Analytic Systems BCD615 SERIES Скачать руководство пользователя страница 1

INSTALLATION & 

OPERATION MANUAL

BCD615 SERIES
DC Battery Charger

8128 River Way, Delta B.C. V4G 1K5  Canada  T. 604.946.9981  F. 604.946.9983  TF. 800.668.3884  (US/CANADA)

www.analyticsystems.com

An ISO9001 and AS9100 Registered Company 

Battery Chargers 

 Inverters 

 Power Supplies 

 Voltage Converters

Содержание BCD615 SERIES

Страница 1: ...S DC Battery Charger 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers I...

Страница 2: ...Copyright 2005 2014 Analytic Systems Ware 1993 Ltd...

Страница 3: ...er switch to the off position ALL BATTERY CHARGERS 1 1 WARNING RISK OF EXPLOSIVE GASES i WORKING IN VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTER...

Страница 4: ...and recommended rates of charge xiii Add distilled water in each cell until battery acid reaches level specified by battery manufacturer This helps purge excessive gas from cells Do not overfill For...

Страница 5: ...h quality digital meters can be added factory option to allow monitoring of output current and output voltage Specifications Input Voltages Nominal ip 24 48 72 Actual 20 35 40 60 65 90 Input Amps max...

Страница 6: ...re Red Positive Black Negative Designed and manufactured by ANALYTIC SYSTEMS WARE 1993 LTD 8128 River Way Delta BC V4G 1K5 Canada p 604 946 9981 f 604 946 9983 tf 800 668 3884 US Canada www analyticsy...

Страница 7: ...or float voltage 2 stage and the charging current will reduce as necessary to maintain the batteries at that voltage Once the charging current has dropped to a low level about 15 of the charging curr...

Страница 8: ...hten the screws It is advisable to check with the battery manufacturer before changing the float voltage Meters A high quality digital meter can be added to the voltage converter factory installed onl...

Страница 9: ...Bulk Constant Current Float Constant Volts Time Two Stage Charge Volts Amps 100 75 50 25 0 Bulk Constant Current Absorption Constant Volts Float Constant Volts Time Three Stage Charge Volts Amps 2 or...

Страница 10: ...xceeds the maximum output current rating causing the output voltage to drop to maintain the current at the maximum level The input voltage is not high enough for unit to operate LOW INPUT Indicates th...

Страница 11: ...rge the capacitors then turn it off again Remove the eight screws holding on the cover Turn the unit upside down remove the cover and locate J10 It will be next to the relay K1 as is shown in the abov...

Страница 12: ...of sulfation of the battery During the Equalize cycle the cells which are fully charged will produce Hydrogen gas and the cells which are undercharged will be brought up to full charge An Equalize cyc...

Страница 13: ...used during an equalize cycle or damage to the battery may occur The battery temperature sensor may be installed in many different ways so long as the sensor stays in contact with the battery The pref...

Страница 14: ...p Components Conformal Dipping and RTV Compound Option w Wide Temperature Operation 40 to 55 C incl Option SM High Voltage Protection on the DC Input Side Option d Paralleling Diodes Option FI Forklif...

Страница 15: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Страница 16: ...Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage...

Отзывы: