NOVUS AUTOMATION
48/85
•
Publishing Interval:
Allows for selecting the interval, in seconds, at which
LogBox Wi-Fi
will publish data pending in the memory to
NOVUS
Cloud
.
•
Clear CIK:
If selected, it allows you to clear the CIK value, a number provided automatically by
NOVUS Cloud
during the first device
authentication on the platform. If there are connection problems or if you want to re-register the device in a new user account, you can clear the
CIK to restart it on the device. If this process is performed, it is necessary to re-register the device in a
NOVUS Cloud
account.
•
Enable automatic clock synchronization:
If selected, it allows you to enable the automatic clock update feature through
NOVUS Cloud
. See
parameter
Sync if longer than
for more information about this feature.
o
Sync if longer than:
If the automatic clock synchronization feature is enabled, the parameter will determine the maximum time (in
seconds) difference between the
LogBox Wi-Fi
clock and the
NOVUS Cloud
server to update the
LogBox Wi-Fi
clock.
13.1.6.5
SMTP PROTOCOL
NXperience
NXperience Mobile
Android
iOS
Figure 17 –
Configuration Screen: SMTP
•
Enable SMTP:
Allows you to enable or disable e-mail sending features (see
chapter). When the
LogBox Wi-Fi
does not have
an external power source active and is running on batteries, the Wi-Fi interface will remain disabled and therefore will send data through this
protocol as well.
•
Configuration:
Allows you to enter the data required to perform the user authentication on the selected server.
o
Server:
Allows you to select the server of the email to be used.
o
Connection Security:
Allows you to select the security mode of the connection, which may occur in an insecure way or with the TLS
protocol.
o
Server Address:
Allows you enter the address of the email server to be used.
o
Port:
Allows you to enter the connection port to be used by the e-mail server.
o
User:
Allows you to enter the username of the e-mail to be used.
o
Password:
Allows you to enter the password of the user of the e-mail to be used.
o
Message Lifetime:
Allows you to set how long ago the device will evaluate the logs to send an alarm e-mail. This parameter will also
prevent the user from receiving e-mails with alarm messages registered outside the period of interest. You can set a minimum limit of 1
minute or a maximum limit of 200 hours.
•
E-mail:
Allows you to enter the sender's e-mail, a title and the message that will be sent to the downloaded data about the configured alarm.
o
Sender:
Allows you to enter the sender's e-mail address for the e-mail to be sent.
o
Subject:
Allows you to enter the subject of the e-mail to be sent.
o
Message Body:
Allows you to enter the message that will be sent to the downloaded data about the configured alarm. The message body
will be identical for all emails.