Model
Nozzle
Air Cap
Air pressure at gun inlet
Fluid
Air
Pattern
Weight
orifice
Set
bar (PSI)
output
comsumption
width
mm(in)
Mark
Atomizing air
Fan air
g/m
Nl/min
mm(in)
g (lbs)
WRA-101S9/S9N Pressure feed
WRA-101-S9-04P
0.4 (0.016)
35 (1.4)
290 (0.64)
WRA-101-S9-06P
0.6 (0.024)
70 (2.8)
310 (0.68)
WRA-101-S9-10P
1.0 (0.039)
100 (3.9)
310 (0.68)
WRA-101-S9N-04P 0.4 (0.016)
35 (1.4)
290 (0.64)
WRA-101-S9N-06P 0.6 (0.024)
70 (2.8)
310 (0.68)
WRA-101-S9N-10P 1.0 (0.039)
100 (3.9)
310 (0.68)
IMPORTANT
This automatic spray gun should be operated only by an adequately trained operator for safe use and maintenance of the equip-
ment. Any misuse or handling other than those indicated in this Instruction Manual is not covered by guarantee.
ANEST IWATA
disclaims all responsibility for any accident or damage caused by failure observing the operational and safety pro-
cedures as from this manual. In the interest of user friendliness, this manual contains information in a brief and concise form.
For any additional information you may require regarding the automatic spray gun operations, or if any missing parts or any dam-
age during transportation is found, or details of training courses, please contact your nearest
ANEST IWATA Company
(see last
cover page).
Manufactured by:
ANEST IWATA Corporation
3176,Shinyoshida-cho, Kohoku-ku, Yokohama, 223-8501 Japan
Instruction Manual
This
ANEST IWATA
spray guns kit complies to ATEX regulations 94/9/EC,
Protection level: II 2 G X Suitable for using Zones 1 and 2.
X marking: Any static electricity discharge from the spray gun is to be diverted to the ground via the conductive air hose as stipulated.
Before use, adjustment or maintenance, it is important to read this instruction manual very care
fully. This manual must be stored in a safe place for any future reference that may be necessary.
GB
MJ-T049-01EREV
.0
IMPORTANT SPECIFICATIONS
Max. Operating air pressure:
6.8 bar (98 PSI)
Max. Temperature:
Noise Level (LAeqT):
78.7 dB (A)*
Atmosphere
5 ~ 40 °C
Air connection:
3-Rc 1/4”
Air and fluid
5 ~ 43 °C
Fluid connection:
2-Rc 1/4”
TECHNICAL SPECIFICATIONS
Be sure to observe warnings and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
Be sure to observe following marked items which are especially important.
WARNING
Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or pro-
perty damage.
IMPORTANT
Indicates notes which we ask you to observe. The safety precautions in this instruction manual are the mini-
mum necessary conditions. Follow national and local regulations regarding fire prevention, electricity and
safety as well as your own company regulations.
E2
1.1 (16)
1.5 (21)
20
140 (4.9)
ANEST IWATA Italia S.r.l.
46, Corso Vigevano 10155, Torino (Italy
)
Tel. d39 011 - 24 80 868 - Fax: +39 011 - 85 19 44
[email protected]
www.anest-iwata.it
ANEST IWATA Iberica
Calle de Les Teixidores, 3-5
08918 - Badalona (Barcelona)
Tel.:+34 933 20 59 93 - Fax.:+34 933 20 59 65
[email protected]
www.anest-iwata.es
ANEST IWATA Europe S.r.l.
NIEDERLASSUNG DEUTSCHLAND
Dorfäckerstr. 23/1, 74248 Ellhofen
Telefon: +49 (0) 7134- 917368 - Fax: +49 (0) 7134 - 917378
Handy: +49 (0) 172 - 62 74 542
[email protected]
www.anest-iwata.de
ANEST IWATA Europe S.r.l.
46, Corso Vigevano 10155, Torino Italy
Direct Tel. +39 011 - 22 74 402
Fax +39 011 - 22 74 406
[email protected]
www.anest-iwataeu.com
ANEST IWATA Scandinavia
Ögärdesvägen 6C, 433 30 PARTILLE - Sweden
Tel. +46 (0)31 - 340 28 60 - Fax +46 (0)31 - 340 28 69
[email protected]
www.anest-iwata.se
ANEST IWATA France
25 rue de Madrid - 38070 St Quentin Fallavier - France
Tél. +33 (0)4 - 74 94 59 69 - Fax +33 (0)4 - 74 94 34 39
[email protected]
www.anest-iwata.fr
ANEST IWATA U.K.
Unit 10 Little End Road - Eaton Socon
St. Neots - CAMBRIDGESHIRE
PE19 8JH
Tel.: +44 (0) 1480 405419 Fax: +44 (0) 1480 217610
[email protected]
www.anest-iwata.co.uk
European Sales Branches:
WRA 101-S9/S9N AUTOMATIC SPRAY GUN
* Measuring point: 1m backwards from gun, 1,6 m height