2.10 Wiring the Power Inputs
Caution: Please follow the steps below when inserting the power wire.
Attention: Veuillez suivre les étapes ci-dessous lors de l'insertion du câble d'alimentation.
1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-) contacts on the
terminal block connector as shown below in Figure 2.11.
Figure 2.11 - Power Terminal Block
2.
Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in Figure 2.12.
Figure 2.12 - Power Terminal Block
Caution:
Only use copper conductors, 125°C, tighten to 5 lbs.
The wire gauge for the terminal block should range between 18~20 AWG.
Attention:
Utilisez uniquement des conducteurs en cuivre, 125°C, serrez à 5 lb.
Le calibre des fils du bornier doit être compris entre 18 et 20 AWG.