2.10 Wiring the Fault Alarm Contact
The fault alarm contact is in the middle of the terminal block connector as the picture shows below in
Figure 2.8
. By inserting the wires, it will detect the fault status including power failure or port link failure
(managed industrial switch only), and form a normal open circuit. An example is shown below in
Figure
2.8
.
Figure 2.8 - Wiring the Fault Alarm Contact
Caution:
The wire gauge for the terminal block should range between 12 ~ 24 AWG.
If only using one power source, jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault
alarm.
Attention:
Le calibre des fils du bornier doit être compris entre 12 et 24 AWG.
Si vous n'utilisez qu'une seule source d'alimentation, connectez les broches 1 à 5 et les broches
2 à 6 pour éliminer l'alarme de panne de courant.