CNC Motion Setup/Testing Utility
P/N 70000634A
All rights reserved. Subject to change without notice.
23-December-05
22
Save Amp Settings
This feature is only for systems equipped with an ANILAM AC Amplifier
(P/N 33001279) and with the Servo Amplifier Communications Cable, P/N
33001389, connected. Refer to “
Motion Setup and Testing (MST)
Saves all modified amplifier parameters to non-volatile memory. This
must be done after performing a signal gain test and/or a balance test.
Balance Test
– When Balance test [
Balance
(
F6
)] is selected and if the
Communication link between the CNC and ANILAM AC Drive is
enabled/open, the Parameter IAO (Analog 1 Input Offset) will be
displayed and you will be able to modify it by using the up/down
arrow
keys. Use right/left
arrow
to change the increment amount (which is set
on Setup Utility). Save the final value by selecting
Save Amp Settings
[
MISC
(
F9
)].
Signal Gain Test
– When Signal Gain test [
SigGain
(
F7
)] is selected and
if the Communication link between the CNC and ANILAM AC Drive is
enabled/open, the Parameter IAS (100% PWM RPM Value) will be
displayed and you will be able to modify it using the up/down
arrow
keys.
Also, the Compensation (equivalent to Comp Pot) parameter GVC
(Velocity Loop Master Gain) will also be displayed; you will be able to
modify it by using right/left
arrow
keys. Every time you press the
arrow
keys, the value will be incremented by the amount entered in the Setup
Utility. Save the final value(s) by selecting
Save Amp Settings
[
MISC
(
F9
)].
These two tests should cover the equivalent of Signal, Balance & Comp
Pots on the analog drives.
Amplifier Test Link
This feature is only for systems equipped with an ANILAM AC Amplifier
(P/N 33001279) and with the Servo Amplifier Communications Cable, P/N
33001389, connected.
This enables/disables
the communications monitor. The communications
monitor has two modes of operation: Monitor and Command. Using an
external keyboard, use hot key (
CTRL
+
F7
) to switch between the two
modes.
Monitor:
(Default) During this mode, you can monitor all
communication between the Amplifier and the Control.
Command:
During this mode, it not only monitors all communications;
but also, allows you to send direct commands to the
Amplifier.
Содержание 4200T CNC
Страница 1: ...www anilam com ...