1
−
INSTRUCTION MANUAL
Spray Gun
Be sure to observe warning s and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
Be sure to observe following marked items which are especially important
.
Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of
life.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury
or property damage.
Indicates notes which we ask you to observe. The safety precautions in this instruction manual are
the minimum necessary conditions. Follow national and local regulations regarding fire prevention,
electricity and safety as well as your own company regulations.
Abbreviate Marking on the Spray Gun:
II 2 G Ex h X
This ANEST IWATA spray gun
complies with 2014/34/EU Directive
relating to equipment and protective
systems intended for use in explosive
potentially atmospheres.
II
2
G
Ex h
IIB
T6
Gb
X
T
Amb
+5°C +40°C
Complies
with
European
Directive
Specific
Marking for
Explosion
Protective
Group II
(Surface)
Category
(Zone 1&2)
Type of
Atmosphere
(GAS)
Ignition
Protection
(not applied)
Explosion
Group
(Ethylene)
Temperature
Class
( 85°C)
Explosion
Protection
level
(EPL)
Additional
conditions:
Any static
Electricity should
be discharged
and needs to be
diverted to the
ground via a
conductive air
hose not
included.
Ambient
Temperature
Important specifications
Max. Pressure
0.70MPa / 7.0bar / 100psi
Noise level
80dB(A)
Spray condition
Recommended
Measuring point
1m backwards from spray gun, 1.6m height
Max. temperature
Atmosphere: 5°C ~40°C (41°F~104°F)
Air and Fluid: 5°C ~43°C (41°F~109°F)
*1. Atomizing air pressure means air pressure at spray gun inlet when trigger is pulled and air flows.
Important
Never connect pressure feeding paint except pressure feed type spray gun.
Main specifications
Model
Type of feed
Nozzle orifice
mm (in)
Air cap assy
Mark
Recommended condition
Air consumption
l/min (cfm)
Pattern width
mm (in)
Air & fluid
connection
Mass
g (lbs.)
*1 Atomizing air
pressure
MPa (bar / PSI)
Fluid output
ml/min
WIDER2-12G2P
Pressure
1.2 (0.047)
G2P
0.29
(3.0 / 43)
500
500 (17.7)
400 (15.7)
Air
G1/4
(NPS1/4)
Fluid
G3/8
(NPS3/8)
375
(0.83)
WIDER2-15K1S
Suction
1.5 (0.059)
K1
240
200 ( 7.1)
210 ( 8.3)
-15K2S
K2
330 (11.7)
290 (11.4)
-18K2S
1.8 (0.071)
290
340 (13.4)
-20R1S
2.0 (0.079)
R1
350
260 ( 9.2)
260 (10.2)
-20R2S
R2
360 (12.7)
290 (11.4)
-25W1S
2.5 (0.098)
W1
440
280 (11.0)
WIDER2-15K1G
Gravity
1.5 (0.059)
K1
270
200 ( 7.1)
220 ( 8.7)
-15K2G
K2
330 (11.7)
320 (12.6)
-18K2G
1.8 (0.071)
290
340 (13.4)
-20R1G
2.0 (0.079)
R1
410
260 ( 9.2)
280 (11.0)
-20R2G
R2
360 (12.7)
320 (12.6)
-25W1G
2.5 (0.098)
W1
510
310 (12.2)
WIDER2-2-08G2P
Pressure
0.8 (0.031)
2-G2
0.16
(1.6 / 23)
200
340 (12.0)
360 (14.1)
-10G2P
1.0 (0.039)
250
360 (14.1)
-12G2P
1.2 (0.047)
300
380 (14.9)
This manual contains IMPORTANT
WARNINGS and INSTRUCTIONS.
Equipment in this manual is exclusively for
painting purposes.
Do not use for other purposes.
The operator shall be fully conversant with
the requirements stated in this instruction
manual including important warnings,
cautions and operation and correct handling.
Read and understand the instruction
manual, before use and retain for reference.
Fluid nozzle – Fluid needle assy combination
Fluid nozzle
Fluid needle
assy
Orifice mm (in)
Mark
Mark
1.2 (0.047)
/ W2 / 12
12H WIDER2
1.5 (0.059)
/ W2 / 15
15 WIDER2
1.8 (0.071)
/ W2 / 18
18 WIDER2
2.0 (0.079)
/ W2 / 20
20 WIDER2
2.5(0.098)
/ W2 / 25
25 WIDER2
0.8 (0.031)
/ W2-2/ 08
12 WIDER2
1.0 (0.039)
/ W2-2/ 10
1.2 (0.047)
/ W2-2/ 12
Содержание WIDER2-12G2P