http://www.ansoncorp.com
Read
the manual before usage and keep for
future reference.
User
Manual
1. Product Features
1.1 Independent and concise, configurable by the
panel without connecting to computer
1.2 Three modes of access: Card alone, Card plus
Password and Password alone.
1.3 Facilitated with a capacity of 800 cards with
one password.
1.4 Supportive for disassemble-preventative alarm.
1.5 Exit button input and door bell input.
1.6 All data can be kept for 10 years with power off.
1.7 Input with wave absorption function.
1.8 Supportive for electronic locks working in
power-on mode or power-off mode.
1.9 Product Size: L×W×H (mm): 117×117×21.
3. Ensure power cable is ready before put
the system on, screw bolt from bottom
4. Wiring Diagram
2. Electric Parameters
3. Installation Procedures
1. Disassemble the back cover
Uncover
the
back from
bottom
2. Put the back cover agianst wall and
screw tight the bolts
GND +12V COM NO NC GND SW BELL
V+
V-
NO
COM
NC
EM
Lock
①
①
②
②
③
③
+
B
-
B
+
12V GND
+
12 GND
AC220V
AC 220V 50Hz
The default administrator password is 123456,
defualt user password is 8888.
5.1 Entering configuration
Dial “*” and input administrator password then
dial “#” key. If the password is correct, the
buzzer will innitiate one long buzz and the
POWER light will be off while the MODE light
on. The buzzer will buzz twice shortly and the
system will exit Editing Mode if the password
is inccorrect.
5.2 Change administrator password
In the Editing Mode(after finish the procedures
in 5.1), Dial “0”
→
input a new 6-digit adminis-
trator password
Dial “#”
reinput the new
password Dial “#” again. If the passwords in-
put are inconsistent, the buzzer will innitiate
two short buzzing and exit the Editing Mode.
5.3 Change user password
Dial “1”
in-
put a 4-digit new password
Dial “#”
rein-
put the new password
Dial “#” again.
5.4 Adding card information
5.4.1 Adding a single card
→
→
Finish the procedures in 5.1
→
→
→
→
→
5. Configuration
6. Instruction for LED Lights
7. Instruction for Buzzer
Buzzer
Anti
-
dis-
assemble
Button
Working Voltage:DC9-15V
Static Current:
≤
70mA
Lock Current:
≤
3000mA
Reader Distance:5-15 cm
Type of Card:EM card or compatiable EM Card
Working Temperature:-10
℃
t
o 50
℃
Relative Humidity:10%-90%
Controller Power
Back of Controller
Exit Button
Note:
Disconnect all
powers before
wiring, the po-
wer can be swi-
tched on with
all components
are connected
correctly.
Finish the procedures in 5.1
→
Dial “2”
→
input
the 3-digit number of the card (for example,
033, 256 etc.)
→
read the card
→
dial “#” again
5.4.2 Adding multiple cards
Finish the procedures in 5.1
→
Dial“2”
→
input
the 3-digit number of the first card
→
read the
second card (for example, read 10 cards at
one time)
→
dial “#” again (one 3-digit number
corresponds to one card. In case of adding
multiple cards, the 3-digit number for the se-
cond card will add 1 automatically, the number
ranges from 000-799 )
5.5 Deletion of card(after finish the procedures in
5.1Dial)
5.5.1 Delete all cards: Dial “3”
→
input 0000
→
dial “#”
5.5.2 Delete the cards read: Dial “3”
→
read the
card
→
dial “#”
5.5.3 Delete lost card: Dial “3”
→
input the num-
ber of the lost card
→
dial “#”
5.6 Door-open mode setup(after finish the proce-
dures in 5.1)
5.6.1 Open with card: Dial 400
→
d
ial “#”
5.6.2 Open with card and password: Dial 401
→
dial “#”
5.6.3 Open with card or password: Dial 402
→
dial “#”
Default is 402: open with card or password
5.7 Door-open time setup
Finish the procedures in 5.1
→
Dial “5”
→
dial
a 2-digit number (00-99)
→
dial “#”.
The default door-open time is 3 seconds.
5.8 anti-disassemble alarm setup
Finish the procedures in 5.1
→
Dial 600
→
dial
“#” close anti-disassemble alarm output, dial
601
→
dial “#” permit anti-disassemble alarm.
Default setup forbid the anti-disassemble alarm.
5.9 Reset administrator password
In case the newly assigned administrator pass-
word is lost, the following procedures can be
carried out to recover the default password
from factory(i.e. 123456)
5.9.1 Switch off the power and uninstall the device
5.9.2 Switch on the power again and connect No.1
and No.4 finger On Jp2 which is located on the
back circuit board of the device(Please note
only connect No.1 and No.4, Not No.1, No.2,
No.3 and No.4). Jp2 locate at the bottom of the
circuit board and can be seen and operated
without opening the back cover.
Valid Card/Password Input
Long buzzing once
Invalid Card Input Short buzzing twice
Invalid Password Input Short buzzing twice
Press Exit Button Long buzzing once
Correct Input Long buzzing once
Incorrect Input Short buzzing twice
Anti
-
disassemble
Alarm Continuous buzzing
Card Overflow Short buzzing twice
Deleted or Invalid Card Short buzzing twice
Type of Occasion Mode of Buzzer
Normal Mode No
buzzing
Entering Configuration Mode Long buzzing once
Normal Mode
Configuration Mode
Valid Card/Password
Invalid Card
Invalid Password
Press Exit Button
Correct Input
Incorrect Input
Disassemble
Alarm
Red
Green Orange
POWER
OK MODE
Type of Alarm
On
Off
Off
On
On
Off
Off
On
On
Off
Off
On
Off
Off
On
Off
Off
Off
Off
On
Off
Off
Off
Off
On
Off
Off
Sustained Effort for the Better
Special Note:
1. The interval of each operation is 15s while the in-
terval of each key-push is 3s.
2. Password consists of numbers from 0 to 9.
3. Each operation should be ended by “#”.
Integrated Access