background image

 

 

 

LNX-C800 Series 

8-Port Compact Industrial Unmanaged Ethernet Switch, with 8*10/100Tx 

 

Hardware Manual 

 

Version 2.0 

(September 2020) 

 

 

Содержание LNX-C800 Series

Страница 1: ...LNX C800 Series 8 Port Compact Industrial Unmanaged Ethernet Switch with 8 10 100Tx Hardware Manual Version 2 0 September 2020 ...

Страница 2: ... fitness for a particular purpose Antaira Technologies LLC may make improvements and or changes to the product and or specifications of the product described in this manual without prior notice Antaira Technologies LLC will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are periodically made to the information contained herein and will be incorpora...

Страница 3: ...ons radio si l équipement n est pas installé et utilisé conformément aux instructions Cependant il n y a aucune garantie qu aucune interférence ne se produira dans une installation particulière Si cet équipement provoque des interférences nuisibles à la réception radio ou télévision ce qui peut être déterminé en éteignant puis en rallumant l équipement l utilisateur est encouragé à essayer de corr...

Страница 4: ...Industrial Grade Unmanaged Ethernet Switches Hardware Manual Version 2 0 September 2020 The manual supports the following models LNX C800 LNX C800 T This document is the current official release hardware manual Please check our website www antaira com for any updated manual or contact us by e mail support antaira com ...

Страница 5: ... 2 1 Physical Dimensions 3 2 2 Front View Panel 4 2 3 Top View Panel 4 2 4 LED Indicators 5 2 5 Ethernet Ports 5 2 6 Cabling 6 2 7 Wiring the Power Inputs 6 2 8 Wiring the Fault Alarm Contact 7 2 9 Grounding Note 8 3 Mounting Installation 9 3 1 DIN Rail Mounting 9 3 2 Wall Mounting 10 4 Hardware Installation 12 4 1 Installation Steps 12 4 2 Maintenance and Service 13 4 3 Troubleshooting 13 5 Techn...

Страница 6: ...models for either a standard temperature range STD 10 C to 65 C or an extended temperature range EOT 40 C to 75 C 1 1 Product Hardware Features System Interface and Performance All RJ45 ports support Auto MDI MDI X Function Embedded 8 10 100Tx RJ45 ports Store and forward switching architecture 1K MAC address table Product Input DC 12 48V redundant with a 6 pin removal terminal block The power inp...

Страница 7: ...mentation Les spécifications matérielles les ports les informations de câblage et l installation du câblage du commutateur Ethernet industriel seront décrits dans ce manuel d utilisation Warning Labels The caution label means that you should check the certain information on the user manual when working with the device Shown in Figure 1 1 Étiquettes d avertissement L étiquette d avertissement signi...

Страница 8: ...thernet Switches LNX C800 Series Hardware Manual v2 0 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 40mm x 70mm x 95mm Figure 2 1 Physical Dimensions 3 ...

Страница 9: ...LNX C800 Series Hardware Manual v2 0 2 2 Front View Panel Figure 2 2 below shows the front panel of the product series Figure 2 2 Front View Panel 2 3 Top View Panel Figure 2 3 below shows the top panel of the product series Figure 2 3 Top View Panel 4 ...

Страница 10: ...1 and 2 are both functional LAN Port 1 8 Upper LED Green On Connected to network 100Mbps Flashing Networking is active Off Not connected to network LAN Port 1 8 Lower LED Green On Connected to network 10Mbps Flashing Networking is active Off Not connected to network Table 2 1 LED Indicators Note P1 is the abbreviation for Power 1 P2 is for Power 2 LNK is for Link and ACT is for Activity 2 5 Ethern...

Страница 11: ...gory 5e or the above cabling for the RJ45 port connections The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft in length 2 7 Wiring the Power Inputs Caution Please follow the steps below when inserting the power wire Attention Veuillez suivre les étapes ci dessous lors de l insertion du câble d alimentation 1 Insert the positive and nega...

Страница 12: ... en cuivre 125 C serrez à 5 lb Le calibre des fils du bornier doit être compris entre 18 et 20 AWG 2 8 Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connector as the picture shows below in Figure 2 6 By inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch only and form a normal ope...

Страница 13: ...alimentation connectez les broches 1 à 5 et les broches 2 à 6 pour éliminer l alarme de panne de courant 2 9 Grounding Note Grounding and wire routing help limit the effects of noise due to Electromagnetic Interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices The grounding screw symbol is shown below in Figure 2 7 Figure 2 7 Grounding...

Страница 14: ...ear side of the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l appareil est de 3 5 pouces livres 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figure...

Страница 15: ...industriel 1 Remove the DIN Rail bracket from the industrial Ethernet switch by loosening the screws 2 Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l appa...

Страница 16: ...strial Ethernet Switches LNX C800 Series Hardware Manual v2 0 Figure 3 4 Remove DIN Rail bracket from the Switch Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall Mounting Bracket Dimensions 11 ...

Страница 17: ...switch If the DIN Rail is not screwed on the industrial Ethernet switch please refer to the DIN Rail Mounting section for DIN Rail installation If it is required to wall mount the industrial Ethernet switch please refer to the Wall Mounting section for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power...

Страница 18: ...holes located in the different faces of the device This may not only harm the internal layout but might cause harm to users as well Do not under any circumstance open the device for any reason Please contact your dealer for any repair needed or follow the instructions within the manual Clean the device with dry soft cloth 4 3 Troubleshooting Always verify the right power cord or adapter is being u...

Страница 19: ...blem with the power cord Check for loose power connections power losses or surges at the power outlet Please contact Antaira for technical support service if the problem still cannot be resolved If the industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit please check the system s Ethernet devices configuration or status 14 ...

Страница 20: ... back pressure for half duplex mode Transfer Rate 14 880pps for 10Base T Ethernet 148 800pps for 100Base TX Fast Ethernet Packet Buffer 448Kbits MAC Table Size 1K Port Interface Ethernet Port 8 10 100BaseTx Auto negotiation speed Full Half duplex mode and auto MDI MDI X connection LED Indicators System Power 1 Power 2 and Fault Ethernet Ports Link Activity Protection Network Cable 10Base T 2 pair ...

Страница 21: ...nsumption 2 2 Watts Environmental Limits Operating Temperature STD 10 C to 65 C EOT 40 C to 75 C Storage Temperature 40 C 85 C Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals EMI FCC Part 15 Subpart B Class A CE EN55032 EN61000 6 4 Class A EMS CE EN55035 EN61000 6 2 Class A EN61000 4 2 3 4 5 6 8 Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 Green RoHS Com...

Страница 22: ...ntaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems to Antaira www antaira com support antaira com www antaira eu info antaira eu www antaira com tw info antaira com tw Any changes to this material will be announced on the Antaira website 17 ...

Отзывы: