4-3 Sample Procedure
Channel Scanner (Option 27)
4-2
PN: 10580-00349 Rev. M
Spectrum Analyzer MG
4-3
Sample Procedure
The power can be scanned using a signal standard and channel numbers, or by entering a
start frequency, frequency step size, and bandwidth. The channels can be customized using
the Scan Custom List or Custom Setup.
The following procedure demonstrates a common channel scanner setup.
1.
Press the
Scanner
main menu key to activate the Scanner menu.
2.
Press the
Scan Channels
submenu key.
3.
Press the
Signal Standard
submenu key, then select the
CDMA US PCS
signal standard.
4.
Press the
Number of Channels
submenu key and enter
20
.
5.
Press the
Amplitude
main menu key and set the
Reference Level
and
Scale
so that the
power of all the channels is displayed on the screen.
6.
Press the
Measurements
main menu key to activate the Measurement menu.
7.
If needed, press the
Display
submenu key to select the
Graph
format.
8.
Press the
Max Hold
submenu key and select
On
or
5 sec
.
9.
If needed, press the
Channel
Units
submenu key to select the
Channel
setting.
10.
Press the
Power Display
submenu key and choose
Max
to display the maximum
measured power for each channel.
11.
Press the
Color Code
submenu key and select
Dual
to display the measurements in
dual colors.
Содержание BTS Master
Страница 103: ...Spectrum Analyzer 2 35 Trace Menu Spectrum Analyzer MG PN 10580 00349 Rev M 2 91 Figure 2 78 Trace Info...
Страница 246: ...6 6 Coverage Mapping Menu Coverage Mapping Option 431 6 24 PN 10580 00349 Rev M Spectrum Analyzer MG...
Страница 278: ...7 21 Marker Menu AM FM PM Analyzer Option 509 7 32 PN 10580 00349 Rev M Spectrum Analyzer MG...
Страница 282: ...8 2 Bias Tee Menu Bias Tee Option 10 8 4 PN 10580 00349 Rev M Spectrum Analyzer MG...
Страница 295: ......