SPECIFICATIONS
Model A100F
Unit Weight
64 lbs�
Shipping Weight
82 lbs�
Capacity
AHAM DH-1-2008 80°F, 60% RH Conditions
100 pints per day @ 280 CFM
Efficiency
2�6 L/kW-hr (5�7 pints/kW-hr) @ 80°F, 60% RH
Power
115 VAC, Single Phase, 60Hz
6�9A operating current
Dehumidifier Inlet Air Conditions
Dehumidification:
50°F – 104°F, 40°F dew point minimum
Ventilation:
40°F – 140°F, 0% RH – 99% RH (non-condensing)
Filter
MERV 11
Airflow
280 CFM
SAFETY INSTRUCTIONS
WARNING
1.
120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing. Leave power
disconnected until installation/service is completed.
2.
Dropping may cause personal injury or equipment damage. Handle with care and follow installation instructions.
CAUTION
1.
Read all instructions before beginning installation.
2.
Improper installation may cause property damage or injury. Read instructions before installation, service or maintenance.
3.
Do not use in pool applications. Pool chemicals can damage the dehumidifier.
4.
Do not use solvents or cleaners on or near the circuit board. Chemicals can damage circuit board components.
5.
Wait 24 hours before running the unit if it was not shipped or stored in the upright position
6.
Do not use dehumidification to prevent window condensation in the winter. To address window condensation, use ventilation to lower
indoor humidity in the winter.
7.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
8.
Children should be supervised to ensure that they do not play with the appliance.
9.
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.