LNP-0500G-bt-24 Series User Manual V1.1 

 

 

 

 

 

 

LNP-0500G-bt-24 Series

 

5-Port Industrial Gigabit IEEE 802.3bt PoE++ Unmanaged Ethernet 

Switch, with 4*10/100/1000Tx (90W/Port) and 1*10/100/1000Tx; 

12~55VDC Power Input   

 

User Manual 

Version 1.1 

(June 2020) 

 

 

 

Содержание LNP-0500G-bt-24 Series

Страница 1: ...itches LNP 0500G bt 24 Series User Manual V1 1 i LNP 0500G bt 24 Series 5 Port Industrial Gigabit IEEE 802 3bt PoE Unmanaged Ethernet Switch with 4 10 100 1000Tx 90W Port and 1 10 100 1000Tx 12 55VDC Power Input User Manual Version 1 1 June 2020 ...

Страница 2: ...ers Notice Copyrights 2020 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the copyright laws Disclaimer Antaira Technologies LLC provides this manual without warranty of any kind expressed or implied including but not limited to the implied warranties of merchantabilit...

Страница 3: ...ed to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution Any changes or modifications not express...

Страница 4: ...imensions 3 2 2 Front Panel 4 2 3 Top View 4 2 4 LED Indicators 5 2 5 Dip Switch 6 2 6 Relay Contact Alarm Warning 6 2 7 PoE Port LED Indicators 7 2 8 Ethernet Ports 9 2 9 Cabling 10 2 10 Wiring the Power Inputs 10 2 11 Wiring the Fault Alarm Contact 11 3 Mounting Installation 12 3 1 DIN Rail Mounting 12 3 2 Wall Mounting 14 4 Hardware Installation 15 4 1 Installation Steps 15 5 Trouble Shooting 1...

Страница 5: ...y unregulated voltage This product series provides a reliable hardened Ethernet connection with PoE functions for any outdoor or harsh industrial application environments such as security surveillance ITS traffic monitoring systems oil gas and mining facility management for power utility water wastewater treatment plants and lastly automated production lines in factory automation 1 1 Key Features ...

Страница 6: ...ide 2 Wall mounting brackets and screws 1 DC cable 18 AWG DC jack 5 5x2 1mm 1 3 Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be described within this user manual ...

Страница 7: ... bt 24 Series User Manual V1 1 3 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira Technologies LNP 0500G bt 24 series W x D x H is 54mm x 99mm x 142mm Figure 2 1 LNP 0500G bt 24 Series Physical Dimensions ...

Страница 8: ...with one 6 pin removal terminal block connector for dual DC power inputs 12 55 VDC Figure 2 2 Front Panel of the LNP 0500G bt 24 Series Figure 2 3 Top Panel View of LNP 0500G bt 24 Series LED for PoE Status LED for Link Activity Status 10 100 1000Mbps LED for Link Activity Status 1000Mbps LED for Link Activity Status 10 100Mbps PoE Dip Switch LAN 1 4 10 100 1000Tx LAN 5 10 100 1000Tx Grounding Scr...

Страница 9: ...ive 2 Total PoE loading is 100 PoE Budget 3 PoE over current per port 4 Cable short per port 5 One of the channels in Dual PD fail Off No trigger events occur PoE Load Off Off The actual PoE Consumption of all connected working PDs budget was 50 Blue On The actual PoE Consumption of all connected working PDs budget was 51 70 Red On The actual PoE Consumption of all connected working PDs budget was...

Страница 10: ...Port 1 4 ON OFF Dip Switch 1 Enable Port 1 PoE Function Disable Port 1 PoE Function Dip Switch 2 Enable Port 2 PoE Function Disable Port 2 PoE Function Dip Switch 3 Enable Port 3 PoE Function Disable Port 3 PoE Function Dip Switch 4 Enable Port 4 PoE Function Disable Port 4 PoE Function 2 6 Relay Contact Alarm Warning 2 pin 1 24VDC 1A resistive normal open on 6 pin terminal block The relay contact...

Страница 11: ...the Dual color LED status If the port has recovered from an event user can verify the event from the blinking frequency of the PoE LED 5 seconds as a cycle Power Budget Exceeded Event When the total PoE budget is overload 100 the PoE port of the lowest priority PoE port will be shutdown The PoE LED of the port will act cyclically as below until the port is recovered from the event After the PoE po...

Страница 12: ... the event After the PoE port is recovered from the Cable Short event the PoE LED of the port will act cyclically as below until the event indicator is clear manually AF AT Amber BT Green Dual PD Fail Event When one channel of the connected dual PD is failed the failed channel will be shut down and the active channel will still supply PoE to the connected PD The PoE Port LED will act cyclically as...

Страница 13: ...bling schematics RJ 45 Pin Assignments Table 2 2 Pin Number Assignment 1 Rx 2 Rx 3 Tx 6 Tx All ports on this industrial Ethernet switch support automatic MDI operations Users can use straight through cables see figure below for all network connections to PCs servers and other switches or hubs With straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pin...

Страница 14: ...The cable between the equipment and the link partner switch hub workstation etc must be less than 100 meters 328 ft long 2 10 Wiring the Power Inputs Please follow the below steps to insert the power wire 1 Insert the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 6 2 Tighten the wire clamp screws to prevent the wi...

Страница 15: ... of the terminal block connector as the picture shows below in Figure 2 8 By inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch only and form a normal open circuit An example is shown below in Figure 2 8 Note The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1 to Pin...

Страница 16: ...stallation 3 1 DIN Rail Mounting The DIN Rail is pre installed on the industrial Ethernet switch from the factory If the DIN Rail is not on the industrial Ethernet switch please refer to Figure 3 1 to learn how to install the DIN Rail on the switch Figure 3 1 The Rear Side of the Switch and DIN Rail Bracket ...

Страница 17: ...bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figure 3 2 4 Lightly pull down the bracket on to the rail as shown below in Figure 3 3 5 Check if the bracket is mounted tightly on the rail 6 To remove the industrial Ethernet switch from the rail do the opposite from the abo...

Страница 18: ...2 Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall 5 To remove the wall mount bracket do the opposite from the steps above Below in Figure 3 5 are the dimensi...

Страница 19: ... the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on For the help on how to wire power please refer to the Wiring the Power Inputs section Please refer to the LED Indicators section for LED light indication 5 Prepare the twisted pair straight through category 5 cab...

Страница 20: ...100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist o Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose powe...

Страница 21: ... 1 100 100 1000Tx auto negotiation full half duplex mode and auto MDI MDI X connection PoE Pin Out V V V V for pin 1 2 3 6 V V V V for pin 4 5 7 8 Support Modes Mode A Mode B 4 Pair Mode Dip Switch Control PoE Function by port LED Indicators Per unit Power 1 Power 2 Fault PoE Load P L Per port Speed Link Active PoE On connected to PD devices Relay Contact 24VDC 1A resistive Network Cable 10BaseT 2...

Страница 22: ...MS CE EN55035 EN61000 6 2 Class A IEC61000 4 2 ESD IEC61000 4 3 RS IEC61000 4 4 EFT IEC61000 4 5 Surge IEC61000 4 6 CS IEC61000 4 8 Magnetic Field Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 Green RoHS Compliant Safety FCC CE Warranty 5 Years Table 6 1 LNP 0500G bt 24 Series Technical Specifications Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Ant...