Installation and Connection

1. 

Before placing the device into its operating location, consider the following:

 

The device’s ventilation outlets should not be obstructed by other devices and objects and 

enough space for air circulation should be provided.

 

The device should not be placed next to any heat-sensitive piece of equipment. (The 

surface of ISOCHRONE 10M may reach a temperature of 55°C (140°F) during operation.)

 

To minimize frequency instabilities, the device should not be placed near equipment 

generating strong magnetic fields, such as generators, transformers, etc.

 

To prevent possible interference, observe a minimum distance of 5 centimeters (2 inches) 

between the cables of this device and any non-coaxial audio cables.

 

It is OK to use the device unmounted (i.e. not in a rack) as long as the above conditions are 

met. There is no requirement for the device to be leveled horizontally.

2.  If the DC Power Connection (7) is to be used, make sure the power cord is wired properly, 

because reversed polarity may damage the device. Refer to the illustration and the table 

below for information on how to make the connection. If in doubt consult a competent 

echnician.

If the mark on the Speakon NL4FX plug is…

connect to the following mark on the power 

supply unit circuit board / terminal:

1+

+15 V

2-

Ground

1-

Earth

(

optional, use it if available On the power supply unit

)

3.  Mount the device on its operating place in the rack and secure it with the screws.

4.  Connect the AC Power Connection (6) and/or the DC Power Connection (7) to the respective 

power outlet(s).

5.  Connect the devices you would like clocked to the Atomic Clock Outputs 1-8 (8) on the rear 

panel. (These devices must support 10 MHz atomic clock signal input.)

Note:

 When connecting the devices, do so with the studio volume turned down. Some devices may 

emit unpleasant sound until properly configured to accept incoming clock.

Operation

1.  Power the device on by depressing the Power Switch (1) on the front panel. Depending 

on the connected power sources, the Power Supply Indicator(s) (2) and/or (3) will go up.

2.  If the connected slave devices are off, power them on.

3.  Make sure the atomic clock indicators of the slave devices show that the 10 Mz clocking 

signal is received properly. Some devices will automatically synch to the incoming clock 

from the ISOCHRONE 10M when connected; others may require additional configuration in 

order to utilize 10 MHz clock.

1

6

Содержание Isochrone 10M

Страница 1: ......

Страница 2: ......

Страница 3: ...Contents Safety notes 2 Introduction 3 Product Overview 3 Front Panel 4 Rear Panel 5 Wiring Diagram 5 Installation and Connection 6 Operation 6 Technical Specifications 7 1 1 ...

Страница 4: ...wall outlet always pull the plug not the power cord Make sure ventilation outlets are not obstructed putting things on the cabinet or using the device in a narrow and poorly ventilated place may result in the temperature rising which could affect its operation or the operation of other closely located components If anything goes wrong turn off the device first and then unplug the power cords Do no...

Страница 5: ...1 000 years As a result staging transparency imaging separation and depth are vastly improved and render the warmth and fullness typically associated with analog sound The heart of the ISOCHRONE 10M is a Swiss made high precision sub miniature Rubidium oscillator which is 100 000 times more stable than the typical crystal oscillator Rubidium is a very soft and highly reactive element forming alloy...

Страница 6: ...n displays the following message Please wait the rubidium generator is warming up The device is operable in this state but the clock frequency has not yet reached its specified ultimate stability Once the device is fully warmed up the message is replaced by 10M which means maximum stability has now been achieved the clock frequency stability meets specifications and the device is ready for use 5 W...

Страница 7: ...ing its peak consumption period the warm up when 40 Watts of power are required The 15V power supply units designed for telecommunication devices typically meet this power output requirement 8 Atomic Clock Outputs 1 8 BNC outlets for the 10 MHz atomic clock signal For best results the cables should not exceed 6 meters 20 feet in length Longer cable runs result in increased jitter and other clock e...

Страница 8: ...ke the connection If in doubt consult a competent echnician If the mark on the Speakon NL4FX plug is connect to the following mark on the power supply unit circuit board terminal 1 15 V 2 Ground 1 Earth optional use it if available On the power supply unit 3 Mount the device on its operating place in the rack and secure it with the screws 4 Connect theAC Power Connection 6 and or the DC Power Conn...

Страница 9: ...PB per 100 seconds Phase noise 10 MHz Standard 140 dBc per Hz at 10 kHz Warm Up Time 8 10 minutes depends on ambient temperature Power Supply Type AC and DC Dual Redundant Power Supply Input 100 240V AC 50 60 Hz 15 V DC Power Consumption 40 W during the warm up 17 W at standard operation after the warm up Inrush Current Maximum 50A at 264 V AC Atomic Clock Output 8 x BNC Sinusoidal 10 MHz 75 Ohm 1...

Страница 10: ...NOTES 1 8 ...

Страница 11: ......

Страница 12: ......

Отзывы: