1)Before changing bits from BK Series screwdriver, make sure the Forward / Reverse switch stays at   

“OFF”position. 

The screwdriver must be unplugged. 

2)

 

To avoid damaging the housing of screwdriver, do not allow chemicals get in touch with housing of screwdriver. Ex.: Acetone, 

benzene, thinner, trichloroethylene ketone, and other similar chemicals. 

3) Use screwdriver carefully, do not drop or abuse. It would be better to use with the spring balancer. If without spring balancer, 

you can place the screwdriver in the suspension rack. 

4) Assemble / disassemble bits : Only use fingers pull up the bit sleeve to release bits. ; Place back the bit sleeve to lock the bit 

holder. 

Attention : Make sure the power is off, or the Forward / Reverse switch stays at “OFF”position when assemble or disassemble 

bits. 

5)Connect the plug to the socket. Attention : It will cause an electric shock if the plug or the hand is wet. 

6)You can adjust the torque by the torque adjuster ring. The number on the scale is not equal to the real torque, please refer to our 

torque range chart, or test the torque by our torque meter. 

Attention : Hi gear Do not adjust the torque setting higher than 8 on the torque scale. 

         Lo gear Do not adjust the torque setting higher than 4 on the torque scale. 

7) a)MY9-0206L Series Trigger Start Type screwdriver : When fasten a screw, please set Forward / Reverse   

Switch to “Forward”. 

(If the screw is reversed-thread screw, please set Forward / Reverse switch to “Reverse”.) Point at the place of the bit and the 

screw, press the trigger to start; When torque reaches user’s setting, the clutch will shut out automatically, the power will shut 

off and the motor breaks immediately, the screwdriver stop running. 

b) MY9-0206P Series Push Start Type screwdriver : When fasten a screw, please set Forward / Reverse switch to “Forward”. 

(If the screw is reversed-thread screw, please set Forward / Reverse switch to “Reverse”.) Point at the place of the bit and the 

screw, push down the screwdriver to start; When torque reaches user’s setting, the clutch will shut out automatically, the 

power will shut off and the motor breaks immediately, the screwdriver stop running. 

8) Trigger Start Type screwdriver : When loosen a fastened screw, please set Forward / Reverse switch to “Reverse”. 

(If the screw is reversed-thread screw, please set Forward / Reverse switch to “Forward”.) 

Follow the above operation, after loosening the screw, release the trigger to stop. 

Push Start Type screwdriver : When loosen a fastened screw, please set Forward / Reverse switch to “Reverse” 

(If the screw is reversed-thread screw, please set Forward / Reverse switch to “Forward”.) 

Follow the above operation, after loosening the screw, stop pushing the screwdriver to stop. 

9) Operation frequency: The original setting of the frequency is 1 sec on / 3 sec off. The number of screw fastened is about 15 pcs. 

Over frequently using makes the motor overheated and damage to screwdriver.   

Enough heat-dissipation is good for screwdriver. 

 

 

 

 

 

 

10) Do not use this screwdriver to fasten wooden screws.

 

11) Do not operate the Forward / Reverse switch when the motor is running. 

12) Whenever a screwdriver is not being used, move the Forward / Reverse switch to the “OFF” position and unplug the screwdriver. 

13) Keep staying aware. 

Pay attention on your work, check safety measures and every part is workable before using screwdrivers, to make sure 

screwdrivers can work under original design function. 

14) Use cable for the external counter and I/O box is shield cable for avoidance of electrical interference 

  Use Anti-interference lines. 

 

 

 

 

 

Slow speed (rpm)  operation frequency  Slow speed (rpm)  operation frequency  Slow speed (rpm)  operation frequency 

900 

1.0 ON 3.0 OFF 

600 

1.0 ON 3.0 OFF 

300 

2.0 ON 5.0 OFF 

850 

1.0 ON 3.0 OFF 

550 

2.0 ON 5.0 OFF 

250 

2.0 ON 5.0 OFF 

800 

1.0 ON 3.0 OFF 

500 

2.0 ON 5.0 OFF 

200 

2.0 ON 5.0 OFF 

750 

1.0 ON 3.0 OFF 

450 

2.0 ON 5.0 OFF 

150 

2.0 ON 5.0 OFF 

700 

1.0 ON 3.0 OFF 

400 

2.0 ON 5.0 OFF 

100 

2.0 ON 5.0 OFF 

650 

1.0 ON 3.0 OFF 

350 

2.0 ON 5.0 OFF 

 

 

          Operations Cautions 

Slow speed Duty Cycle Conversion (for reference) 

Based on 1000 rpm, 1 second ON/3 seconds OFF. For example, the duty cycle for 350rpm,1000-350=650

 

650/1000%=65% 

ON= 1*1.65= 1.65

OFF =3*1.65 =4.95 (rounded value) =2 seconds ON / 5 seconds OFF 

This tool is intended for a duty cycle of 2.0 sec on, 5.0 sec off. 

Содержание MYTORQ MY9-0206L

Страница 1: ...gh torque series For safety consideration please collaborate it with Auxiliary Arm KP AUXA2 DC TYPE Automatic Non Carbon Brush Series ANLIDAR INDUSTRIAL CO LTD http www anlidar com Y2F182A 3E 002 MY9 0206L MY9 0206LF MY9 0309L MY9 0612L MY9 0206P MY9 0206PF MY9 0309P MY9 0612P ...

Страница 2: ...tion enclosed Read all these instructions before placing tool in service or operation this tool and save these instructions It is the responsibility of the employer to place the information in this manual into the hands of the operator Failure to observe the following warnings could result in injury When using electric tools Basic safety precautions should always be followed to reduce the risk of ...

Страница 3: ...equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries Rubber gloves and non skid footwear are recommended when working outdoors c Avoid accidental starting Ensure the switch is in the off position before plugging in Carrying power tools with your finger on the switch or plugging in power tools that have the sw...

Страница 4: ...epair person using only identical replacement parts this will ensure that the safety of the power tool is maintained Additional information shall be provided a Instruction for putting into use 1 Setting up or fixing power tool in a stable position as appropriate for power tools which can be mounted on a support 2 Assembly 3 Connection to power supply cable fuse socket type and earthing requirement...

Страница 5: ...t important task a user Periodically depends on the working condition and circumstance for maintaining a good function the user has to check the grounding condition every 3 6 months by an electric meter and following simple steps Set the Ohm meter to level R 100 Ohm Touching 2 test rods together and reset the meter to 0 Using the Red rod to touch the Grounding wire on the Plug of controller s cord...

Страница 6: ...ically the power will shut off and the motor breaks immediately the screwdriver stop running 8 Trigger Start Type screwdriver When loosen a fastened screw please set Forward Reverse switch to Reverse If the screw is reversed thread screw please set Forward Reverse switch to Forward Follow the above operation after loosening the screw release the trigger to stop Push Start Type screwdriver When loo...

Страница 7: ... and reach the torque that you had set The tool will stopped automatically To reset the tool by releasing the lever to the original position or releasing the bit From the screw head To return the screw set the changeover switch to R position Hi Lo Switch When the TR0206 Series rotating speed needs to be changed set up the switch to Hi for the fastest rotation and set up the switch to Lo for slowes...

Страница 8: ...labels Replace any damaged label 1 The use of other than genuine MYTORQ replacement parts may Result in decreased tool performance and increased maintenance and may invalidate all warranties 2 All repairs and maintenance of this tool and its word must be performed by an authorized service center 3 Anlidar is not responsible for customer modification of tools for applications on which Anlidar was n...

Страница 9: ...MY9 0206LF MY9 0309L MY9 0612L MY9 0206P MY9 0206PF MY9 0309P MY9 0612P Input voltage DC DC 40V Power Consumption 150 150 150 150 Torque N m hard joints 2 6 2 6 3 9 6 12 soft joints 80 2 4 8 2 4 8 3 7 2 4 9 6 Repeatable Torque Accuracy 5 Torque Adjustment Stepless Unloaded Rotation Speed R p m 10 1000 2200 1000 880 Screw Size Dia Machine screw mm 4 0 5 0 4 0 5 0 5 0 6 0 8 Tapping screw mm 4 4 4 5 ...

Страница 10: ...of screwdriver The clamping torque of screw itself is different from the clamped conditions Understand the correlation between clamping torque values and the torque checker values perform the torque control properly 1 Please read the operation caution carefully before using our screwdriver and follow the safety information to use this power supplier 2 This model screwdriver must work with 6PIN pow...