AMD5x Passive Infeed Unit and AMD5x Servo Drive - User Guide
ANCA MOTION
D-000129 Rev 09
118
Attribute
Qualification
Physical Characteristics
10.5.6
Degree of Ingress Protection (IP Rating)
IP 20 in accordance with EN60529
5
Mounting position in Operation
Vertical
15kW and 24kW PIU Physical Characteristics
10.5.7
Duct Mount
Wall Mount
Recessed Mount
Device Weight
4.1kg
6.1kg
6.1kg
Height (mm)
362
362
362
Width (mm)
125
125
125
Depth (mm)
191
157
157
Drive Physical Characteristics
10.5.8
Duct Mount
Wall Mount
Recessed Mount
Excluding IO Interface
3A, 6A, 12A
and 20A
35A and
35AH
3A, 6A, 12A
and 20A
35A and
35AH
3A, 6A, 12A
and 20A
35A and
35AH
Device Weight
3.0kg
4.4kg
4.5kg
6.5kg
4.5kg
6.5kg
Height (mm)
362
362
362
362
362
362
Width (mm)
89
125
89
125
89
125
Depth (mm)
191
191
157
157
157
157
Including IO Interface
3A, 6A, 12A
and 20A
35A and
35AH
3A, 6A, 12A
and 20A
35A and
35AH
3A, 6A, 12A
and 20A
35A and
35AH
Device Weight
3.0kg
4.4kg
4.5kg
6.5kg
4.5kg
6.5kg
Height (mm)
362
362
362
362
362
362
Width (mm)
89
125
89
125
89
125
Depth (mm)
6
193
193
159
159
159
159
Capacitor Module Physical Characteristics
10.5.9
Device Weight
3.1kg
3.2kg
3.1kg
Height (mm)
362
362
362
Width (mm)
125
89
125
Depth (mm)
111
157
111
5
The top surface of cabinets/enclosures which are accessible when the equipment is energized shall meet the requirement of
protective type IP3X with regard to vertical access only.
6
Depth of Drive variants with BiSS Interface will be 2mm less than the IO Interface dimensions.