Model

Nozzle

Air Cap

Air pressure at gun inlet

Fluid 

Air

Pattern

Weight

orifice

Set

bar (PSI)

output

comsumption

width

mm(in)

Mark

Atomizing air

Fan air

g/m 

Nl/min

mm(in)

g (lbs)

WRA-101S9/S9N Pressure feed

WRA-101-S9-04P

0.4 (0.016)

35 (1.4)

290 (0.64)

WRA-101-S9-06P

0.6 (0.024)

70 (2.8)

310 (0.68)

WRA-101-S9-10P

1.0 (0.039)

100 (3.9)

310 (0.68)

WRA-101-S9N-04P 0.4 (0.016)

35 (1.4)

290 (0.64)

WRA-101-S9N-06P 0.6 (0.024)

70 (2.8)

310 (0.68)

WRA-101-S9N-10P 1.0 (0.039)

100 (3.9)

310 (0.68)

IMPORTANT

This automatic spray gun should be operated only by an adequately trained operator for safe use and maintenance of the equip-
ment. Any misuse or handling other than those indicated in this Instruction Manual is not covered by guarantee.  

ANEST IWATA

disclaims all responsibility for any accident or damage caused by failure observing the operational and safety pro-

cedures as from this manual. In the interest of user friendliness, this manual contains information in a brief and concise form.
For any additional information you may require regarding the automatic spray gun operations, or if any missing parts or any dam-
age during transportation is found, or details of training courses, please contact your nearest 

ANEST IWATA Company 

(see last

cover page).

Manufactured by:  

ANEST IWATA Corporation

3176,Shinyoshida-cho, Kohoku-ku, Yokohama, 223-8501 Japan

Instruction Manual

This 

ANEST IWATA

spray guns kit complies to ATEX regulations 94/9/EC, 

Protection level: II 2 G X Suitable for using Zones 1 and 2.

X marking: Any static electricity discharge from the spray gun is to be diverted to the ground via the conductive air hose as stipulated. 

Before use, adjustment or maintenance, it is important to read this instruction manual very care
fully. This manual must be stored in a safe place for any future reference that may be necessary. 

GB

MJ-T049-01EREV

.0

IMPORTANT SPECIFICATIONS

Max. Operating air pressure:

6.8 bar (98 PSI)

Max. Temperature:

Noise Level (LAeqT):

78.7 dB (A)*

Atmosphere

5 ~ 40 °C

Air connection:

3-Rc 1/4”

Air and fluid

5 ~ 43 °C

Fluid connection:

2-Rc 1/4”

TECHNICAL SPECIFICATIONS

Be sure to observe warnings and cautions in this instruction manual.

If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.

Be sure to observe following        marked items which are especially important.

WARNING

Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or pro-

perty damage.

IMPORTANT

Indicates notes which we ask you to observe.  The safety precautions in this instruction manual are the mini-

mum necessary conditions.  Follow national and local regulations regarding fire prevention, electricity and 

safety as well as your own company regulations.

E2

1.1 (16)

1.5 (21)

20

140 (4.9)

ANEST IWATA Italia S.r.l.

46, Corso Vigevano 10155, Torino (Italy

)

Tel. d39 011 - 24 80 868 - Fax: +39 011 - 85 19 44
[email protected]

www.anest-iwata.it

ANEST IWATA Iberica

Calle de Les Teixidores, 3-5
08918 - Badalona (Barcelona)
Tel.:+34 933 20 59 93 - Fax.:+34 933 20 59 65
[email protected]

www.anest-iwata.es

ANEST IWATA Europe S.r.l.

NIEDERLASSUNG DEUTSCHLAND
Dorfäckerstr. 23/1, 74248 Ellhofen
Telefon: +49 (0) 7134- 917368 - Fax: +49 (0) 7134 - 917378
Handy: +49 (0) 172 - 62 74 542
[email protected]

www.anest-iwata.de

ANEST IWATA Europe S.r.l.

46, Corso Vigevano 10155, Torino Italy
Direct Tel. +39 011 - 22 74 402
Fax +39 011 - 22 74 406
[email protected]

www.anest-iwataeu.com

ANEST IWATA Scandinavia 

Ögärdesvägen 6C, 433 30 PARTILLE - Sweden 
Tel. +46 (0)31 - 340 28 60 - Fax +46 (0)31 - 340 28 69
[email protected]

www.anest-iwata.se

ANEST IWATA France 

25 rue de Madrid - 38070 St Quentin Fallavier - France
Tél. +33 (0)4 - 74 94 59 69 - Fax +33 (0)4 - 74 94 34 39
[email protected]

www.anest-iwata.fr

ANEST IWATA  U.K.

Unit 10 Little End Road - Eaton Socon
St. Neots - CAMBRIDGESHIRE
PE19 8JH 
Tel.: +44 (0) 1480 405419  Fax: +44 (0) 1480 217610
[email protected]

www.anest-iwata.co.uk

European Sales Branches:

WRA 101-S9/S9N AUTOMATIC SPRAY GUN

* Measuring point: 1m backwards from gun, 1,6 m height  

Содержание WRA 101-S9

Страница 1: ...re 5 40 C Air connection 3 Rc 1 4 Air and fluid 5 43 C Fluid connection 2 Rc 1 4 TECHNICAL SPECIFICATIONS Be sure to observe warnings and cautions in this instruction manual If not it can cause paint ejection and serious bodily injury by drawing organic solvent Be sure to observe following marked items which are especially important WARNING Indicates a potentially hazardous situation which if not ...

Страница 2: ...ray gun If done it can cause insufficient performance and failure 2 Enter working areas of other equipment robots reciprocators etc after machines are turned off If not contact with them can cause injury 3 Never spray foods or chemicals through this gun If done it can cause accident by corrosion of fluid passages or adversely affect health by mixed foreign matter 4 If something goes wrong immediat...

Страница 3: ...yes Use two way or three way solenoid valve of more than ø 4 inner dia cross sectional area and air hose of over ø 6 inner dia and less than 10m length If not small dia of solenoid valve and longer air hose between three way solenoid valve and gun can cause delay in operation Firmly fix hose to spray gun If not disconnection of hose and drop of container can cause bodily injury SPARE PARTS LIST Mo...

Страница 4: ...or protection of the human body Be careful not to damage the tip of the fluid nozzle or not put your hand on it Only an experienced person who is fully conversant with the equipment can do maintenance and inspection CAUTION Never use commercial or other parts instead of ANEST IWATA original spare parts Never immerse the whole gun into liquid such as thinner Never soak air cap set in solvent for ex...

Отзывы: