Problem
Possible cause
Solution
The DG500 scale
system or SMART
Box (option) is not
turning on.
The
three- prong
plug
between the tractor and
machine
has
been
unplugged.
Plug it back in.
The tractor’s power supply is
defective.
1. Check the tractor's fuse.
2. Check the tractor's electrical system.
There is an electrical issue
with the weight indicator.
Contact your dealer.
The power cable fuse blew.
Replace the fuse.
The SMART Box
fuse blows when
the SMART Box is
powered on.
The SMART Box power cord
is connected to the tractor
with reversed polarity.
Connect the positive terminals together
and the negative terminals together.