background image

LMX-C602G-SFP-V2 Series

6-Port Industrial Compact Gigabit Light Layer 3 Managed Ethernet Switch,

with 4*10/100/1000Tx and 2*100/1000 SFP Slots

Hardware Manual

Version 1.0

(February 2021)

Содержание LMX-C602G-SFP

Страница 1: ...LMX C602G SFP V2 Series 6 Port Industrial Compact Gigabit Light Layer 3 Managed Ethernet Switch with 4 10 100 1000Tx and 2 100 1000 SFP Slots Hardware Manual Version 1 0 February 2021 ...

Страница 2: ... and fitness for a particular purpose Antaira Technologies LLC may make improvements and or changes to the product and or specifications of the product described in this manual without prior notice Antaira Technologies LLC will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are periodically made to the information contained herein and will be incor...

Страница 3: ...cations radio si l équipement n est pas installé et utilisé conformément aux instructions Cependant il n y a aucune garantie qu aucune interférence ne se produira dans une installation particulière Si cet équipement provoque des interférences nuisibles à la réception radio ou télévision ce qui peut être déterminé en éteignant puis en rallumant l équipement l utilisateur est encouragé à essayer de ...

Страница 4: ...ustrial Grade Managed Ethernet Switches Hardware Manual Version 1 0 February 2021 The manual supports the following models LMX C602G SFP V2 LMX C602G SFP T V2 This document is the current official release hardware manual Please check our website www antaira com for any updated manual or contact us by e mail support antaira com ...

Страница 5: ...rdware Description 4 2 1 Physical Dimensions 4 2 2 Front View Panel 5 2 3 LED Indicators 5 2 4 Reset Button 7 2 5 Ethernet Ports 7 2 6 Cabling 8 2 7 Wiring the Power Inputs 8 2 8 Wiring the Fault Alarm Contact 9 2 9 Grounding Note 10 3 Mounting Installation 12 3 1 DIN Rail Mounting 12 3 2 Wall Mounting 13 4 Hardware Installation 15 4 1 Installation Steps 15 4 2 Maintenance and Service 16 4 3 Troub...

Страница 6: ...range EOT 40 C to 75 C 1 1 Product Hardware Features System Interface and Performance All RJ45 ports support Auto MDI MDI X Function Embedded 4 10 100 1000Tx RJ45 ports and 2 100 1000 SFP slots Store and forward switching architecture 8K MAC address table Supports 9 6Kbytes jumbo frame 4Mbits memory buffer Product Input DC 12 48V redundant with a 6 pin removal terminal block Max current 0 9A Opera...

Страница 7: ...de via TFTP and HTTP Configuration Backup USB Port 1 3 Package Contents LMX C602G SFP T V2 Quick installation guide Wall mounting bracket set with screws DC cable 18AWG DC jack 5 5 x 2 1mm Dust cover set Mini USB B type male to DB9 RS 232 female cable 1 4 Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The in...

Страница 8: ... with the device Shown in Figure 1 1 Étiquettes d avertissement L étiquette d avertissement signifie que vous devez vérifier certaines informations du manuel d utilisation lorsque vous travaillez avec l appareil Illustré à la figure 1 1 Figure 1 1 Caution Label Figure 1 1 Étiquette de mise en garde Figure 1 2 Hot Surface Warning Label Figure 1 2 Étiquette d avertissement de surface chaude 3 ...

Страница 9: ... Switches LMX C602G SFP V2 Series Hardware Manual v1 0 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 64 9mm x 89 8mm x 110mm Figure 2 1 Physical Dimensions 4 ...

Страница 10: ...icators There are LED light indicators located on the front panel of the industrial Ethernet switch that display the power status and network status Each LED indicator has a different color and has its own specific meaning see below in Table 2 1 LED Color Description Power 1 P1 Green On Power Input 1 is active Off Power Input 1 is inactive Power 2 P2 Green On Power Input 2 is active Off Power Inpu...

Страница 11: ...ster is ready Off ERPS Owner Mode is not active Ring R Green On ERPS Ring Network is active Flashing ERPS Ring Network works abnormally or misconfigured Off ERPS Ring Network is not active SFP Port 1 2 Green On Connected to network 1000Mbps Flashing Networking is active Off Not connected to network Amber On Connected to network 100Mbps Flashing Networking is active Off Not connected to network LAN...

Страница 12: ...t Button Functions 2 5 Ethernet Ports RJ45 Ports RJ45 Ports Auto MDI MDI X The RJ45 ports are auto sensing for 10Base T 100Base TX or 1000Base T connections Auto MDI means that the switch can connect to another switch or workstation without changing the straight through or crossover cabling See the figures below for straight through and crossover cabling schematics RJ45 Pin Assignments Crossover C...

Страница 13: ... length The small form factor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communication applications Caution Please employ optional optical transceiver SFP Fixed Fiber that complies with IEC 60825 1 and classified as Class 1 laser product Attention Veuillez utiliser un émetteur récepteur optique en option SFP fibre fixe conforme...

Страница 14: ...rminal block should range between 18 20 AWG Attention Utilisez uniquement des conducteurs en cuivre 125 C serrez à 5 lb Le calibre des fils du bornier doit être compris entre 18 et 20 AWG 2 8 Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connector as the picture shows below in Figure 2 5 By inserting the wires it will detect the fault status includin...

Страница 15: ...n Le calibre des fils du bornier doit être compris entre 12 et 24 AWG Si vous n utilisez qu une seule source d alimentation connectez les broches 1 à 5 et les broches 2 à 6 pour éliminer l alarme de panne de courant 2 9 Grounding Note Grounding and wire routing help limit the effects of noise due to Electromagnetic Interference EMI Run the ground connection from the ground screw to the grounding s...

Страница 16: ...hernet Switches LMX C602G SFP V2 Series Hardware Manual v1 0 Caution Using a shielded cable achieves better electromagnetic compatibility Attention L utilisation d un câble blindé permet une meilleure compatibilité électromagnétique 11 ...

Страница 17: ...he rear side of the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l appareil est de 3 5 pouces livres 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Fi...

Страница 18: ...nde industriel 1 Remove the DIN Rail bracket from the industrial Ethernet switch by loosening the screws 2 Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l ...

Страница 19: ...al Ethernet Switches LMX C602G SFP V2 Series Hardware Manual v1 0 Figure 3 4 Remove DIN Rail bracket from the Switch Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall Mounting Bracket Dimensions 14 ...

Страница 20: ...n If it is required to wall mount the industrial Ethernet switch please refer to the Wall Mounting section for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on For the help on how to wire power please refer to the Wiring the ...

Страница 21: ...er is being used Never use a power supply or adapter with a non compliant DC output voltage or it will burn the equipment Select the proper UTP or STP cable in order to construct the network Use an unshielded twisted pair UTP or shield twisted pair STP cable for RJ45 connections 100Ω Category 5e for 10 100Mbps Also be sure that the length of any twisted pair connection does not exceed 100 meters 3...

Страница 22: ...r mode Power Saving ActiPHY PerfectReach IEEE 802 3az EEE power management Network Redundancy STP RSTP MSTP port trunk with LACP ERPS v1 v2 50ms Configuration Http Https Telnet SSH CLI TFTP SNMP v3 System Diagnostics Dual Image Protection PING PING6 Switch Properties Switch Architecture Back Plane Switching Fabric 12Gbps Priority Queues 8 Protocols IPv4 IPv6 SNMP v1 v2c v3 LLDP LLDP MED HTTP HTTPS...

Страница 23: ...peed Link Active SFP Link Active Protection Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m 1000BaseTX 4 pair UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m Mechanical Characteristics Housing Metal IP40 rated Dimensions 64 9 x 110 x 89 8 mm W x H x D Weight Unit 1 94 lbs Shipping 2 59 lbs Mounting...

Страница 24: ...CE EN55035 EN61000 6 2 Class A EN61000 4 2 3 4 5 6 8 Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 Green RoHS Compliant Certifications FCC CE Warranty 5 Years Table 5 1 Technical Specifications Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems to Antaira ...