Страница 3: ...Contents Safety notes 2 Introduction 3 Product Overview 3 Front Panel 4 Rear Panel 5 Wiring Diagram 5 Installation and Connection 6 Operation 6 Technical Specifications 7 1 1 ...

Страница 4: ...wall outlet always pull the plug not the power cord Make sure ventilation outlets are not obstructed putting things on the cabinet or using the device in a narrow and poorly ventilated place may result in the temperature rising which could affect its operation or the operation of other closely located components If anything goes wrong turn off the device first and then unplug the power cords Do no...

Страница 5: ...1 000 years As a result staging transparency imaging separation and depth are vastly improved and render the warmth and fullness typically associated with analog sound The heart of the ISOCHRONE 10M is a Swiss made high precision sub miniature Rubidium oscillator which is 100 000 times more stable than the typical crystal oscillator Rubidium is a very soft and highly reactive element forming alloy...

Страница 6: ...n displays the following message Please wait the rubidium generator is warming up The device is operable in this state but the clock frequency has not yet reached its specified ultimate stability Once the device is fully warmed up the message is replaced by 10M which means maximum stability has now been achieved the clock frequency stability meets specifications and the device is ready for use 5 W...

Страница 7: ...ing its peak consumption period the warm up when 40 Watts of power are required The 15V power supply units designed for telecommunication devices typically meet this power output requirement 8 Atomic Clock Outputs 1 8 BNC outlets for the 10 MHz atomic clock signal For best results the cables should not exceed 6 meters 20 feet in length Longer cable runs result in increased jitter and other clock e...

Страница 8: ...ke the connection If in doubt consult a competent echnician If the mark on the Speakon NL4FX plug is connect to the following mark on the power supply unit circuit board terminal 1 15 V 2 Ground 1 Earth optional use it if available On the power supply unit 3 Mount the device on its operating place in the rack and secure it with the screws 4 Connect theAC Power Connection 6 and or the DC Power Conn...

Страница 9: ...PB per 100 seconds Phase noise 10 MHz Standard 140 dBc per Hz at 10 kHz Warm Up Time 8 10 minutes depends on ambient temperature Power Supply Type AC and DC Dual Redundant Power Supply Input 100 240V AC 50 60 Hz 15 V DC Power Consumption 40 W during the warm up 17 W at standard operation after the warm up Inrush Current Maximum 50A at 264 V AC Atomic Clock Output 8 x BNC Sinusoidal 10 MHz 75 Ohm 1...