “dangerous voltage”

within the product’s enclosure that may be of

sufficient magnitude to constitute a risk of 

electric shock to persons.

This symbol is intended to alert the user to 

the presence of important operating and 

maintenance (servicing) instructions in the 

literature accompanying the appliance.

Содержание Integrated 2

Страница 1: ...nto 4 ohms both els driven 20Hz to 20kHz 1 THD N UENCY RESPONSE 0 5dB 20Hz to 35kHz 3 0dB 10Hz to 95kHz 1W AL TO NOISE RATIO 95dB A weighted ref 80W power 90dB Unweighted ref 80W rated power N 0 1 1kH...

Страница 2: ...be returned to the sender freight collect Units to be repaired by Sonic Frontiers Inc must be sent shipping and insurance prepaid by the original purchaser in the original packing material A returned...

Страница 3: ...accident neglect or in being transported or the defect is due to the product being tampered with modi fied or repaired by anyone other than Sonic Frontiers Inc or an authorized Sonic Frontiers repair...

Страница 4: ...proper electrical contact 3 DISCONNECT THE AC POWER CORD wait 5 minutes check that A slo blo fuse with a rating of 4 Amp 250 V 2 Amp 2 for European and Asian versions is installed in the fuse er direc...

Страница 5: ...as power amplifiers or a crossover unit connect left channel to left channel and right channel to right channel The Pre Out jacks allow the Integrated 2 to be used solely as a preamp These outputs are...

Страница 6: ...tubes are labeled V1 V2 Place each tube in the corre sponding position according to figure 1 above S T U V O T E C O N T R O L F U N C T I O N S S VOLUME CONTROL UP This button will increase the volum...

Страница 7: ...E S I G N E D A N D M A N U F A C T U R E D B Y S O N I C F R O N T I E R S I N T E R N A T I O N A L A N T H E M I N T E G R A T E D 2 O P E R A T I N G M A N U A L...

Отзывы: