4.2 Maintenance and Service

If the device requires servicing of any kind, the user is required to disconnect and remove it from its mounting.

The initial installation should be done in a way that makes this as convenient as possible.

Voltage / Power lines should be properly insulated as well as other cables. Be careful when handling them so as

to not trip over.

Do not under any circumstance insert foreign objects of any kind into the heat dissipation holes located in

the different faces of the device. This may not only harm the internal layout, but might cause harm to users

as well.

Do not under any circumstance open the device for any reason. Please contact your dealer for any repair

needed or follow the instructions within the manual.

Clean the device with dry soft cloth.

4.3 Troubleshooting

Always verify the right power cord or adapter is being used. Never use a power supply or adapter with a

non-compliant DC output voltage or it will burn the equipment.

Diagnosing LED Indicators: To assist in identifying problems, the switch can be easily monitored with the LED

indicators which help to identify if any problems exist.

Please refer to the LED Indicators section for LED light indication.

If the power indicator LED does not turn on when the power cord is plugged in, the user may have a problem with

the power cord. Check for loose power connections, power losses or surges at the power outlet.

Please contact Antaira for technical support service if the problem still cannot be resolved.

If the industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot

transmit, please check the system’s Ethernet devices’ configuration or status.

Содержание LMP-1600G-M12-67-110 Series

Страница 1: ...110 Series 16 Port Industrial M12 IP67 Waterproof Gigabit PoE Light Layer 3 Managed Ethernet Switch with 16 10 100 1000Tx M12 Connectors X Coded 30W Port 24 110VDC Power Input Hardware Manual Version...

Страница 2: ...s of the product described in this manual without prior notice Antaira Technologies LLC will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are period...

Страница 3: ...rf rences nuisibles la r ception radio ou t l vision ce qui peut tre d termin en teignant puis en rallumant l quipement l utilisateur est encourag essayer de corriger les interf rences par une ou plus...

Страница 4: ...hernet Switches LMP 1600G M12 67 110 Series Hardware Manual v1 0 This document is the current official release hardware manual Please check our website www antaira com for any updated manual or contac...

Страница 5: ...cription 9 2 1 Physical Dimensions 9 2 2 Front View Panel 10 2 3 LED Indicators 11 2 4 Reset to Default 12 2 5 Ethernet Ports 12 2 6 USB Port 14 2 7 Console Port 14 2 8 Power Inputs 15 2 9 Relay Conta...

Страница 6: ...scheduling and PoE output limit function to set up PoE output duration and watt at will LMP 1600G M12 67 110 Series is an M12 IP67 PoE industrial gigabit Ethernet switch that meets the high reliabilit...

Страница 7: ...ress and Egress broadcast storm control Diffserv IEEE 802 1q VLAN tagging port based VLAN support IGMP snooping v1 v2 v3 IGMP filtering throttling IGMP query up to 1024 group Supports IPv4 IPv6 RMON M...

Страница 8: ...l entr e d alimentation Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage du commutateur Ethernet industriel seront d crits dans ce manuel d utilisation...

Страница 9: ...itches LMP 1600G M12 67 110 Series Hardware Manual v1 0 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 166 2mm x 295m...

Страница 10: ...ira Technologies Industrial Ethernet Switches LMP 1600G M12 67 110 Series Hardware Manual v1 0 2 2 Front View Panel Figure 2 2 below shows the front panel of the product series Figure 2 2 Front View P...

Страница 11: ...system is ready and works fine No events are occurring Red Flashing Firmware upgrading On System booting or configured event happens Master Green On ERPS Owner Mode Ring Master is ready Off ERPS Owne...

Страница 12: ...t Step 2 Restart the power Step 3 The switch will start rebooting with the port LEDs flashing Step 4 When the status LED turns Green the process is completed Step 5 Remove the reversed console cable 2...

Страница 13: ...le category 5e or the above cabling for M12 port connections The cable between the Ethernet switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long Minimum Wire...

Страница 14: ...is for configuration backup restore M12 connector M12 4 Pin A Coded female connector Pinouts Function 1 DN 2 VBUS 3 GND 4 DP Table 2 3 USB port pinouts 2 7 Console Port It is an M12 5 Pin A Coded fem...

Страница 15: ...steps below to insert the power wire Step 1 Insert the positive and negative power wires into the power connector on the industrial Ethernet switch with Power 1 V1 V1 and Power 2 V2 V2 Step 2 Tighten...

Страница 16: ...conditions below 1 No event after reboot 2 No event after reset the switch A connection of relay contact for fault alarm is shown below in Figure 2 5 Figure 2 5 Wiring the relay contact for fault ala...

Страница 17: ...current 8mA Table 2 7 Specification of DI As described in the Relay Contact section if the fault status total output power over device s PoE power budget or any one of PoE ports over 30 Watts happens...

Страница 18: ...tches loses power Ethernet ports P8 and P16 will bypass the power lost Ethernet switch to prevent the network from disconnecting Take Figure 2 7 for example if Switch B has power failure the bypass fu...

Страница 19: ...p 1 Prepare 4 screws for mounting the switch to a wall Note Recommended use of the M5 screws Step 2 Based on the Figure 2 1 Physical Dimensions which is shown the positions of 4 screw holes on the lef...

Страница 20: ...Antaira Technologies Industrial Ethernet Switches LMP 1600G M12 67 110 Series Hardware Manual v1 0 Figure 3 2 Position of the screw holes...

Страница 21: ...ox 2 To hang the industrial Ethernet switch on a wall please refer to the Mounting Installation section 3 Power on the industrial Ethernet switch and then the power LED light will turn on If you need...

Страница 22: ...or follow the instructions within the manual Clean the device with dry soft cloth 4 3 Troubleshooting Always verify the right power cord or adapter is being used Never use a power supply or adapter w...

Страница 23: ...rking Scheduler mode Power Saving ActiPHY PerfectReach IEEE 802 3az EEE power management Network Redundancy STP RSTP MSTP port trunk with LACP ERPS v1 v2 50ms Configuration Http Https Telnet SSH CLI T...

Страница 24: ...UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m 1000BaseTX 4 pair UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m Mechanical Char...

Страница 25: ...Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 Green RoHS Compliant Certifications FCC CE Warranty 5 Years Table 5 1 Technical Specifications Antaira Customer Service and Support Antair...

Отзывы: