The Model FBCS-2K Series Power Supply has been designed to charge forklifts and it is based on two (2) 

PWS 1000d power supply connected in parallel and placed in a metal enclosure. It supplies 27.2 VDC from 

a 110 Vac electrical system. A state of the Art Switchmode design offers high reliability, high efficiency and 

minimum size. 

All new Current Mode switching design offers increased power and reliability in a compact package.  Extra 

input and output filtering reduce EMI to extremely low levels.  Reliability features include an input fuse, 

thermal shutdown, current limiting and output short circuit shutdown with automatic recovery.  The output 

voltage is easily adjusted 1.0 volts above or below the standard output voltage.  The model PWS1000 Power 

Supply supplies either 12, 24 or 48 VDC from a 110 or 220 VAC power source.  High quality digital meters 

can be added (factory option) to allow monitoring of charging current and charging voltage.  Other output 

voltages up to 72 volts are also available by special order.

Below electrical specifications are per one unit model PWS1000d.

Specifications

Input Voltages
Nominal (ip)

110Vac

220Vac

Actual

90 - 130Vac

180 - 260Vac

Input Amps (max)

13.2(12V) / 17(24/32/48V)

6.6(12V) / 8.5(24/32/48V)

Input Fuse (slow blow)

MDA-20(12V) / MDA-25 (24/32/48V) MDA-10(12V) / MDA-15(24/32/48V)

Output Voltages
Nominal (op)

12Vdc

24Vdc

32Vdc

48Vdc

Actual

13.6 ± 0.05Vdc

27.2 ± 0.05Vdc

36.3 ± 0.05Vdc

54.4 ± 0.10Vdc

Adjust

± 1.0 Vdc

Output Crowbar

16.0 ± 0.5 Vdc

32.0 ± 1.0 Vdc

42.7 ± 1.3 Vdc

63.9 ± 2.0 Vdc

Output Amps (cont)

60

40

30

20

Output Amps (max)

70

45

34

22.5

Содержание FBCS-2K-110-36

Страница 1: ...Installation Operation Manual FBCS 2K Power Supply 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 1 800 668 3884 US CANADA www analyticsystems com...

Страница 2: ...2 Copyright 2005 2013 Analytic Systems Ware 1993 Ltd...

Страница 3: ...D AC POWER CORD CONNECTION INSTRUCTIONS The plug must be plugged into an outlet that is properly installed and grounded in accordance with al local codes and ordinances DANGER Never alter AC cord or p...

Страница 4: ...ed 1 0 volts above or below the standard output voltage The model PWS1000 Power Supply supplies either 12 24 or 48 VDC from a 110 or 220 VAC power source High quality digital meters can be added facto...

Страница 5: ...put Frequency 45 65 Hz Noise on Input 50 milli Volts Noise on Output 50 milli Volts Transient Response 1 V for 50 surge Efficiency 80 maximum output Temp Range 25 to 40 deg C maximum output Isolation...

Страница 6: ...nd Green Yellow Ground All connections should be made inside an appropriate junction box The maximum current draw from the 110 VAC supply is 14 6 amps so a 20 amp circuit breaker should be used in the...

Страница 7: ...equiped with the optional output isolation diodes To confirm that your unit has these diodes use an ohmmeter to measure the resistance between the two positive output terminals If the diodes are pres...

Страница 8: ...at the output voltage is below normal because The current demanded by the devices connected to the unit exceeds the maximum output current rating thereby causing the output voltage to drop to maintain...

Страница 9: ...the cover and locate J10 It will be next to the relay K1 as is shown in the above diagram Simply move the jumper to the desired position as is shown in the above diagram Replace the cover and re insta...

Страница 10: ...the Purchas ers name address and telephone number b Call Analytic Systems at 800 668 3884 or 604 946 9981 and request a return material authorization number RMA c Return the defective part or unit alo...

Страница 11: ...tability fitness for the ordinary purposes for which such goods are used or fitness for a particular purpose or any other obligations on the part of the Warrantor or its employees and representatives...

Отзывы: