Owner’s Manual
Models:
LL-20K, LL-45K, LL-65K, LL-80K, LL-100K, LL-140K
IN LINE TAP-VALVE
BARBED T FITTING
™
Страница 1: ...Owner s Manual Models LL 20K LL 45K LL 65K LL 80K LL 100K LL 140K ...
Страница 2: ...hances pond oxygen levels by circulating the water The air pumps can be used year round by regulating oxygen levels in the summer and keeping a hole in the icy water during the winter LifeLine areation kits are safe to use in both indoor and outdoor environments Please read this instruction manual carefully to provide optimal performance with your LifeLine Aeration Kit LifeLine Aeration Kit Pg 2 L...
Страница 3: ...FM 5 3 CFM 2 500 Gal 5 000 Gal 8 000 Gal 10 000 Gal 12 000 Gal 15 000 Gal 1 3 1 5 2 6 2 8 2 10 2 10 LL 20 LL 45 LL 65 LL 80 LL 100 LL 140 Model Output Watts Max Pond Max Depth Optimal Depth Pump Specs Air Pumps Pg 3 LifeLine Aeration Kit LL 20 LL 45 LL 65 LL 80 LL 100 LL 140 ...
Страница 4: ... used in water before connecting your LifeLine Air Pump Disconnect the power supply to pump before performing any maintenance procedures Do not operate pump with defective membrane membranes Do not place air pump in water Pump surfaces become very hot during operation allow surfaces to cool before handling Do not place air pump in water The safety of you and others is extremely important Failure t...
Страница 5: ...your pump before using it again Carefully examine the appliance after installation if the supply cord is damaged it must be replaced by a qualified technician in order to avoid hazard Do not carry pump by the power supply cord Disconnect the plug when not in use and before performing maintenance The unit is to be supplied through a residual current device RCD having a rated residual operating curr...
Страница 6: ...Fitting F Manifold G Diffuser Disc B B C 1 C 1 C 2 C 2 C 3 C C A A D D D D 3 D 2 D 1 F 1 G G G F 2 E Note Pliers will be needed for cutting tubing and tightening clamps tools not included Use letter chart below as a guide to connect your LifeLine Air Pump For LL 45 and LL 65 kits begin by cutting 3 3 pieces of tubing Connect as shown LL 20 LL 45 and LL 65 ...
Страница 7: ...Pg 7 LifeLine Aeration Kit LL 100 and LL 140 LL 80 B C 1 C 2 A D D D G G G G F D D B C 1 C 2 A D D D G G G G F D D Connect as shown ...
Страница 8: ...ifeLine Air Pump Note Never install or operate the pump in the vicinity of highly flammable or explosive materials Interval operation When the pump is powered off for several hours in intervals condensation can form from the inside of the unit Store pump in a dry closed room at room temperature to help prevent condensation from happening Place the diffuser discs in different locations under water ...
Страница 9: ...mp after creating an air divider Ensure all tubing is tightly secured when installing your LifeLine Air Pump System Note Avoid Sharp bends when laying out your weighted tubing with diffuser discs attached Discs will work effectively down to 10 feet Old or dirty diffuser discs will reduce aeration capacity Make sure to follow maintenance procedures periodically to prevent build up from pump s airwa...
Страница 10: ...ures Otherwise store unit indoors in a dry room room temperature Manifold Valves Manifold valves allow you to provide air to multiple diffuser discs in different locations around the pond with a single air pump These valves come in a barb width They allow you to turn the air on and off plus they allow you to control the air pressure to each diffuser disc When diffusers are different distances away...
Страница 11: ...e the diagram depressor 7 in diagram below electrostatic membrane 6 in diagram below and diaphragm 5 in diagram below 4 Replace the old diaphragm with a new diaphragm Please note that when fixing make sure the diaphragm fits correctly into the slot of the air chamber 5 Reassemble the pump in the reverse order Visit www anjonmfg com for a step by step guide on how to replace the diaphragm ...
Страница 12: ...atch Remove diaphragm socket Insert new diaphragm s Reassemble the unit in the reverse order see figure 3 below LL 80 LL 100 and LL 140 Instructions Please note a temperature above 104 F can cause the diaphragm in your pump to dry and crack Never operate the unit with defective diaphragms Always replace the complete pair even if one diaphragm is defective Failure to follow these instructions can r...
Страница 13: ...to unplug the pump first before cleaning and maintenance 2 Remove the filter sponge from the air inlet Remove any dust or foreign matter from the air inlet the filter cover and the filter sponge mounting surface If the sponge is heavily soiled you can use a neutral detergent to wash the old sponge down Remember to rinse it well with water completely and dry it in the sun before reinstalling Pg 13 ...
Страница 14: ...ating valves The diffuser discs are dirty Clean the diffuser discs The air filter is dirty Replace air filter Diaphragm defective Replace diaphragm Pump is unusually loud Valve unit or diaphragm defective Replace valve unit or diaphragm Pg 14 LifeLine Aeration Kit 2 1 3 4 5 Note We recommend cleaning diffuser discs a few times throughout the year No bubbles coming out of diffuser disc discs 1 Tubi...
Страница 15: ...t equal to that of the product being replaced No requests for service under this warranty will be accepted if received more than 30 days after the term of the warranty Correction of defects in the manner and for the duration of the warranty described in this warranty shall constitute complete fulfillment of all liabilities and responsibilities of ANJON to the user with respect to the product and s...
Страница 16: ...1000 Liberty Industrial Drive O Fallon MO 63366 1 800 553 5605 www anjonmfg com ...