![ANTAIRA LNP-800AGH Series Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/antaira/lnp-800agh-series/lnp-800agh-series_hardware-manual_2946680011.webp)
Antaira Technologies - Industrial Ethernet Switches
LNP-800AGH Series - Hardware Manual - v1.0
4 / TP2+
7 / TP3+
4 / TP2+
4 / TP3+
5 / TP2-
8 / TP3-
5 / TP2-
5 / TP3-
6 / TP1-
2 / TP0-
6 / TP1-
6 / TP0-
7 / TP3+
4 / TP2+
7 / TP3+
7 / TP2+
8 / TP3-
5 / TP2-
8 / TP3-
8 / TP2-
Table 2.3 - 1000Base-T RJ45 Pin Assignments
Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair.
2.7 Cabling
Use the four twisted-pair, category 5e, or the above cabling for the RJ45 port connections. The cable between the switch
and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) in length.
The small form-factor pluggable (SFP) is a compact optical transceiver used in optical communications for both
telecommunication and data communication applications.
Caution: Please employ optional optical transceiver (SFP/Fixed Fiber) that complies with IEC-60825-1 and
classified as Class 1 laser product.
Attention: Veuillez utiliser un émetteur-récepteur optique en option (SFP/fibre fixe) conforme à la norme
IEC-60825-1 et classé comme produit laser de classe 1.
2.8 Wiring the Power Inputs
Caution: Please follow the steps below when inserting the power wire.
Attention: Veuillez suivre les étapes ci-dessous lors de l'insertion du câble d'alimentation.
1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-) contacts on the terminal block
connector as shown below in Figure 2.6.
Figure 2.6 - Power Terminal Block
7