2.8 Wiring the Power Inputs
Caution:
Please follow the steps below when inserting the power wire.
Attention:
Veuillez suivre les étapes ci-dessous lors de l'insertion du câble d'alimentation.
1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-)
contacts on the terminal block connector as shown below in
Figure 2.6
.
2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in
Figure 2.7
.
Caution:
•
Only use copper conductors, 125
°
C, tighten to 5 lbs.
•
The wire gauge for the terminal block should range between 18~20 AWG.
Attention:
•
Utilisez uniquement des conducteurs en cuivre, 125°C, serrez à 5 lb.
•
Le calibre des fils du bornier doit être compris entre 18 et 20 AWG.
Figure 2.7
Power Terminal Block
Figure 2.6
Power Terminal Block