Intended Purpose
The
CyBio
®
Well
vario
provides
a
simultaneous
multi-pipetting
tool
for
automated
pro-
cessing
of
microplates
with
96,
384
or
1536
wells
according
to
the
SBS
standard.
Its
ba-
sic
functions
are:
dosing,
pipetting,
dispensing,
diluting,
rinsing,
tip
change
and
pipetting
head
replacement,
as
well
as
transportation
of
microplates.
In
addition,
it
al-
lows
non-contact
pipetting
to
be
performed
when
the
capillary
head
is
installed.
Op-
tional
extra
functions
are,
for example,
the
stockpiling
of
microplates
(when
working
with
stackers)
and
a
reservoir
filling
station.
Depending
on
the
product
design
version,
a
head
may
be
replaced
from
the
front
or
from
the
back.
The
CyBio
®
Well
vario
pipettor
is
intended
for
laboratories
doing
research
and
develop-
ment
in
the
fields
of
pharmacy,
biochemistry,
clinical
chemistry,
combinatorial
chemistry,
molecular
biology,
molecular
genetics
and
cell
biology,
as
well
as
any
laboratory
where
pipetting
operations
have
to
be
carried
out
in
a
highly
parallel,
rapid
and
precise
man-
ner.
Users
are
required
to
operate
this
system
in
no
way
or
mode
other
than
described
or
specified
in
this
User
Manual.
The
system's
range
of
applications
is
limited
by
the
func-
tional
scope
of
available
software
and
firmware
and
by
the
scope
of
delivery.
1.3
Conforming Use
The
term
conforming use
of
the
CyBio
®
Well
vario
presumes
that:
the
system
is
operated
by
qualified
and
trained
research
and
laboratory
personnel
all
operating
requirements
quoted
in
this
User
Manual
and
described
procedural
sequences
and
related
safety
notes
are
duly
observed
all
specifications
in
this
Manual
regarding
system
start-up,
operation,
preventive
maintenance
and
care
are
met
applicable
safety
standards
or
rules
are
always
fulfilled.
Any
type
of
mode
of
application
other
than
specified
herein
will
be
regarded
as
non-
conforming
use!
The
user
will
be
solely
liable
for
any
damage
resulting
from
a
non-con-
formance.
The
term
non-conforming use
will
include,
but
is
not
limited
to:
operating
the
system
in
medical
laboratories
working
with
explosive
substances
working
in
potentially
explosive
atmospheres
NOTE
Analytik
Jena
AG
will
refuse
any
claims
for
warranty
and
liability
for
material
damage
and
personal
injury
if
the
CyBio
®
Well
vario
is
shown
to
have
been
subject
to
non-con-
forming use
!
Содержание CyBio Well vario OL3381-25-300
Страница 1: ...Operating Manual CyBio Well vario...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 16: ...XVI Release 2017 CyBio Well vario...
Страница 26: ...10 Release 2017 CyBio Well vario Technical Specifications...
Страница 60: ...44 Release 2017 CyBio Well vario Technical Description...
Страница 74: ...58 Release 2017 CyBio Well vario Initial Start Up Routine Start Up Procedure...
Страница 138: ...122 Release 2017 CyBio Well vario Maintenance Care...
Страница 144: ...128 Release 2017 CyBio Well vario Accessories Spare Parts...
Страница 146: ...130 Release 2017 CyBio Well vario Waste Disposal...
Страница 148: ...132 Release 2017 CyBio Well vario...
Страница 158: ...142 Release 2017 CyBio Well vario...
Страница 160: ...144 Release 2017 CyBio Well vario...
Страница 164: ...148 Release 2017 CyBio Well vario...