4.2.4.

 

Inventory Parameters 

 

Figure 11

 

Configuration interface for inventory parameters 

 

Basic options 

1)

 

Disable anti-collision: whether to turn off anti-collision function. 

2) Beep when discovery tags: set whether the buzzer buzzes when the tag is 

detected. 

3) Only read new tags: each tag is only read once, when it does not leave the 

antenna sensing area. 

4)

 

Stop Trigger 

Try N times when no tags: set the number of attempts if no new tags are found. 

Max Timeout: set the time of stopping trigger due to timeout. 

 

ISO15693   

1)

 

AFI: 00-FF.Note: 00 means not to enable. 

2)Slot Number: 1 Slot, 16 Slot. 

 

ISO18000p3m3   

1)

 

Start Q:0-15. 

2) Session: session 0, session 2. 

3)

 

Use dynamic Q:whether to enable dynamic Q value. 

4) Min dynamic Q: set the minimum dynamic Q value. 

5) Max dynamic Q: set the maximum dynamic Q value. 

Содержание RL865

Страница 1: ...please read this manual carefully and properly keep it for future reference As our products continue improving they may be changed without advanced notice The copyright of this manual belongs to our c...

Страница 2: ...Version V1 0...

Страница 3: ...Light 3 4 Device Connection Instructions 3 4 1 Device Connection Instructions 3 4 2 Configuration Description Of Parameters 5 4 2 1 Communication Interface 5 4 2 2 Buzzer Default Parameters 6 4 2 3 RF...

Страница 4: ...f various protocols at the same time This product is widely used in desktop card issuance access control electronic bills Libraries and other fields 1 2 Product Features Operating frequency 13 56MHz S...

Страница 5: ...6Mhz Support Standard ISO 15693 ISO 14443A ISO 18000 3M3 Communication Interface USB Voltage 150mA 5V Maximum Recognition Distance ISO 15693 11cm ISO 14443A 7cm Standard Sizes 54 34 5mm Maximum Operat...

Страница 6: ...light After the device is powered on and the performance is normal the light flashes red slow flashing and the light is not bright when it is abnormal when the device is performing inventory work the...

Страница 7: ...below Figure 5 R Tool connection interface Since the device is connected via USB you need to select USB in the Communication Interface item under Search Parameters The search steps are as follows Sel...

Страница 8: ...r the device configuration and test interface 4 2 Configuration Description Of Parameters 4 2 1 Communication Interface Figure 8 Configuration interface for communication interface Bus Address between...

Страница 9: ...Frequency value range from 0 to 255 only applicable for the Flash type Active time the frequency of buzzer only applicable for the Flash type Note The device V00 02 and above including V00 02 version...

Страница 10: ...O14443A Enable to count tags of ISO14443A air protocol 3 ISO18000p3m3 Enable to count tags of ISO18000p3m3 air protocol 4 ISO14443B Enable to count tags of ISO14443B air protocol ISO15693 1 Data codin...

Страница 11: ...ed 3 Only read new tags each tag is only read once when it does not leave the antenna sensing area 4 Stop Trigger Try N times when no tags set the number of attempts if no new tags are found Max Timeo...

Страница 12: ...ventory can be automatically completed even if the host software does not send commands scan setting in the scan mode should be configured in advance Scan Mode Configuration 1 Filtered time of duplica...

Страница 13: ...bytes UID length 0 8 0 for unlimited length output of a complete UID 4 Parameter of reading block with ISO15693 Byte offset the offset of the first byte to be read Byte count the number of bytes to b...

Страница 14: ...interface of the software Step 2 Select the Inventory in the drop down list above the Start button Step 3 Click the Start button to carry out the inventory testing 4 3 2 Single Tag Operation Testing I...

Страница 15: ...r multiple tags in UID drop down box select the tags required to be operated and then click the Connect button The green area represents the set operating area Figure 15 Single tag reading and writing...

Страница 16: ...d 13 15 http www gzandea com 5 Technical Support Download link for development data and testing https www gzandea com download php Call for equipment debugging and technical support Mobile phone 138 0...

Страница 17: ...and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular...

Страница 18: ...the device into which the module is installed must also display a label referring to the module The final end device must be labeled in a visible area with the following Contains FCC ID 2AFI8 RL865 Co...

Отзывы: