LMP-1202M-SFP Series Hardware Manual V1.0 

ii 

 

 

 

© Copyright 2019 Antaira Technologies, LLC 

All Rights Reserved 
This document contains information, which is protected by copyright. Reproduction, adaptation or translation 
without prior permission is prohibited, except as allowed under the copyright laws. 

 

Trademark Information 

 

Antaira is a registered trademark of Antaira Technologies, LLC, Microsoft Windows and the Windows logo are the 
trademarks of Microsoft Corp. NetWare is the registered trademark of Novell Inc. WMM and WPA are the 
registered trademarks of Wi-Fi Alliance. All other brand and product names are trademarks or registered 
trademarks of their respective owners. 

 

Notice: 

Copyrights © 2019 by Antaira Technologies, LLC. All rights reserved. Reproduction, adaptation, or 

translation without prior permission of Antaira Technologies, LLC is prohibited, except as allowed under the 
copyright laws. 

 

 

Disclaimer 

Antaira Technologies, LLC provides this manual without warranty of any kind, expressed or implied, including but 
not limited to the implied warranties of merchantability and fitness for a particular purpose. Antaira Technologies, 
LLC may make improvements and/or changes to the product and/or specifications of the product described in this 
manual, without prior notice. Antaira Technologies, LLC will not be liable for any technical inaccuracies or 
typographical errors found in this guide. Changes are periodically made to the information contained herein and 
will be incorporated into later versions of the manual. The information contained is subject to change without prior 
notice. 

Содержание LMP-1202M-SFP

Страница 1: ...1002G SFP Series User Manual V1 0 i LMP 1202M SFP Series LMP 1202M SFP LMP 1202M SFP T 12 Port Industrial PoE Gigabit Managed Ethernet Switch with 8 10 100Tx 30W Port 2 10 100 1000Tx RJ45 and 2 100 10...

Страница 2: ...ers Notice Copyrights 2019 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed u...

Страница 3: ...ch can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna I...

Страница 4: ...all only be used in an area of not more than pollution degree 2 as defined in EN 60664 1 Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more tha...

Страница 5: ...Precaution 3 2 Hardware Description 4 2 1 Physical Dimensions 4 2 2 Front Panel 5 2 3 Top View 5 2 4 LED Indicators 6 2 5 Reset Button 7 2 6 Ethernet Ports 7 2 7 Cabling 8 2 8 Wiring the Power Inputs...

Страница 6: ...Switch protocol that has a 50ms network recovery time The advanced network filtering and security functions such as IGMP VLAN QoS SNMP RMON ModbusTCP and 802 1X HTTPS SSH SSL increase determinism and...

Страница 7: ...ts support Auto MDI Function Embedded 8 10 100Tx PSE 30W Port RJ45 Ports 2 10 100 1000Tx RJ45 and 2 100 1000 SFP Slots Store and forward switching architecture 8K MAC address table Power line EFT prot...

Страница 8: ...1mm 1 5 Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports...

Страница 9: ...n 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira s LMP 1202M SFP series 12 port industrial PoE managed Ethernet switches with 8 10 100Tx PSE 30W Port 2 10 100 1000Tx...

Страница 10: ...equipped with one 6 pin removal terminal block connector for dual DC power inputs 48 55VDC Figure2 3 Top Panel View of LMP 1202M SFP Series Console Port LED for Power 1 Power 2 Fault Master and Ring 6...

Страница 11: ...s not active Ring Green On Ring Network is active Off Ring Network is not active LAN Port 1 8 Left LED Green On Connected to network 10 100Mbps Flashing Networking is active Off Not connected to netwo...

Страница 12: ...rossover cabling See the figures below for straight through and crossover cabling schematics RJ 45 Pin Assignments Pin Number Assignment 1 Rx 2 Rx 3 Tx 6 Tx Table 2 3 RJ45 Pin Assignments Note The and...

Страница 13: ...t in length Caution Please employ optional optical transceiver SFP that complies with IEC 60825 1 and classified as Class 1 laser product The small form factor pluggable SFP is a compact optical trans...

Страница 14: ...ector to the Transceiver To remove the LC connector from the transceiver please follow the steps shown below 1 Press the upper side of the LC connector from the transceiver and pull it out to releasea...

Страница 15: ...V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 12 Figure 2 12 Power Terminal Block 2 Tighten the wire clamp screws to prevent the wires from loosening as shown...

Страница 16: ...alarm contact is shown below in Figure 2 14 Caution The wire gauge for the terminal block should range between 12 24AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to elimi...

Страница 17: ...ide of the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket...

Страница 18: ...ews 2 Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Caution The torque...

Страница 19: ...g installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light w...

Страница 20: ...0 SFP slots Standards IEEE 802 3 10Base T 10Mbit s Ethernet IEEE 802 3u 100Base Tx 100Base Fx Fast Ethernet IEEE 802 3ab 1000Base Tx Gigabit Ethernet IEEE 802 3z Gigabit Fiber IEEE 802 3x Flow Control...

Страница 21: ...1000BaseTX UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m Mechanical Characteristics LED Indicator Power Unit P1 Green P2 Green fault Red Ethernet port Link active Green 1000Mbps SFP Link active Gre...

Страница 22: ...ort Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems to Antaira www antaira com support antaira com www antaira...