INSTALLATION & 

OPERATION MANUAL

VTC615 SERIES
Voltage Converter

8128 River Way, Delta B.C. V4G 1K5  Canada  T. 604.946.9981  F. 604.946.9983  TF. 800.668.3884  (US/CANADA)

www.analyticsystems.com

An ISO9001 and AS9100 Registered Company 

Battery Chargers 

 Inverters 

 Power Supplies 

 Voltage Converters

Содержание VTC615 Series

Страница 1: ...S Voltage Converter 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers In...

Страница 2: ...Copyright 2005 2014 Analytic Systems Ware 1993 Ltd...

Страница 3: ...ttery acid to drip on converter when reading gravity or filling battery 7 DC CONNECTION PRECAUTIONS i Connect and disconnect DC output connections only after setting converter switch to off position A...

Страница 4: ...to the converter The VTC615 Series Voltage Converter supplies either 12 24 32 or 48 VDC from a 24 36 48 or 72 VDC power source Other input or output voltages up to 72 volts are also available by spec...

Страница 5: ...Dimensions 14 5 x 10 x 4 in 37 x 25 x 10 cm Clearance 1 Inch 2 5 cm all around Material Marine Grade Aluminum Finish Black Powder Epoxy Fastenings 18 8 Stainless Weight 7 2 lb 3 3 kg Actual startup is...

Страница 6: ...o Negative output terminals are provided Connect only one wire to each terminal Ensure that the total average load connected does not exceed the continuous current rating of the unit LOAD SHARE OPTION...

Страница 7: ...ncreases the output voltage and counter clockwise decreases it When you are done replace the cover plate and securely tighten the screws METERS A high quality digital meter can be added to the voltage...

Страница 8: ...tage to drop to maintain the current at the maximum level The input voltage is not high enough for unit to operate LOW INPUT Indicates that the input voltage is below normal because The input voltage...

Страница 9: ...erated remotely as well as duplicating all the diagnostic indicators and audible alarm This connector is located on the side of the unit Important To prevent the possibility of High Voltage Electrical...

Страница 10: ...p Components Conformal Dipping and RTV Compound Option w Wide Temperature Operation 40 to 55 C incl Option SM High Voltage Protection on the DC Input Side Option d Paralleling Diodes Option FI Forklif...

Страница 11: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Страница 12: ...Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage...

Отзывы: