A-5 Technical Reference
Test Records
A-46
PN: 10370-10386 Rev. B
MG362x1A MM
MG362x1A
Firmware Revision:
Operator:
Serial Number:
Date:
Options:
Power Level Accuracy Test (40.0 GHz)
For MG36241A
(26 of 27)
Power Sensor:
For Models with K connectors, use power sensor N5532B-550 with 2.4mm to 2.92 mm (K) adapter (P/N 11904D)
Set L1
Measured Power
(dBm)
Offset Value
(dB)
Final Value
(dBm)
Specification
(dBm)
See TDS
(11410-00928)
Measurement
Uncertainty
(dB)
+25 dBm
0.34
+20 dBm
0.22
+15 dBm
0.22
+10 dBm
0.22
+5 dBm
0.22
+0 dBm
0.22
Calculated Offset
N/A
N/A
N/A
–5 dBm
0.016
–10 dBm
0.019
–15 dBm
0.022
–20 dBm
0.024
–25 dBm
0.027
–30 dBm
0.030
–35 dBm
0.032
–40 dBm
0.035
–45 dBm
0.038
–50 dBm
0.040
–55 dBm
0.043
–60 dBm
0.052
–65 dBm
0.054
–70 dBm
0.057
–75 dBm
0.059
–80 dBm
0.083
–85 dBm
0.132
–90 dBm
0.225
–95 dBm
0.355
–100 dBm
0.513
Содержание Rubidium MG362 1A Series
Страница 12: ...Contents 10 PN 10370 10386 Rev B MG362x1A MM ...
Страница 16: ...1 9 ESD Requirements General Information 1 4 PN 10370 10386 Rev B MG362x1A MM ...
Страница 30: ...2 6 RF Deck Assemblies Functional Description 2 14 PN 10370 10386 Rev B MG362x1A MM ...
Страница 66: ...3 11 FM and Phase Modulation Calibration Calibration 3 36 PN 10370 10386 Rev B MG362x1A MM ...
Страница 164: ...4 26 Pulse Modulation Tests with the 86100C Oscilloscope Performance Verification 4 98 PN 10370 10386 Rev B MG362x1A MM ...
Страница 292: ...B 5 Self Test Messages Instrument Messages B 8 PN 10370 10386 Rev B MG362x1A MM ...
Страница 293: ......