CNC Motion Setup/Testing Utility
P/N 70000634A
All rights reserved. Subject to change without notice.
23-December-05
23
Reset Amplifier
This feature is only for systems equipped with an ANILAM AC Amplifier
(P/N 33001279) and with the Servo Amplifier Communications Cable, P/N
33001389, connected.
This resets the AC Amplifier.
BackUp Amp Settings
This feature is only for systems equipped with an ANILAM AC Amplifier
(P/N 33001279) and with the Servo Amplifier Communications Cable, P/N
33001389, connected. Refer to “Restore from Backup.”
To backup amplifier parameters:
1. Select an axis (i.e., X, Z).
2. Press
Misc
(
F9
) to display the pop-up menu.
3. Highlight
BackUp Amp Settings
and press
ENTER
. A message is
displayed indicating the amplifier backup file is created.
This reads all parameters from the amplifier and creates a backup file
named DIGAMP-*.BK, where ‘*’ is the selected axis name (i.e., X, Z).
This file is stored on the hard disk drive.
NOTE:
The backup file is compatible with the file generated by
MotionMaestro. When functions pertaining to ANILAM AC Drive
are selected, the user needs to have a RS-232 communication
cable connected between the amplifier and the CNC.
Restore from BackUp
This feature is only for systems equipped with an ANILAM AC Amplifier
(P/N 33001279) and with the Servo Amplifier Communications Cable, P/N
33001389, connected.
To restore amplifier parameters from backup:
1. Select an axis (i.e., X, Z).
2. Press
Misc
(
F9
) to display the pop-up menu.
3. Highlight
Restore from BackUp
and press
ENTER
. A message is
displayed indicating the amplifier backup file is restored created.
This sends the parameters in the backup file to the amplifier.
Exiting the MST Screen (F10)
Press
Exit
(
F10
) to exit the MST Screen and return to the Software
Options screen in the Setup Utility.
Содержание 4200T CNC