15
ADDITIONAL TOOLS
In addition to your IOP tooling set you will need a Phillips screwdriver to remove the front ring, front engraved ring and front optical group holding
screws. As an example we are using in factory the Phillips screwdriver VESSEL 9900 P.00-75. You will need also a pair of tweezers to pick
accurately the screws you are removing to prevent from any damage or screw drop.
CAUTION:
as you are opening the product, this operation must be done with cautious in a clean and dry environment to prevent dust or particles
pollution inside the lens. We advise you to wear adapted gloves to leave no traces on the optical elements and mechanics.
CAUTION:
when you are removing the screws holding the front ring or the front group, be cautious to secure the screws removing using a pair of
tweezers to prevent from any drop or damage. Remove with cautious the retainers using the hands and a pair of tweezers to prevent from any
drop or damage.
CAUTION:
before removing a ring, a retainer or an element, do always check the thread or element cleanliness. If necessary, clean the thread
or mechanical element blowing dry air or using a soft brush. For optical elements, blow dry air and do always use a soft optical cloth and an
isopropyl alcohol liquid starting with the center and cleaning by turning outwards.
CAUTION:
when putting back the focus or front group, we recommend blowing dry air onto the two side lenses of the optical sub-assembly. Do
not do this above the opened Optimo Prime lens to prevent from dust pollution. In case you need to clean a lens, do always use a soft optical
cloth and an isopropyl alcohol liquid starting with the center and cleaning by turning outwards.
CAUTION:
when putting back a retainer or a threaded front ring, check the thread cleanliness and clean the thread or mechanical element blowing
dry air and using a soft brush. Do not do this above the opened Optimo Prime lens to prevent from dust pollution. To be sure the thread fits
perfectly, rotate the part you are putting back anti-clockwise with the hands or a pair of tweezers so it falls in the correct thread position before
tightening it. Do not apply any strong torque and check if the element is rotating easily before tightening clockwise. You may put in the thread a
very small amount of mechanical grease all around if you note some mechanical friction.
5
– IOP element swap
Содержание IOP