Interference Analyzer (Option 25)
3-17 Sweep Menu
Spectrum Analyzer MG
PN: 10580-00349 Rev. M
3-77
Trigger Source Menu
Key Sequence:
Shift
>
Sweep
(
3
) key
> Triggering
> Source
Free Run:
In this mode, a new sweep is started immediately upon
completion of an old sweep. No trigger event is required to initiate a sweep.
External (TTL):
A TTL signal applied to the External Trigger BNC input
connector causes a single sweep. After the sweep is complete, the resultant
trace is displayed until the next trigger signal is received.
Video:
This mode uses Video power as the trigger source. The trigger level
is set using the Level key in the
. The trigger is based on
the measured signal level. If no signal reaches or exceeds the trigger level,
no trace will be displayed on the screen.
IF Power
(MS2720T Only)
:
This mode uses IF power level as the trigger
source. The power level is set using the Level key in the
The trigger is based on the measured signal level. If no signal reaches or
exceeds the trigger level, no trace will be displayed on the screen.
Back:
Returns to the
“Triggering Menu” on page 3-76
Figure 3-71.
IA Triggering Source Menu
Trigger Source
Back
External (TTL)
Video
Free
Run
IF Power
Содержание BTS Master
Страница 103: ...Spectrum Analyzer 2 35 Trace Menu Spectrum Analyzer MG PN 10580 00349 Rev M 2 91 Figure 2 78 Trace Info...
Страница 246: ...6 6 Coverage Mapping Menu Coverage Mapping Option 431 6 24 PN 10580 00349 Rev M Spectrum Analyzer MG...
Страница 278: ...7 21 Marker Menu AM FM PM Analyzer Option 509 7 32 PN 10580 00349 Rev M Spectrum Analyzer MG...
Страница 282: ...8 2 Bias Tee Menu Bias Tee Option 10 8 4 PN 10580 00349 Rev M Spectrum Analyzer MG...
Страница 295: ......