User manual
Guangzhou Andea Electronics Technology Co., Ltd. 8/15
http://www.gzandea.com
4.2.4.
Inventory Parameters
Figure 11
Configuration interface for inventory parameters
⚫
Basic options
1)
Disable anti-collision: whether to turn off anti-collision function.
2) Beep when discovery tags: set whether the buzzer buzzes when the tag is
detected.
3) Only read new tags: each tag is only read once, when it does not leave the
antenna sensing area.
4)
Stop Trigger
Try N times when no tags: set the number of attempts if no new tags are found.
Max Timeout: set the time of stopping trigger due to timeout.
⚫
ISO15693
1)
AFI: 00-FF.Note: 00 means not to enable.
2)Slot Number: 1 Slot, 16 Slot.
⚫
ISO18000p3m3
1)
Start Q:0-15.
2) Session: session 0, session 2.
3)
Use dynamic Q:whether to enable dynamic Q value.
4) Min dynamic Q: set the minimum dynamic Q value.
5) Max dynamic Q: set the maximum dynamic Q value.