2.3 LED Indicators

There are LED light indicators located on the front panel of the industrial Ethernet switch that display the power status and

network status. Each LED indicator has a different color and has its specific meaning, see below in

Table 2.1

.

LED

Color

Description

P1

Green

On

Power Input 1 is active

Off

Power Input 1 is inactive

P2

Green

On

Power Input 2 is active

Off

Power Input 2 is inactive

Status

Green

On

The system is ready and works fine. No events are occurring.

Red

Flashing

Firmware upgrading

On

System booting or configured event happens

Master

Green

On

ERPS Owner Mode (Ring Master) is ready

Off

ERPS Owner Mode is not active

Ring

Green

On

Ring Network is active

Flashing

ERPS Ring works abnormally or misconfigured

Off

Ring Network is not active

PoE Load

Off

Off

PoE Load ≤ 50%

Blue

On

PoE Load 51 - 70%

Red

On

PoE Load 71 - 90%

Red

Flashing

PoE Load 91 - 100%

Note: The Max. PoE output of this switch is 120 Watts.

LAN Port 1~16

Green

On

Connected to the network, 1000Mbps

Flashing

Networking is active

Off

Not connected to the network

Amber

On

Connected to the network, 10/100Mbps

Flashing

Networking is active

Off

Not connected to the network

Содержание LMP-1600G-M12-67-110 Series

Страница 1: ...110 Series 16 Port Industrial M12 IP67 Waterproof Gigabit PoE Light Layer 3 Managed Ethernet Switch with 16 10 100 1000Tx M12 Connectors X Coded 30W Port 24 110VDC Power Input Hardware Manual Version...

Страница 2: ...s of the product described in this manual without prior notice Antaira Technologies LLC will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are period...

Страница 3: ...rf rences nuisibles la r ception radio ou t l vision ce qui peut tre d termin en teignant puis en rallumant l quipement l utilisateur est encourag essayer de corriger les interf rences par une ou plus...

Страница 4: ...hernet Switches LMP 1600G M12 67 110 Series Hardware Manual v1 0 This document is the current official release hardware manual Please check our website www antaira com for any updated manual or contac...

Страница 5: ...cription 9 2 1 Physical Dimensions 9 2 2 Front View Panel 10 2 3 LED Indicators 11 2 4 Reset to Default 12 2 5 Ethernet Ports 12 2 6 USB Port 14 2 7 Console Port 14 2 8 Power Inputs 15 2 9 Relay Conta...

Страница 6: ...scheduling and PoE output limit function to set up PoE output duration and watt at will LMP 1600G M12 67 110 Series is an M12 IP67 PoE industrial gigabit Ethernet switch that meets the high reliabilit...

Страница 7: ...ress and Egress broadcast storm control Diffserv IEEE 802 1q VLAN tagging port based VLAN support IGMP snooping v1 v2 v3 IGMP filtering throttling IGMP query up to 1024 group Supports IPv4 IPv6 RMON M...

Страница 8: ...l entr e d alimentation Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage du commutateur Ethernet industriel seront d crits dans ce manuel d utilisation...

Страница 9: ...itches LMP 1600G M12 67 110 Series Hardware Manual v1 0 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 166 2mm x 295m...

Страница 10: ...ira Technologies Industrial Ethernet Switches LMP 1600G M12 67 110 Series Hardware Manual v1 0 2 2 Front View Panel Figure 2 2 below shows the front panel of the product series Figure 2 2 Front View P...

Страница 11: ...system is ready and works fine No events are occurring Red Flashing Firmware upgrading On System booting or configured event happens Master Green On ERPS Owner Mode Ring Master is ready Off ERPS Owne...

Страница 12: ...t Step 2 Restart the power Step 3 The switch will start rebooting with the port LEDs flashing Step 4 When the status LED turns Green the process is completed Step 5 Remove the reversed console cable 2...

Страница 13: ...le category 5e or the above cabling for M12 port connections The cable between the Ethernet switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long Minimum Wire...

Страница 14: ...is for configuration backup restore M12 connector M12 4 Pin A Coded female connector Pinouts Function 1 DN 2 VBUS 3 GND 4 DP Table 2 3 USB port pinouts 2 7 Console Port It is an M12 5 Pin A Coded fem...

Страница 15: ...steps below to insert the power wire Step 1 Insert the positive and negative power wires into the power connector on the industrial Ethernet switch with Power 1 V1 V1 and Power 2 V2 V2 Step 2 Tighten...

Страница 16: ...conditions below 1 No event after reboot 2 No event after reset the switch A connection of relay contact for fault alarm is shown below in Figure 2 5 Figure 2 5 Wiring the relay contact for fault ala...

Страница 17: ...current 8mA Table 2 7 Specification of DI As described in the Relay Contact section if the fault status total output power over device s PoE power budget or any one of PoE ports over 30 Watts happens...

Страница 18: ...tches loses power Ethernet ports P8 and P16 will bypass the power lost Ethernet switch to prevent the network from disconnecting Take Figure 2 7 for example if Switch B has power failure the bypass fu...

Страница 19: ...p 1 Prepare 4 screws for mounting the switch to a wall Note Recommended use of the M5 screws Step 2 Based on the Figure 2 1 Physical Dimensions which is shown the positions of 4 screw holes on the lef...

Страница 20: ...Antaira Technologies Industrial Ethernet Switches LMP 1600G M12 67 110 Series Hardware Manual v1 0 Figure 3 2 Position of the screw holes...

Страница 21: ...ox 2 To hang the industrial Ethernet switch on a wall please refer to the Mounting Installation section 3 Power on the industrial Ethernet switch and then the power LED light will turn on If you need...

Страница 22: ...or follow the instructions within the manual Clean the device with dry soft cloth 4 3 Troubleshooting Always verify the right power cord or adapter is being used Never use a power supply or adapter w...

Страница 23: ...rking Scheduler mode Power Saving ActiPHY PerfectReach IEEE 802 3az EEE power management Network Redundancy STP RSTP MSTP port trunk with LACP ERPS v1 v2 50ms Configuration Http Https Telnet SSH CLI T...

Страница 24: ...UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m 1000BaseTX 4 pair UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m Mechanical Char...

Страница 25: ...Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 Green RoHS Compliant Certifications FCC CE Warranty 5 Years Table 5 1 Technical Specifications Antaira Customer Service and Support Antair...

Отзывы: