ANTAIRA LMX-1202G-SFP Series Скачать руководство пользователя страница 1

 

 

 

LMX-1202G-SFP Series 

12-Port Industrial Gigabit Light Layer 3 Managed Ethernet Switch, with 

10*10/100/1000Tx and 2*100/1000 SFP Slots 

 

Hardware Manual 

 

Version 2.0 

(December 2020) 

 

 

Содержание LMX-1202G-SFP Series

Страница 1: ...LMX 1202G SFP Series 12 Port Industrial Gigabit Light Layer 3 Managed Ethernet Switch with 10 10 100 1000Tx and 2 100 1000 SFP Slots Hardware Manual Version 2 0 December 2020 ...

Страница 2: ...nd fitness for a particular purpose Antaira Technologies LLC may make improvements and or changes to the product and or specifications of the product described in this manual without prior notice Antaira Technologies LLC will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are periodically made to the information contained herein and will be incorpo...

Страница 3: ...ions radio si l équipement n est pas installé et utilisé conformément aux instructions Cependant il n y a aucune garantie qu aucune interférence ne se produira dans une installation particulière Si cet équipement provoque des interférences nuisibles à la réception radio ou télévision ce qui peut être déterminé en éteignant puis en rallumant l équipement l utilisateur est encouragé à essayer de cor...

Страница 4: ... EN 60664 1 Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 140 Conductors suitable for use in an ambient temperature of 105 7 C must be used for the power supply terminal The external grounding conduct shall be at least least 4 mm 2 WARNING EXPLOSION HAZARD Do not disconnect while the circuit is live or unless the area is free of ig...

Страница 5: ...tion 4 2 1 Physical Dimensions 4 2 2 Front View Panel 5 2 3 Top View Panel 6 2 4 LED Indicators 6 2 5 Reset Button 7 2 6 Ethernet Ports 8 2 7 Cabling 9 2 8 Wiring the Power Inputs 9 2 9 Wiring the Fault Alarm Contact 10 2 10 Grounding Note 11 3 Mounting Installation 12 3 1 DIN Rail Mounting 12 3 2 Wall Mounting 13 4 Hardware Installation 15 4 1 Installation Steps 15 4 2 Maintenance and Service 16 ...

Страница 6: ...g temperature models for either a standard temperature range STD 10 C to 70 C or an extended temperature range EOT 40 C to 75 C It also provides high EFT and ESD protection for industrial networking applications such as power utility water wastewater oil gas mining factory automation security surveillance within transportation ITS and any other outdoor or harsh environment 1 1 Product Hardware Fea...

Страница 7: ...gging port based VLAN support IGMP snooping v1 v2 IGMP filtering throttling IGMP query up to 256 group Supports IPv4 IPv6 RMON MIB II port mirroring event syslog DNS NTP SNTP HTTPS SSH SSL TFTP MODBUS TCP for SCADA system integration Port Configuration Status statistics mirroring rate limiting event syslog Event Handling Event notification by Email Cold Warm Start Power Failure Authentication SNMP...

Страница 8: ... d alimentation Les spécifications matérielles les ports les informations de câblage et l installation du câblage du commutateur Ethernet industriel seront décrits dans ce manuel d utilisation Warning Labels The caution label means that you should check certain information on the user manual when working with the device Shown in Figure 1 1 Étiquettes d avertissement L étiquette d avertissement sig...

Страница 9: ...ernet Switch LMX 1202G SFP Series Hardware Manual v2 0 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 54mm x 99mm x 142mm Figure 2 1 Physical Dimensions 4 ...

Страница 10: ...anel Figure 2 2 below shows the front panel of the product series Figure 2 2 Front View Panel WARNING Airflow around the switch must be unrestricted To prevent the switch from overheating there must be the following minimum clearances Top and bottom 2 0 in 50 8 mm Sides 2 0 in 50 8 mm Front 2 0 in 50 8 mm 5 ...

Страница 11: ...d network status Each LED indicator has a different color and has its own specific meaning see below in Table 2 1 6 LED Color Description P1 Green On Power Input 1 is active Off Power Input 1 is inactive P2 Green On Power Input 2 is active Off Power Input 2 is inactive Fault Green On Power Input 1 or 2 is active Off Power off Red On Fault alarm is set and the condition is inactive Master Green On ...

Страница 12: ...N Port 1 10 Upper LED Green On Connected to network 1000Mbps Flashing Networking is active Off Not connected to network LAN Port 1 10 Lower LED Green On Connected to network 10 100Mbps Flashing Networking is active Off Not connected to network SFP Port 11 12 Green On Connected to network 1000Mbps Flashing Networking is active Off Not connected to network Amber On Connected to network 100Mbps Flash...

Страница 13: ...Table 2 2 10 100Base T X RJ45 Pin Assignments Table 2 3 1000Base T RJ45 Pin Assignments Note and signs represent the polarity of the wires that make up each wire pair 8 Crossover Cable Straight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Crossover Cable Straight Through Cable P...

Страница 14: ...cations Caution Please employ optional optical transceiver SFP Fixed Fiber that complies with IEC 60825 1 and classified as Class 1 laser product Attention Veuillez utiliser un émetteur récepteur optique en option SFP fibre fixe conforme à la norme IEC 60825 1 et classé comme produit laser de classe 1 2 8 Wiring the Power Inputs Caution Please follow the steps below when inserting the power wire A...

Страница 15: ...AWG Attention Utilisez uniquement des conducteurs en cuivre 125 C serrez à 5 lb Le calibre des fils du bornier doit être compris entre 18 et 20 AWG 2 9 Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connector as the picture shows below in Figure 2 8 By inserting the wires it will detect the fault status including power failure or port link failure man...

Страница 16: ... alimentation connectez les broches 1 à 5 et les broches 2 à 6 pour éliminer l alarme de panne de courant 2 10 Grounding Note Grounding and wire routing help limit the effects of noise due to Electromagnetic Interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices The grounding screw symbol is shown below in Figure 2 9 Figure 2 9 Groundi...

Страница 17: ...rear side of the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l appareil est de 3 5 pouces livres 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figur...

Страница 18: ...e industriel 1 Remove the DIN Rail bracket from the industrial Ethernet switch by loosening the screws 2 Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l ap...

Страница 19: ...rial Ethernet Switch LMX 1202G SFP Series Hardware Manual v2 0 Figure 3 4 Remove DIN Rail bracket from the Switch Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall Mounting Bracket Dimensions 14 ...

Страница 20: ...t switch If the DIN Rail is not screwed on the industrial Ethernet switch please refer to the DIN Rail Mounting section for DIN Rail installation If it is required to wall mount the industrial Ethernet switch please refer to the Wall Mounting section for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Pow...

Страница 21: ...ght cause harm to users as well Do not under any circumstance open the device for any reason Please contact your dealer for any repair needed or follow the instructions within the manual Clean the device with dry soft cloth 4 3 Troubleshooting Always verify the right power cord or adapter is being used Never use a power supply or adapter with a non compliant DC output voltage or it will burn the e...

Страница 22: ...0 Please contact Antaira for technical support service if the problem still cannot be resolved If the industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit please check the system s Ethernet devices configuration or status 17 ...

Страница 23: ...mode Power Saving ActiPHY PerfectReach IEEE 802 3az EEE power management Network Redundancy STP RSTP MSTP port trunk with LACP ERPS v1 v2 50ms Configuration Http Https Telnet SSH CLI TFTP SNMP v3 System Diagnostics Dual Image Protection PING PING6 Switch Properties Switch Architecture Back Plane Switching Fabric 24 0Gbps Protocols IPv4 IPv6 SNMP v1 v2c v3 LLDP LLDP MED HTTP HTTPS SSHv2 telnet DHCP...

Страница 24: ...ts Speed Link Active Fixed Fiber Link Active Protection Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m 1000BaseTX 4 pair UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m Mechanical Characteristics Housing Metal IP30 protection Dimensions 54 x 142 x 99 mm W x H x D Weight Unit 1 98 lbs Shipping 2 87 lbs Mo...

Страница 25: ...changes to this material will be announced on the Antaira website 20 System Power Consumption 15 Watts Environmental Limits Operating Temperature STD 10 C to 65 C EOT 40 C to 75 C Storage Temperature 40 C 85 C Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals EMI FCC Part 15 Subpart B Class A CE EN55032 EN61000 6 4 Class A EMS CE EN55024 EN61000 6 2 Class A EN61000 4 2 3 4 5 6 ...

Отзывы: