MT9090A/MU909011A Network Master User’s Guide
4-37
9.
Connect the next fiber to be tested and press the
Start key
to continue.
Real Time Testing
Real Time test mode provides a quick “real-time” view of the
initial trace information. In this mode, trace data is not
continually averaged, but is stopped and restarted after each
screen update. Real Time mode enables optimization of fiber
connections at or near the OTDR connector, as the trace
display shows the effects of making changes to the
connections.
To start a Real Time test:
•
With the Trace View screen displayed, press
Start
Real Time
(
F1
). The legend on the softkey changes
to
Stop Real Time
and the test begins.
Figure 4-24: Real Time test in progress