Anern N POWERWALL 2.0 Скачать руководство пользователя страница 1

N POWERWALL 2.0 LFP Battery Series 

User Manual 

 

 

 

 

Web: marketing-anern.com | Email: [email protected] | Whatsapp: +86 13058030989

Содержание N POWERWALL 2.0

Страница 1: ...N POWERWALL 2 0 LFP Battery Series User Manual Web marketing anern com Email marketing anern com Whatsapp 86 13058030989...

Страница 2: ...Product Information 5 2 1 Battery Overview 5 2 2 Appearance 6 2 3 Dimensions 6 2 4 Capacity Options 7 2 5 Display 8 2 6 Operation 8 2 7 Multiple Batteries Parallel Connection 10 3 Specifications 11 3...

Страница 3: ...ized information to avoid personal injury and property damage Relative safety symbols have been listed below DANGER indicates a hazardous situation which if not avoided will result in serious injury a...

Страница 4: ...ry terminals Do not stand on lean on or sit on the battery 1 3 Electrical Safety Symbols on battery There are some electrical symbols on battery relate to electrical safety Please make sure you have f...

Страница 5: ...operation Recharge battery in every six months Recharge battery within 10 days after battery is fully discharged Please engage greater than or equal to two batteries when maximum charge current is mor...

Страница 6: ...mable or explosive gas or smoke Do not perform any operation on the equipment in such environments The operation and service life of the battery depends on the operating temperature Operate the batter...

Страница 7: ...the requirements of the inverter controller It is mainly for home energy storage system Features LiFePO4 prismatic cell 6000 cycles 0 5C conditions Maximum 1C charge and discharge capability Wall mou...

Страница 8: ...e terminal Negative terminal Battery parallel communication port Inverter communication port Dial the code switch Operating area The power switch 2 3 Dimensions 2 2 Appearance Web marketing anern com...

Страница 9: ...d energy kWh The maximum power kW is limited by main cables from master battery to inverter The maximum 16 battery packs can be parallelly communicated For example ONE PACK is 4 8kWh 4 8kWh 9 6kWh 19...

Страница 10: ...ion Power Switch ON OFF To power on the whole battery system no power output Power Connector There are two sets of power connectors in the operation area as shown in the figure the one on the left is...

Страница 11: ...load and the baud rate is 2400bps RS232 upload communication interface It can communicate with the host computer through the RS232 communication interface INVCOM pin interface definition BATCOM The BM...

Страница 12: ...dress switch settings 2 7 Multiple Batteries Parallel Connection Please set dip address switches as above Please see communication ports link connection below Please see power parallel connection belo...

Страница 13: ...l 2 8V 3 60V Working Temperature Charge 0 55 Discharge 20 60 Storage Temperature 10 35 Nominal Capacity kWh 2 56kWh 5 12kWh Max Charge Current A 70A 100A Max Discharge Current A 75A 100A Cycle Life 60...

Страница 14: ...2 8V 3 6V Working Temperature Charge 0 55 Discharge 20 60 Storage Temperature 10 35 Nominal Capacity kWh 4 8kWh Max Charge Current A 75A Max Discharge Current A 75A Cycle Life 6000 25 0 5C 85 DOD SOC...

Отзывы: