A.2 BERT
A-9
A
ppe
ndi
x A
A.2.2 Pulse Pattern Generator
Table A.2.2-1 PPG
Item
Specifications
Data Output*
1
Number of output
MP2110A-011:
1 (Data Out,
Data
Out)*
2
MP2110A-012:
2 (Data Out,
Data
Out)*
2
MP2110A-014:
4 (Data Out,
Data
Out)*
2
Amplitude
Range
0.1 to 0.8 Vp-p / 0.01 V resolution (Single-ended)
0.2 to 1.6 Vp-p / 0.02 V resolution (Differential)
Accuracy
±20 mV ±20% for settings*
3
Data Crossing
50%
Accuracy
±10%*
3,
*
4
Tr/Tf
typ. 15 ps*
3,
*
4
(20-80%)
max. 17 ps*
3,
*
4
(20-80%)
Jitter
MP2110A-011,
MP2110A-012
MP2110A-014
typ.
max.
typ.
max.
Jitter (RMS) *
3,
*
4,
*
5,
*
6
600 fs
900 fs
600 fs*
8
,
900 fs*
8
,
900 fs*
9
1200 fs*
9
Intrinsic RJ (RMS)
*
3,
*
4,
*
5,
*
7
400 fs
600 fs
400 fs*
8
,
600 fs*
8
,
800 fs*
9
1000 fs*
9
Output ON/OFF
ON/OFF switching
Data/XData Skew
±8 ps max.*
3,
*
4
Connector
K, female
Data Format
NRZ
Test Pattern
PRBS:
2^7–1, 2^9–1, 2^15–1, 2^23–1, 2^31–1
Auxiliary pattern:
1/2 Clock Pattern, 1/16 Clock Pattern
Pattern Invert
ON/OFF
External ATT Factor 0 to 30 dB, 1 dB resolution
Able to display the relative value of Data output and Data output.
Error Addition
Single
*1: These are measured in the MP2110A sampling scope (with
MP2110A-024).
The clock output is used for the external trigger (Trigger) of the
sampling scope.
*2: These can be output separately.
*3: When bit rate is set to 25.78125 Gbit/s.
*4: When amplitude is set to 0.3 Vp-p.
*5: These are measured in 25±5 degree Celsius.
*6: Test pattern is PRBS 2^31–1.
*7: Test pattern is 1/16 Clock Pattern.
Содержание BERTWave Series
Страница 26: ...VI...
Страница 74: ...Chapter 1 Outline 1 48...
Страница 166: ...Chapter 4 Screen Operation 4 24...
Страница 210: ...Chapter 6 How to Operate Sampling Scope 6 16 Figure 6 2 2 4 Switching Graph Display...
Страница 237: ...6 2 Explanation of Windows 6 43 6 How to Operate Sampling Scope Figure 6 2 4 9 Measure Dialog Box Equalizer Tab...
Страница 239: ...6 2 Explanation of Windows 6 45 6 How to Operate Sampling Scope Figure 6 2 4 10 Measure Dialog Box Mask Test Tab...
Страница 246: ...Chapter 6 How to Operate Sampling Scope 6 52 Figure 6 2 6 2 Time Dialog Box CRU Tab When MP2110A 054 is installed...
Страница 309: ...6 9 Measuring Waveform 6 115 6 How to Operate Sampling Scope Figure 6 9 5 1 Marker Display...
Страница 322: ...Chapter 6 How to Operate Sampling Scope 6 128...
Страница 377: ...8 6 Adding an Option License 8 11 8 Maintenance 10 Click System Menu System Information and confirm the added option...
Страница 380: ...Chapter 8 Maintenance 8 14 7 Click Reinstall Windows 8 Click Yes...
Страница 432: ...Appendix A Specifications A 36...
Страница 457: ...D 3 Sampling Oscilloscope D 11 Appendix D 26G 53G CRU MP2110A 055 Table D 3 7 CRU Output Sensitivity Pass Fail...
Страница 458: ...Appendix D Performance Test Record Form D 12...