Antaira Technologies - Industrial Ethernet Switches 

LNX-1604G-SFP Series User Manual V1.1 

 

 

1.2 Package Contents 

  1 - LNX-1604G-SFP (-T): 16-port industrial gigabit unmanaged Ethernet switch with 

12*10/100/ 4*100/1000 SFP slots 

  2 - Wall mounting brackets and screws 

  1 - DC cable –18 AWG & DC jack 5.5x2.1mm 

 

1.3 Safety Precaution 

 

Attention:

 

If the DC voltage is supplied by an external circuit, please use a protection 

device on the power supply input. The industrial Ethernet switch’s 

hardware specs, ports, cabling information, and wiring installation will be 

described within this user manual. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание LNX-1604G-SFP Series

Страница 1: ...ogies Industrial Ethernet Switches LNX 1604G SFP Series User Manual V1 1 i LNX 1604G SFP Series 16 Port Industrial Gigabit Unmanaged Ethernet Switches with 12 10 100 1000Tx 4 100 1000 SFP Slots Version 1 1 User Manual ...

Страница 2: ...rs Notice Copyrights 2018 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the copyright laws Disclaimer Antaira Technologies LLC provides this manual without warranty of any kind expressed or implied including but not limited to the implied warranties of merchantability...

Страница 3: ...ged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution Any changes or modifications not expres...

Страница 4: ... Description 3 2 1 Physical Dimensions 3 2 2 Front Panel 4 2 3 Top View 4 2 4 LED Indicators 5 2 5 Ethernet Ports 6 2 6 Cabling 7 2 7 Wiring the Power Inputs 9 2 8 Wiring the Fault Alarm Contact 9 3 Mounting Installation 10 3 1 DIN Rail Mounting 10 3 2 Wall Mounting 11 4 Hardware Installation 12 4 1 Installation Steps 12 5 Network Applications 13 6 Trouble Shooting 14 7 Technical Specifications 15...

Страница 5: ...N rail as well as wall mountable orientations and provides wide operating temperature range models in STD 10 C to 70 C and EOT 40 C to 75 C This is an industrial grade unit made for any harsh or outdoor networking environment in factory automation ITS power utility and water wastewater treatment plants This unit is also ideal for any other application requiring a high port count solution 1 1 Key F...

Страница 6: ...2 10 100 1000Tx 4 100 1000 SFP slots 2 Wall mounting brackets and screws 1 DC cable 18 AWG DC jack 5 5x2 1mm 1 3 Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be described within this user manual ...

Страница 7: ...ption 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira Technologies LNX 1604G SFP series 16 port industrial gigabit unmanaged Ethernet switch with 12 10 100 1000Tx RJ45 4 100 1000Fx SFP slots W x D x H is 59mm x 99mm x 142mm Figure 2 1 LNX 1604G SFP Series Physical Dimensions ...

Страница 8: ...hows the top panel of the LNX 1604G SFP series switch that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 12 48 VDC Figure 2 2 Front Panel of the LNX 1604G SFP Series Figure 2 3 Top Panel View of LNX 1604G SFP Series LAN 1 12 LED for 1000Mbps LAN 1 12 10 100 1000 RJ45 LAN 1 12 LED for 10 100Mbps Grounding Screw 6 Pin Removal Terminal Block Power Input LED for ...

Страница 9: ...ut 2 is active Off Power input is inactive Fault Red On Power input 1 or 2 is inactive Off Both power input 1 and 2 are active Link Activity SFP Port Green On Connected to the network Flashing Networking is active with 1000Mbps Off Not connected to the network Amber On Connected to the network Flashing Networking is active with 100Mbps Off Not connected to the network LAN Port 1 12 Upper LED Green...

Страница 10: ...atic MDI MDI X operations Users can use straight through cables see figure below for all network connections to PCs servers and other switches or hubs With straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below Table 2 3 shows the 10BASE T 100BASE TX 1000BASE T and MDI MDI X port pin outs Note...

Страница 11: ...nnected with an unshielded twisted pair UTP or shielded twisted pair STP cable The cable must comply with the IEEE 802 3u 100Base TX standard e g Category 5 5e or 6 6e The cable between the equipment and the link partner switch hub workstation etc must be less than 100 meters 328 ft long Note Cable size should be between 18 20 AWG and the torque should be tightened to 5lbs Figure 2 4 Figure 2 5 St...

Страница 12: ...e SFP slot Figure 2 8 shows SFP transceiver module was inserted Second insert the fiber cable of the LC connector into the transceiver as shown below in Figure 2 9 To remove the LC connector from the transceiver please follow the steps shown below 1 Press the upper side of the LC connector from the transceiver and pull it out to release as shown below in Figure 2 10 2 Push down the metal clasp and...

Страница 13: ...k should range between 18 20 AWG 2 8 Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connector as the picture shows below in Figure 2 14 By inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch only and form a normally open circuit An application example for the fault alarm contact is...

Страница 14: ... 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figure 3 2 4 Lightly pull down the bracket on to the rail as shown below in Figure 3 3 5 Check if the bracket is mounted tightly on the rail 6 To remove the industrial Ethernet switch from the rail do...

Страница 15: ...the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall 5 To remove the wall mount bracket do the opposite from the steps above Figure 3 5 below has the dimensions for the...

Страница 16: ...ection for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on For the help on how to wire power please refer to the Wiring the Power Inputs section Please refer to the LED Indicators section for LED light indication 5 Prepare t...

Страница 17: ...Antaira Technologies Industrial Ethernet Switches LNX 1604G SFP Series User Manual V1 1 13 5 Network Applications Figure 5 1 Industrial Ethernet Switch Application Reference ...

Страница 18: ...d 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist o Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose po...

Страница 19: ...C Table Size 8K MAC Address Port Interface Ethernet RJ45 Port 12 10 100 1000Tx auto negotiation speed full half duplex mode and auto MDI MDI X connection Fiber Port 4 100 1000 SFP Slots Fiber Wavelength Refer to SFP Modules LED Indicator Power 1 Power 2 Fault Ethernet Ports On Link Flash data transmitting SFP Link Active Network Cable 10Tx 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 10...

Страница 20: ...EC60068 2 6 Vibration Green RoHS Compliant Compliance EN50121 4 Railway NEMA TS1 TS2 ITS Safety Certificate FCC CE Warranty 5 Years Table 7 1 LNX 1604G SFP Series Technical Specifications Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems to Antaira www antaira com support ant...