After the PoE port is recovered from the Dual PD Fail event, the PoE LED of the port will act cyclically as
below until the event indicator is clear manually:
Figure 2.10 - PoE Dual PD Recovering LED Sequence
**IEEE 802.3af/at: Amber
**IEEE 802.3bt: Green
*Note:
1. The system will automatically retry to recover from the event failure every 20 seconds.
2. To clear the warning PoE Indicator of the recovered port, please replug the port cable or reopen the PoE
function of the port via DIP switch (
≥ 2 sec.)
2.5 DIP Switch
The 4-pin DIP switch on the front panel of the Ethernet switch works as the PoE controller for PoE port
1~4.
Table 2.2 - DIP Switch Functions
2.6 Relay Contact Alarm Warning
2-pin 1*24VDC@1A resistive normal open on 6-pin terminal block.
The relay contact alarm will be triggered when anyone of the listed events occurs.
Key trigger event 1: Power 1 or Power 2 is inactive
Key trigger event 2: PoE total loading > 100% PoE output budget
Key trigger event 3: PoE over current per port
Key trigger event 4: Cable short per port
Key trigger event 5: One of the channels in Dual PD fail
10
ON
OFF
DIP Switch 1
Enable Port 3 PoE function
Disable Port 3 PoE function
DIP Switch 2
Enable Port 4 PoE function
Disable Port 4 PoE function
DIP Switch 3
Enable Port 5 PoE function
Disable Port 5 PoE function
DIP Switch 4
Enable Port 6 PoE function
Disable Port 6 PoE function