29
STEP 1: IRIS SUB-ASSEMBLY
THE BELOW PROCEDURE APPLIES FOR ALL OPTIMO PRIME SERIES
0 - Put the iris ring at the maximum opened T-stop position.
1 - Mount the iris sub-assembly onto the internal part of the IOP element spanner 66067121AA. First, rotate the iris-subassembly anti-clockwise
so it falls in the correct thread position.
2 - Tighten the iris sub-assembly up to the end-stop. Do not apply more torque after you reached the end-stop.
3 - Align the pin positioning hole of the iris sub-assembly with the internal iris positioning pin. Align the iris pin with the internal iris hole.
4 - Put the iris-sub-assembly back in the lens by sliding straightly the internal part of the IOP element spanner.
5 - Untighten and pull out the internal part of the IOP element spanner.
6 - Keeping the lens vertically, check that the iris is functioning correctly by rotating the iris gear. The iris blades should close and open correctly
and the iris sub-assembly should not move.
2
3
4
5
Содержание IOP
Страница 1: ...User manual IOP IOP user manual V1 0...