Programmer ’s Guide
Axion2
Страница 1: ...Programmer s Guide Axion2...
Страница 2: ...t will be executed Then it will send back the status of the parameters that have changed due to this command If the command cannot be executed value out of range device not ready etc the Axion2 will j...
Страница 3: ...ue DEV Device Type Read 96 96 96 Axion2 Request all current commands values ReadWrite 0 1 1 Request 0 when completed rA rA Axion2 Ready Status Read 0 1 1 Ready rS rS Screen Ready Status Read 0 1 0 Scr...
Страница 4: ...re the Preview ReadWrite 0 90 0 None 1 Load Memory 1 90 Load Memory 90 PL PL Load a Preset Memory using current screen filter and configure the Preview ReadWrite 0 90 0 None 1 Load Memory 1 90 Load Me...
Страница 5: ...ion Access Min MAX Index 1 Index 2 Index 3 Value SF SF Screen Filter Disable Enable Preset Load and Take per Screen ReadWrite 0 1 0 Screen1 5 Screen6 1 Enabled TK TK Take as soon as devices are ready...
Страница 6: ...10 PL PL10 CR LF Load the Preset Memory 10 2 2 4 6 SS SS2 2 4 6 CR LF Put the source 6 into the 5th PIP of screen 3 Read command Answer Description Index Characters DEV96 CR LF Get the Device Type 96...