5.2 - gSM mode
The GSM mode should be activated when
S-BoX
is connected to a GSM gateway.
To activate this mode:
In programming mode:
Enter #405# To come back to normal mode (PSTN)
In programming mode:
Enter #406#
5.2.1 - Managing Battery default on gSM Pg1 gateway
PG1 gateway constantly supervises its battery. In case of default, PG1 gateway sends the
info to the
S-BoX
module. Accordingly, when GSM mode is activated, the master
S-BoX
module
controls the battery default of the gateway. After detection of this default, ANEP
BOX
generates a data call “GSM battery default start. After recharging or replacement of the
battery, the Gateway sends information to
S-BoX
module, that generates a call “GSM Bat-
tery default end”.
5.3 - Programming numbers
Note : 101 = Principal emergency call number
102 = Secondary emergency call number
103 = Third emergency call number
5.3.1 - Programmaming memories 101/102/103
After entering the programming mode access code : (example for the principle call number)
Enter the sequence «
#
1 0 1
»
Enter the telephone number followed by the key « # »
5.3.2 - Programming a pause
When installed behind a PABX, a prefix and a pause may be necessary before getting a
external line
To program a PAUSE (
2
seconds), press the key «
*
»
Example :
Pause
after a prefix
0
(for memory 102)
# 102 0
*
0 1 4 5 6 9 2 8 0 0
press the «
#
» key to validate the number