![Anritsu BTS Master MT8221B Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/anritsu/bts-master-mt8221b/bts-master-mt8221b_user-manual_2945251017.webp)
General Information
1-5 Preventive Maintenance
BTS Master UG
PN: 10580-00207 Rev. E
1-3
Measurements may be stored in internal memory or in a USB Flash drive. Stored
measurements can be downloaded to a PC by using the included USB and Ethernet cables.
After being stored, a graphic trace can then be displayed, scaled, or enhanced in Master
Software Tools with markers and limit lines. Historical graphs can be overlaid with current
data by using the PC mouse in a drag
-
and
-
drop fashion. The underlying data can be extracted
and used in spreadsheets or for other analytical tasks.
1-5
Preventive Maintenance
BTS Master preventive maintenance consists of cleaning the unit and inspecting and
cleaning the RF connectors on the instrument and on all accessories. Clean the BTS Master
with a soft, lint-free cloth that is dampened with water or with water and a mild cleaning
solution.
Clean the RF connectors and center pins with a cotton swab dampened with denatured
alcohol. Visually inspect the connectors. The fingers of N(f) connectors and the pins of N(m)
connectors should be unbroken and uniform in appearance. If you are unsure whether the
connectors are good, gauge the connectors to confirm that their dimensions are correct.
Visually inspect the test port cables. The test port cable should be uniform in appearance, not
stretched, kinked, dented, or broken.
Note
For USB storage, not all after-market USB drives are compatible with the
instrument. Many drives come with a second partition that contains proprietary
firmware. This partition must be removed. Only one partition is allowed. Refer to
the individual manufacturer for instructions on how to remove it. Some drives can
be made to work by reformatting them using the FAT32 format.
Caution
To avoid damage to the display or case, do not use solvents or abrasive cleaners.
Содержание BTS Master MT8221B
Страница 1: ...BTS Master User Guide MT8221B and MT8222B The High Performance Handheld Base Station Analyzer ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 24: ...1 12 Secure Environment Workplace General Information 1 10 PN 10580 00207 Rev E BTS Master UG ...
Страница 46: ...2 13 Firmware Overview Instrument Overview 2 22 PN 10580 00207 Rev E BTS Master UG ...
Страница 54: ...3 8 PN 10580 00207 Rev E BTS Master UG ...
Страница 88: ...7 8 PN 10580 00207 Rev E BTS Master UG ...
Страница 94: ...8 5 Updating Instrument Firmware Master Software Tools 8 6 PN 10580 00207 Rev E BTS Master UG ...
Страница 95: ...Master Software Tools 8 5 Updating Instrument Firmware BTS Master UG PN 10580 00207 Rev E 8 7 ...
Страница 96: ...8 5 Updating Instrument Firmware Master Software Tools 8 8 PN 10580 00207 Rev E BTS Master UG ...
Страница 97: ...Master Software Tools 8 5 Updating Instrument Firmware BTS Master UG PN 10580 00207 Rev E 8 9 ...
Страница 98: ...8 5 Updating Instrument Firmware Master Software Tools 8 10 PN 10580 00207 Rev E BTS Master UG ...
Страница 114: ...C 8 PN 10580 00207 Rev E BTS Master UG ...
Страница 118: ...Index 4 PN 10580 00207 Rev E BTS Master UG ...
Страница 119: ...Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 P N 10000 00000 Revision Prelim Printed March 2014 ...
Страница 152: ...2 18 Other Menus GSM GPRS EDGE Signal Analyzer 2 18 PN 10580 00234 Rev V 3GPP MG ...
Страница 196: ...3 18 Other Menus W CDMA HSPA Signal Analyzer 3 44 PN 10580 00234 Rev V 3GPP MG ...
Страница 224: ...4 16 Other Menus TD SCDMA HSPA Signal Analyzer 4 28 PN 10580 00234 Rev V 3GPP MG ...
Страница 272: ...5 19 Other Menus LTE Signal Analyzer 5 48 PN 10580 00234 Rev V 3GPP MG ...
Страница 338: ...7 5 Coverage Mapping Menu LTE and TD LTE Coverage Mapping 7 16 PN 10580 00234 Rev V 3GPP MG ...
Страница 354: ...8 4 W CDMA EMF Menu EMF Option 444 8 16 PN 10580 00234 Rev V 3GPP MG ...
Страница 360: ...Index 4 PN 10580 00234 Rev V 3GPP MG ...
Страница 361: ......