Antaira Industrial Ethernet Switches 

LMP-0501G-SFP Series User Manual V1.0 

 

 

 

 

 

 

LMX-0501G-SFP Series

 

5-Port Industrial Gigabit Managed Ethernet Switch, with 

4*10/100/1000Tx and 1*100/1000 SFP Slot, 

12~48VDC Power Input 

 

 

 

 

 

 

 

 

 

 

User Manual 

Version 1.1 

 

 

 

Содержание LMX-0501G-SFP Series

Страница 1: ...Ethernet Switches LMP 0501G SFP Series User Manual V1 0 i LMX 0501G SFP Series 5 Port Industrial Gigabit Managed Ethernet Switch with 4 10 100 1000Tx and 1 100 1000 SFP Slot 12 48VDC Power Input User...

Страница 2: ...e Copyrights 2018 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the...

Страница 3: ...to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into a...

Страница 4: ...4 2 3 Top View 4 2 4 LED Indicators 5 2 5 Ethernet Ports 6 2 6 Cabling 7 2 7 Wiring the Power Inputs 10 2 8 Wiring the Fault Alarm Contact 11 3 Mounting Installation 12 3 1 DIN Rail Mounting 12 3 2 Wa...

Страница 5: ...guration 33 5 6 3 MSTI Status 35 5 6 4 MSTI Configuration 36 5 7 802 1Q VLAN 38 5 7 1 802 1Q VLAN settings 38 5 7 2 802 1Q VLAN Settings 39 5 8 IGMP Snooping 39 5 8 1 IGMP Settings 40 5 8 2 IGMP Snoop...

Страница 6: ...ult Alarm 51 5 13 MAC Table 52 5 13 1 MAC Address Table 52 5 13 2 MAC Table Configuration 52 5 14 Maintenance 53 5 14 1 Upgrade 53 5 14 2 Reboot 54 5 14 3 Default 54 5 15 Configuration 54 5 15 1 Save...

Страница 7: ...IP30 rated and DIN rail mountable design and provides wide operating temperature range models in STD 10 C to 70 C and EOT 40 C to 75 C and it also provided high EFT and ESD protection for any industr...

Страница 8: ...erature Standard operating temperature models 10 C to 70 C Extended operating temperature models 40 C to 75 C Case Installation IP 30 protection metal housing Installation in pollution degree to envir...

Страница 9: ...n 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira s LMX 0501G SFP series 5 Port industrial managed Ethernet switch with 4 10 100 1000Tx and 1 100 1000 SFP slot 12 48V...

Страница 10: ...rial managed Ethernet switches is shown below in Figure 2 2 2 3 Top View Figure 2 3 below shows the top panel of the LMX 0501G SFP series switch that is equipped with one 6 pin removal terminal block...

Страница 11: ...ve Fault Green On System is ready Off System is booting Red On Fault Alarm Off System is in normal state Owner Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active Ring Gree...

Страница 12: ...et switch support automatic MDI MDI X operation Users can use straight through cables see figure below for all network connections to PCs servers other switches or hubs With straight through cable pin...

Страница 13: ...schematics for straight through and crossover The following figures show the 10 100 1000 Ethernet RJ 45 pin outs Figure 2 4 Straight through Cable Schematic Figure 2 5 Crossover Cable Schematic Figure...

Страница 14: ...n 100 meters 328 ft long Fiber segment port 5 dual rate 100 1000 SFP slot The small form factor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication...

Страница 15: ...or from the transceiver please follow the steps shown below Press the upper side of the LC connector from the transceiver and pull it out to release as shown below in Figure 2 12 Push down the metal c...

Страница 16: ...res into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 6 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figur...

Страница 17: ...picture shows below in Figure 2 8 By inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch only and forma normally open circuit An...

Страница 18: ...Rail bracket on the rear side of the industrial Ethernet switch 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch i...

Страница 19: ...he wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch 4 Use the hook holes at the corn...

Страница 20: ...tion for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then...

Страница 21: ...with advanced management features that allow users to manage the switch from anywhere on the network through any Internet browser such as Internet Explorer version 9 0 or above is recommended Firefox...

Страница 22: ...Click Login button then the main status page of the Web Console will appear as below Figure 5 2 The online image of the switch will display the real time ports connection status 5 2 Basic Setting 5 2...

Страница 23: ...name label to describe this PoE Managed Switch System Location Factory Default blank Users can use this field to insert The physical location of this switch e g telephone closet 3rd floor The maximum...

Страница 24: ...DHCP fails and the configured IP address is zero DHCP will retry If DHCP fails and the configured IP address is non zero DHCP will stop and the configured IP settings will be used The DHCP client will...

Страница 25: ...k Apply button to save changes 5 2 4 System Time Terms Value Description Local Time Users can define the switch s local time or click Sync with browser button to have local time setup automatically Se...

Страница 26: ...n provides the current port status 5 3 2 Port Configuration Users can assign or insert a value label for each port under each Port Name box enable or disable each port function state the speed duplex...

Страница 27: ...bel for each port s identification Status Enable or disable a port Speed Duplex User can set the bandwidth of each port as Auto negotiation 100 full 100 half 10 full 10 half mode Flow Control Support...

Страница 28: ...naged Ethernet switches In order to provide users with the flexibility and compatibility when there are any existing switches that contains the standard ERPS protocol Ethernet Ring Protection Switchin...

Страница 29: ...tatus Below Figure 5 18 shows the network redundancy ring status with the Ethernet Ring Protection Switch ERPS protocol 5 5 2 ERPS Configuration Below Figure 5 19 shows the ERPS configuration interfac...

Страница 30: ...efined as Normal node All node roles have the ability to block the port if the link attach to the port is failed and disconnected Ring ID ERPS ring ID ranges from 1 to 239 Ring ID distinguishes differ...

Страница 31: ...isabled due to only one protocol is exclusive running within a switch Below are the steps to disable RSTP or MSTP Step 1 Login the switch with a web browser Step 2 Open the RSTP Configuration page und...

Страница 32: ...he loop avoidance mechanism ensures the traffic flows on all but the RPL ring link In order to achieve the loop avoidance mechanism ITU T G 8032 defines three roles in ERPS which are RPL Owner Node RP...

Страница 33: ...re three major roles are required to be configured within the ERPS configuration Figure 5 20 RPL configured Architecture Caution Before enabling any ERPS protocols on any of the Ring Nodes please DO N...

Страница 34: ...point Port 1 was chosen as example Step 2 Choose a specific port from the dropdown box next to ring port 1 then set it as Normal from the dropdown box next to Role which locates below ring port 1 At t...

Страница 35: ...nd choose a specific port number under Ring Port 0 and set it as the Normal node by clicking the dropdown box of Role then set another specific port number under Ring Port 1 as the Neighbor node as sh...

Страница 36: ...p the rest of the managed switches Role of both Ring Port 0 and 1 as Normal Node as shown above in Figure 5 23 Please be sure no duplicate port number has been chosen within a managed switch s ERPS ri...

Страница 37: ...oose the biggest MAC as the blocking node However the user is still required to enable the RRPS protocol and assign a dedicated port number for each uplink port under Ring Port 0 and 1 but there is no...

Страница 38: ...and essentially creates a cascading effect away from the root bridge where each designated bridge proposes to its neighbors to determine if it can make a rapid transition Another extension of RSTP is...

Страница 39: ...Manual V1 1 33 5 6 1 RSTP Status Figure 5 26 shows the RSTP algorithm results 5 6 2 RSTP Configuration Users can enable disable the RSTP function and set the parameters for each port Figure 5 26 RSTP...

Страница 40: ...seconds a bridge waits without receiving STP configuration messages before attempting a reconfiguration Path Cost 0 200000000 Enter a value from 1 through 200000000 to define the path cost for the oth...

Страница 41: ...ocol is applied separately for a set of VLAN s instead of the whole network Different root switches and different STP parameters can be individually configured for each MSTI So one link can be active...

Страница 42: ...MAC address of the bridge switch Revision User can insert the value from 0 65535 MTSI Instance Instance No VLAN Group There are 1 15 instance number user can insert which VLAN Group info into the bel...

Страница 43: ...efine the path cost value from 1 through 200000000 to the other bridge from this transmitting bridge at the specified port Priority User can decide which port should be blocked by priority in LAN by s...

Страница 44: ...ttings Tagged based VLAN is an IEEE 802 1Q specification standard and it is possible to create a VLAN across devices from different switch venders IEEE 802 1Q VLAN uses a technique to insert a tag int...

Страница 45: ...ticast group memberships When IGMP snooping is enabled in a switch it analyzes all the IGMP packets between hosts connected to the switch and multicast routers in the network When a switch receives an...

Страница 46: ...5 8 1 IGMP Settings Terms Value Description IGMP Protocol Check the box to enable or disable IGMP Snooping Querier Switch will be IGMP querier or not There should have the existing one and only one IG...

Страница 47: ...c is always unpredictable and the only basic assurance that can be offered is the best effort traffic delivery To overcome this challenge Quality of Service QoS is applied throughout the network This...

Страница 48: ...DSCP or Cos When select DSCP only trusted DSCP Differentiated Services Code Point values are mapped to a specific QoS class and drop precedence level DPL Frames with untrusted DSCP values are treated...

Страница 49: ...scription Cos Value 0 7 User can assign each port a CoS value from 0 to 7 According to the IEEE 802 1p user can define each CoS value in 4 priority queues from Low to Normal Medium and High Click Appl...

Страница 50: ...the IP header The most significant 6 bits of the ToS field are fully decoded into 64 possibilities and the singular code that results is compared against the corresponding bit in the IPv4 ToS priority...

Страница 51: ...Mode Enable Port Mirroring function by check the box Go To Interface User can use the dropdown box to choose the destination port as Port to mirror on feature Monitor Direction User can select the mo...

Страница 52: ...rk performance find and solve network problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP 5 11...

Страница 53: ...Enable SNMP Trap Enable SNMP Trap function by check the box Trap Destination IP User could insert the Server IP address as Trap Destination IP info Community User can release the SNMP to public for re...

Страница 54: ...er to monitor the remote site network and device statuses 5 12 1 Syslog Setting The SYSLOG is a protocol to transmit event notification messages across networks Terms Value Description SYSLOG Mode Dis...

Страница 55: ...Apply button on the right bottom corner of the interface Then the system event logs will display within the SYSLOG LIST window The SYSLOG LIST will contain up to 5 pages of system event log informati...

Страница 56: ...up the mail server IP address Sender E mail Address Set up the email account to send the alert Mail Subject The subject of the mail Authentication Check the box to enable the Authentication function...

Страница 57: ...he same time After the event selection users can click the Apply button to save changes 5 12 5 Fault Alarm When any selected fault event has occurred the fault LED of the switch s front panel will lig...

Страница 58: ...MAC address is to be forwarded through a given potential transmission port 5 13 1 MAC Address Table 5 13 2 MAC Table Configuration Users can check the checked box of each port and insert the port s V...

Страница 59: ...atest firmware from Antaira s website and store it within their local PC server or USB drive Terms Value Description FIRMWARE UPGRADE User can click the Choose File button to select the latest firmwar...

Страница 60: ...evice through the built in USB port Users can use the USB port feature to execute the Auto Load function to boot the switch s configuration that has been saved within the USB storage device or users c...

Страница 61: ...rms Value Description CONFIGURATION MANAGEMNET Backup Configuration By click the Backup button it allows user to backup the switch configuration setting to local PC or server Upload Configuration User...

Страница 62: ...of Upload If the folder or filename does not exist system will return error If it succeeds system will reboot Ex file1 folder file2 5 15 3 Auto Load Backup Terms Value Description USB Auto Load Select...

Страница 63: ...s can use console or telnet to management switch by CLI CLI Management by RS 232 Serial Console 115200 8 none 1 none Before configuring by an RS 232 serial console use an RJ45 to DB9 F cable to connec...

Страница 64: ...Antaira Industrial Ethernet Switches LMX 0501G SFP Series User Manual V1 1 58 Step 2 Input a name for the new connection Step 3 Select to use COM port number...

Страница 65: ...1 59 Step 4 The COM port property settings are as follows 115200 for Bits per second 8 for Data bits None for Parity 1 for Stop bits and none for Flow control Step 5 The Console login screen will app...

Страница 66: ...e is as below IP Address 192 168 1 254 Subnet Mask 255 255 255 0 Default Gateway none User Name admin Password admin Follow the steps below to access the console via Telnet Step 1 Telnet to the IP add...

Страница 67: ...onment temperature configure admin username admin configure admin password admin configure IP boot host dhcp configure ip address ip_addr ip_mask configure ip default gateway ip_router configure ip na...

Страница 68: ...tp sync month configure no ntp sync weekly configure show ntp client enable configure show ntp client timeserver configure show clock timezone configure show ntp sync schedule enable configure show nt...

Страница 69: ...e port tag qinq configure vlan group group_num group_portlist configure switchport pvid vlan_id interface switchport filter tagged untagged interface switchport provider interface switchport ethertype...

Страница 70: ...032 no port0 g8032 no port1 g8032 no ring id g8032 no timer hold off g8032 no timer guard g8032 no timer wtr g8032 show ethernet ring g8032 status g8032 show ethernet ring g8032 brief g8032 show ether...

Страница 71: ...e admin edge interface no spanning tree stp interface show spanning tree mode configure show spanning tree priority configure show spanning tree forward time configure show spanning tree hello time co...

Страница 72: ...event smtp cold start enable configure event smtp warm start enable configure event smtp authentication failure enable configure event smtp erps change enable configure event smtp interface INTERFACE...

Страница 73: ...vent syslog cold start configure show event syslog warm start configure show event syslog authentication failure configure show event syslog erps change configure show event syslog interface INTERFACE...

Страница 74: ...re no smtp authentication username configure no smtp authentication password configure no smtp receive 1 2 3 4 configure show smtp state configure show smtp sender configure show smtp subject configur...

Страница 75: ...trap v3 user user_ID configure snmp trap v3 level auth noauth priv configure snmp trap v3 engine ID engineID configure snmp trap v3 auth md5 sha PASSWORD configure snmp trap v3 encryption des aes PASS...

Страница 76: ...stination configure QoS qos queue schedule strict wrr configure qos map cos priority_type to tx queue queue configure qos map dscp priority_type to tx queue queue configure qos trust cos dscp interfac...

Страница 77: ...nfigure no igmp snooping last member count configure no igmp snooping last member interval configure no igmp snooping querier configure no igmp snooping fast leave interface show igmp snooping mdb con...

Страница 78: ...ure terminal copy startup config usb path Fill in the folder and filename behind the copy startup config usb command Ex file1 folder file2 3 CLI enable configure terminal copy usb startup config path...

Страница 79: ...in the folder and filename behind the copy usb startup config command Ex file1 folder file2 5 CLI enable configure terminal Syslog mode usb or all Select USB or ALL it can auto save waning file to US...

Страница 80: ...802 1ad Stacked VLAN Q in Q IEEE 802 1p QoS CoS Protocol for Traffic Prioritization Switch Protocol CSMA CD IGMPv1 v2 SNMPv1 v2 TFTP SNTP SMTP RARP Syslog Data Process Store and Forward Transfer Rate...

Страница 81: ...l block Power Consumption 10 Watts Environmental Limits Operating Temperature STD 10 to 70 C 14 to 158 F EOT 40 to 75 C 40 to 167 F Storage Temperature 40 C 85 C 40 F 185 F Ambient Relative Humidity 5...