background image

ANALOG WAY

PAGE 2

SMS100 - ED 07/01

SAFETY INSTRUCTIONS : ENGLISH

INSTRUCTIONS : All of the safety and operating instructions should be read before the product is operated and should be retained for further reference.
Please follow all of the warnings on this product and its operating instructions.

CAUTION :
WARNING : To prevent the risk of electric shock and fire, do not expose this device to rain, humidity or intense heat sources (such as radiators or direct
sunlight).
SLOTS AND OPENINGS in the device are provided for ventilation and to avoid overheating. Make sure the device is never placed on or
near a textile surface that could block the openings. Also keep away from excessive dust, vibrations and shocks.

POWER : Only use the power supply indicated on the device or on the power source.
Devices equipped with a grounding plug should only be used with a grounding type outlet. In no way should this grounding bemodified, avoided or
suppressed.
POWER CORD : Use the On (I) / Off (O) switch to power On or Off devices equipped with that switch. All other devices should be plugged and
unplugged from wall outlet.
In both cases, please follow these instructions :
- The power cord of the device should be unplugged from the outlet when left unused for several days.
- To unplug the device, do not pull on the power cord but always on the plug itself.
- The outlet should always be near the device and easily accessible.
- Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them.
If the power supply cord is damaged, unplug the device. Using the device with a damaged power supply cord may expose you to electric shocks or other
hazards.
Verify the condition of the power supply cords once in a while. Contact your dealer or service center for replacement if damaged.

CONNECTIONS : All inputs and outputs (except for the power input) are TBTS defined under EN60950.

SERVICING : Do not attempt to service this product yourself by opening or removing covers and screws since it may expose you to electric shocks or
other hazards. Refer all problems to qualified service personnel.

OPENINGS : Never push objects of any kind into this product through the openings. If liquids have been spilled or objects have follen into the
product, have a qualified technician check it before re-using it.

INSTRUCTIONS DE SECURITE : FRANÇAIS

INSTRUCTION : Afin de mieux comprendre le fonctionnement de cet appareil nous vous conseillons de bien lire toutes les consignes de sécurité et de
fonctionnement de l’appareil avant utilisation. Conserver les instructions de sécurité et de fonctionnement afin de pouvoir les consulter ultérieurement.
Respecter toutes les consignes marquées dans la documentation, sur le produit et sur ce document.

PRÉCAUTION & AVERTISSEMENT :
ATTENTION : Afin de prévenir tout risque de choc électrique et d’incendie, ne pas exposer cet appareil à la pluie, à l’humidité et aux
sources de chaleur intenses.

INSTALLATION : Veillez à assurer une circulation d’air suffisante pour éviter toute surchauffe à l’intérieur de l’appareil.
Ne placez pas l’appareil sur et à proximité de surface textile susceptible d’obstruer les orifices de ventilation.
N’installez pas l’appareil à proximité de sources de chaleur comme un radiateur ou une bouche d’air chaud, ni dans un endroit exposé au rayonnement
solaire direct, à des poussières excessives, à des vibrations ou à des chocs mécaniques. Ceci pourrait provoquer un mauvais fonctionnement et un accident.

ALIMENTATION : Ne faire fonctionner l’appareil qu’avec la source d’alimentation indiquée sur l’appareil ou sur son bloc alimentation.
Pour  les appareils équipés d’une alimentation principale avec fil de terre, ils doivent être obligatoirement connectés sur une source équipée d’une mise à
la terre efficace. En aucun cas cette liaison de terre ne devra être modifiée, contournée ou supprimée.

CORDON D’ALIMENTATION : Pour les appareils équipés d’un interrupteur général (Marche I / Arrêt O), la mise sous tension et la mise hors tension se
fait en actionnant cet interrupteur général.
Pour les appareils sans interrupteur général, la mise sous tension et la mise hors tension se fait directement en connectant et déconnectant
la prise murale.
Dans les 2 cas ci-dessus appliquer les consignes suivantes : 
- Débrancher l’appareil de la prise murale si vous prévoyez de ne pas l’utiliser pendant quelques jours ou plus.
- Pour débrancher le cordon, tirez le par la fiche. Ne tirez jamais sur le cordon proprement dit.
- La prise d’alimentation doit se trouver à proximité de l’appareil et être aisément accessible.
- Ne laissez pas tomber le cordon d’alimentation et ne posez pas d’objets lourds dessus.

Si le cordon d’alimentation est endommagé, mettez immédiatement l’appareil hors tension. Il est dangereux de faire fonctionner cet appareil avec un
cordon endommagé, un câble abîmé peut provoquer un risque d’incendie ou un choc électrique. Vérifier le câble
d’alimentation de temps en temps. Contacter votre revendeur ou le service après vente pour un remplacement.

CONNECTIONS : Toutes les entrées et sorties (exceptée l’entrée secteur) sont de type TBTS (Très Basse Tension de Sécurité) définies
selon EN 60950.

RÉPARATION ET MAINTENANCE : L’utilisateur ne doit en aucun cas essayer de procéder aux opérations de dépannage, car l’ouverture des appareils
par retrait des capots ou de toutes autres pièces constituant les boîtiers ainsi que le dévissage des vis apparentes à l’extérieur, risque d’exposer l’utilisateur
à des chocs électriques ou autres dangers.
Contacter le service après vente ou votre revendeur ou s’adresser à un personnel qualifié uniquement.

OUVERTURES ET ORIFICES : Les appareils peuvent comporter des ouvertures (aération, fentes, etc...), veuillez ne jamais y introduire d’objets et ne
jamais obstruer ses ouvertures. Si un liquide ou un objet pénètre à l’intérieur de l’appareil, débranchez l’appareil et faites le contrôler par un personnel
qualifié avant de le remettre en service.

Содержание SMS100 Smart Scaler

Страница 1: ...ctions PAGE 4 Supplied Equipment and General Information PAGE 5 Installing PAGES 6 Technical Description PAGES 7 9 Starting PAGES 10 15 LCD Menu Control PAGE 16 Operating Mode PAGES 17 18 Technical Sp...

Страница 2: ...e ne pas exposer cet appareil la pluie l humidit et aux sources de chaleur intenses INSTALLATION Veillez assurer une circulation d air suffisante pour viter toute surchauffe l int rieur de l appareil...

Страница 3: ...le recomendamos que lea cuidadosamente todas las consignas de seguridad y de funcionamiento del aparato antes de usarlo Conserve las instrucciones de seguridad y de funcionamiento para que pueda consu...

Страница 4: ...y decoder includes an Advanced Comb Filter an anphasized natural color processing a highly robust sync detection and a new enhanced 3D auto adaptive de interlacing scheme for motion artifacts with cor...

Страница 5: ...a 19 rack Screw the supplied 19 brackets to the sides of the SMART SCALER Put the SMART SCALER into the rack NOTE the 19 front panel screws are not included The openings in the top cover and in the r...

Страница 6: ...60Hz REMOTE RS 232 Standard remote control on DB9 Female connector COMPUTER INPUT Computer PC MAC WORKSTATION input on HD15 Female connector ROOM 12Vdc TRIGGER A Room command output 3 5 mm JACK female...

Страница 7: ...of your display device data projector plasma screen on the DISPLAY OUTPUT of the SMART SCALER h Turn ON all of your input sources the SMART SCALER front panel switch and then your display device i Sel...

Страница 8: ...The S VIDEO connector is usually a 4 pin Mini DIN connector also called Oshiden connector CONNECTION RGB S INPUT The RGB S signal also called RGB Sync is a RGB signal with COMPOSITE sync This signal...

Страница 9: ...sent directly to the display output Also you may connect a Computer source PC MAC WORKSTATION or a high definition source progressive DVD player HDTV Use the VGA supplied cable HD15 male male to conne...

Страница 10: ...f the front panel buttons 6 2 LCD MENUS LCD DIAGRAM 2 output format INPUT STATUS LCD CONTROL MENUS output sync H V COMP video standard auto manual SMART SCALER SMS100 OUTPUT STATUS LCD STATUS MENUS Ad...

Страница 11: ...DARD OF THE DISPLAYED INPUT LCD CONTROL MENUS 1 INPUT MENU ENTER 1 1 VIDEO STANDARD ENTER Select an item with ENTER AUTO Automatic recognition of the video standard for all inputs PAL NTSC SECAM Black...

Страница 12: ...Input line frequency Input frame frequency kHz Hz 2 OUTPUT MENU ENTER 2 1 OUTPUT SYNC ENTER Select the Output Sync type with ENTER H V H V Separate Sync COMP Composite Sync 2 2 OUTPUT FORMAT ENTER If...

Страница 13: ...th ENTER INTERNAL RATE The output Frame Rate is 60 Hz or 75 Hz depending of the selected OUTPUT format LCD menu 2 2 A high level frame frequency gives a better visual aspect when displaying static pic...

Страница 14: ...ENTER Adjust the Brightness with ENTER 3 8 CONTRAST ENTER Adjust the Contrast with ENTER 3 9 COLOR ENTER Adjust the Color with ENTER 3 10 HUE ENTER Adjust the Tint of the picture NTSC only with ENTER...

Страница 15: ...black when switching between sources SHORT 1 second delay LONG 3 seconds delay 4 4 VERSION ENTER Status of the internal firmware K xxxx L xxxx R xxxx V xxxx 4 5 DEFAULT VALUE ENTER NO No Adjustments...

Страница 16: ...Frame Rate of the selected video input 50 Hz if PAL or SECAM and 59 94 Hz if NTSC Generated by the SMART SCALER 60 Hz or 75 Hz 640 x 480 4 3 VGA at 50 or 59 94 Hz VGA 640 x 480 at 60 Hz or 75 Hz 852 x...

Страница 17: ...BNC CONNECTOR PAL SECAM 15 625 kHz 50 Hz 625L NTSC 3 58MHz 4 43 MHz 15 735 kHz 60 Hz 525L Level 1 Vp p 0 7 Vp p Luma 0 3 Vp p Sync Impedance 75 Ohms 8 2 COMPUTER INPUT 15 PINS HD F CONNECTORS Hardwar...

Страница 18: ...wer Switch ON command 12 Vdc If AC Power Switch OFF command 0 Vdc Output Current 0 1 A max at 12 Vdc Connection 3 5 JACK MALE CONNECTOR STEREO or MONO Command Ground 8 6 ENVIRONMENTAL Power Supply Int...

Страница 19: ...ontrolling Device computer to the REMOTE CONTROL RS 232 connector DB 9 F of the SMART SCALER with a straight cable DB 9 Female DB 9 Male PIN OUT Pin Functions 2 TRANSMIT DATA Tx 3 RECEIVE DATA Rx 5 GR...

Страница 20: ...LER receives a valid command it will execute the command and send a response back to the host device If the command is invalid an error response will be returned to the host All responses to the host...

Страница 21: ...0 255 157S VSIZ157 SETS V SIZE TO 157 B BRGT BRIGHTNESS ADJUSTMENT 0 255 B BRGT15 READS BRIGHTNESS LEVEL C CONTR CONTRAST ADJUSTMENT 0 255 C CONTR50 READS CONTRAST LEVEL s COLOR COLOR SATURATION 0 255...

Страница 22: ...ction EXAMPLE Host receives message CSTA3 P command Decimal value 3 Binary value 011 3 4 x 0 2 x 1 1 x 1 bit 0 1 means Sync detected bit 1 1 means Comp Sync detected bit 2 0 means non interlaced forma...

Страница 23: ...z or 59 94 Hz OFMT6 14 HDTV 720 P 1280 x 720 at 50Hz or 59 94 Hz OFMT14 15 QUAD 960 1280 x 960 at 50Hz or 59 94 Hz OFMT15 16 D ILA 1365 x 1024 at 50Hz or 59 94 Hz OFMT16 Use the following table when t...

Страница 24: ...IASP1 2 Widescreen Anamorphic IASP2 j A Q N commands are used to control the output adjustments 0 minimum 63 maximum f STATUS COMMANDS READ ONLY This control family is read only it cannot be preceded...

Страница 25: ...10 2 NTSC 3 58 60 Hz VSTA2 11 B W 50 Hz VSTA11 3 NTSC 3 58 50 Hz VSTA3 12 B W 60 Hz VSTA12 4 NTSC 4 43 60 Hz VSTA4 13 YUV 50 Hz VSTA13 5 NTSC 4 43 50 Hz VSTA5 14 YUV 60 Hz VSTA14 6 PAL 3 58 60 Hz VSTA...

Страница 26: ...8 Bit 2 4 Bit 1 2 Bit 0 1 Reserved Reserved 0 Adaptive Black OFF 1 Adaptive Black ON 1 Default value action 1 Image Preset action Please see LCD Menu 3 12 00 Unlock action 01 All lock action 1 Freeze...

Страница 27: ...4 29 41 I 49 73 i 69 105 2A 42 J 4A 74 j 6A 106 2B 43 K 4B 75 k 6B 107 2C 44 L 4C 76 l 6C 108 2D 45 M 4D 77 m 6D 109 2E 46 N 4E 78 n 6E 110 2 F 47 O 4 F 79 o 6 F 111 0 30 48 P 50 80 p 70 112 1 31 49 Q...

Страница 28: ...evice is compatible with the selected output sync type Chapter 6 LCD menu 2 1 Display device user s manual NO PICTURE The LCD input status displays the right status of the video For example S Video 1...

Страница 29: ...including free material and labor This warranty does not apply if the product has been improperly installed or abused handled with improper care used or stocked in abnormal conditions modified opened...

Отзывы: