background image

Safety notes

To reduce the risk of electrical shocks, fire, and related hazards:

 

Do not remove screws, cover, or cabinet. There are no user serviceable parts inside. Refer 

servicing to qualified service personnel.

 

Do not expose this device to rain, moisture or spillover of liquid of any kind.

 

Do not insert foreign objects into the ventilation outlets of the cabinet.

 

Should any form of liquid or a foreign object enter the device, do not use it. Switch off the 

device and then unplug it from the power source. Do not operate the device again until the 

foreign object is removed or the liquid has completely dried and its residues fully cleaned 

up. If in doubt, please consult the authorized repair service.

 

Do not handle the power cords with wet hands!

 

Make sure the device is switched off when plugging/unplugging it to/from the power source.

 

When unplugging from the wall outlet always pull the plug, not the power cord.

 

Make sure ventilation outlets are not obstructed: putting things on the cabinet or using the 

device in a narrow and poorly ventilated place may result in the temperature rising which 

could affect its operation or the operation of other closely located components.

 

● If anything goes wrong, turn off the device first and then unplug the power cords. Do not 

attempt to repair the device yourself: consult the authorized service personnel or your 

dealer.

Important

About the 15V DC power supply option, please note the following:

 

Improper application of the 15V DC power supply may damage the device. When connecting 

the 15V DC power cord to the power source, make sure to comply with the circuit diagram 

given in this manual so that the correct polarity is applied. If in doubt - consult a competent 

electronics technician.

 

Make sure the power supply source is capable of producing enough power to meet the 

requirements of the device during its peak consumption period (the warm-up) when 40Watts 

of power are required.

1

2

Содержание Isochrone 10M

Страница 1: ......

Страница 2: ......

Страница 3: ...Contents Safety notes 2 Introduction 3 Product Overview 3 Front Panel 4 Rear Panel 5 Wiring Diagram 5 Installation and Connection 6 Operation 6 Technical Specifications 7 1 1 ...

Страница 4: ...wall outlet always pull the plug not the power cord Make sure ventilation outlets are not obstructed putting things on the cabinet or using the device in a narrow and poorly ventilated place may result in the temperature rising which could affect its operation or the operation of other closely located components If anything goes wrong turn off the device first and then unplug the power cords Do no...

Страница 5: ...1 000 years As a result staging transparency imaging separation and depth are vastly improved and render the warmth and fullness typically associated with analog sound The heart of the ISOCHRONE 10M is a Swiss made high precision sub miniature Rubidium oscillator which is 100 000 times more stable than the typical crystal oscillator Rubidium is a very soft and highly reactive element forming alloy...

Страница 6: ...n displays the following message Please wait the rubidium generator is warming up The device is operable in this state but the clock frequency has not yet reached its specified ultimate stability Once the device is fully warmed up the message is replaced by 10M which means maximum stability has now been achieved the clock frequency stability meets specifications and the device is ready for use 5 W...

Страница 7: ...ing its peak consumption period the warm up when 40 Watts of power are required The 15V power supply units designed for telecommunication devices typically meet this power output requirement 8 Atomic Clock Outputs 1 8 BNC outlets for the 10 MHz atomic clock signal For best results the cables should not exceed 6 meters 20 feet in length Longer cable runs result in increased jitter and other clock e...

Страница 8: ...ke the connection If in doubt consult a competent echnician If the mark on the Speakon NL4FX plug is connect to the following mark on the power supply unit circuit board terminal 1 15 V 2 Ground 1 Earth optional use it if available On the power supply unit 3 Mount the device on its operating place in the rack and secure it with the screws 4 Connect theAC Power Connection 6 and or the DC Power Conn...

Страница 9: ...PB per 100 seconds Phase noise 10 MHz Standard 140 dBc per Hz at 10 kHz Warm Up Time 8 10 minutes depends on ambient temperature Power Supply Type AC and DC Dual Redundant Power Supply Input 100 240V AC 50 60 Hz 15 V DC Power Consumption 40 W during the warm up 17 W at standard operation after the warm up Inrush Current Maximum 50A at 264 V AC Atomic Clock Output 8 x BNC Sinusoidal 10 MHz 75 Ohm 1...

Страница 10: ...NOTES 1 8 ...

Страница 11: ......

Страница 12: ......

Отзывы: