background image

 

 

16 A

NALOG 

D

EVICES

,

 

I

NC

.

 

C

ONFIDENTIAL

 DC9006A

 AND 

DC9004B

 

U

SER 

G

UIDE

 

Pin #  Signal (J1) 

Dir. 

 

Pin #  Signal (J2) 

Dir.

13 NC 

-   

13 FLASH_P_ENn 

Signal direction is relative to the Programming Adapter board 

Limitations  

Ribbon Cable Length 

Evaluation kits are shipped with the latest version for the DC9006.  However, for 
early versions of the DC9006 (700-0184 rev5 or earlier), the maximum 

recommended ribbon cable length is 2 inches. 

Voltage Level 

In the configuration where the customer board is independently powered, JP7 on 
the DC9006 Interface card must be set to the “OFF” position and the voltage supply 

must be greater than 2.7V.  

Current Limit 

In the configuration where the customer board requires high current, jumper P4 on 

the DC9006 Interface card shall be installed in order to short the sense resistor R55 
(see 

 

Figure 3,  Current Sensing Jumpers, for details).  

Feature Comparison with DC9010 

The following table shows a feature comparison between the DC9006 and the 

DC9010 Eterna Programmer (See 

Eterna Serial Programmer Guide

). 

 

Eterna FLASH SPI Programming 

JTAG Adapter 

DUT 

Power 

Auto-

Detection 

Crystal 

Calibration 

LTP5900 

 

Header 

(2x5 

2mm) 

Header 

(2x5 

.050”) 

TAG-

Connect 

(TC2050-

IDC) 

Header 

(2x5 

2mm) 

TAG-

Connect 

(TC2030-

CTX-20) 

 

4 Hz PPS 

with TCXO 

22/26-pin 

2mm 

socket 

DC9006 

w/DC9004A 

9

 

 

 

 

 

 

 

 

DC9006 

w/DC9004B 

9

 

9

 

9

 

9

 

9

 

 

 

9

(*)

DC9010A 

9

 

9

(**)

 

 

 

 

9

 

9

 

9

  

(*) (**)

(*) LTP5900 does not include CLI; (**) Requires opening the DC9010A enclosure. 

Содержание Dust Networks DC9004B

Страница 1: ...Dust Networks Eterna Evaluation Development DC9006A and DC9004B User Guide Interface Card Programming JTAG Adapter...

Страница 2: ...mper Settings 9 Interface Signal Disconnection 10 External JTAG Reset Pushbutton 10 Eterna Evaluation and Development Mote Socket Pinout 11 Programming Adapter DC9004B 12 Introduction 12 Usage 13 Inte...

Страница 3: ...ote Datasheet LTC5800 IPR SmartMesh IP Manager Datasheet LTC5800 WHM SmartMesh WirelessHART Mote Datasheet Eterna Board Specific Parameter Configuration Guide Eterna Serial Programmer Guide Eterna 580...

Страница 4: ...story Revision Date Description 1 May 19 2017 First Release 2 July 11 2017 Added footer ADI Confidential notice Internal Document Number 040 0132 4 ANALOG DEVICES INC CONFIDENTIAL DC9006A AND DC9004B...

Страница 5: ...tures test points to monitor the mote current consumption and jumpers for various configurations Figure 1 DC9018B Mote left connected to the DC9006A Interface Card right Installation The Interface Car...

Страница 6: ...al Programmer Guide Setup For details on operating the Eterna Evaluation Development Board Set in a network please refer to the starter kit documentation SmartMesh IP Easy Start Guide or SmartMesh Wir...

Страница 7: ...ard JTAG JTAG is only supported with an external JTAG device not included such as I Jet from IAR with a 20pin 1 adapter or J Link from Segger The external JTAG device must be connected to the JTAG Hea...

Страница 8: ...ures signals that are directly connected to the Eterna Evaluation Development Board connector P1 signals are referenced to the isolated ground Power Switch Over The Interface Card compares its VCCA ra...

Страница 9: ...be installed see section Mote Signal Disconnection Note In applications where a high current is required jumper P4 shall be installed this shunts the sense resistor R55 and eliminates the associated...

Страница 10: ...rmally be installed in the ON position pin 1 2 the OFF position pin 2 3 may be used to disconnect the Interface Card from the USB 5V supply ON 1 JP10 Connects the Eterna Evaluation and Development Boa...

Страница 11: ...Eterna Evaluation and Development Board Pin Signal Direction Pin Signal Direction 1 UART_TX_CTSn O 2 UART_TX_RTSn I 3 UART_TX I 4 GND 5 UART_RX O 6 UART_RX_RTSn O 7 UART_RX_CTSn I 8 UARTC0_TX UARTC1_T...

Страница 12: ...llowing customer board connections the 2x5 2mm pitch programming header described in the integration guide a 050 pitch variant of the programming header a 2x5 surface mount programming footprint match...

Страница 13: ...pitch 2x16 header with the same signals described in section Eterna Evaluation and Development Mote Socket Pinout Programming Interface Headers 2x5 0 050 2mm and 100 pitch The programming headers are...

Страница 14: ...ut of the JTAG P6 MOLEX 878321020 Pin Signal Direction Pin Signal Direction 1 TCK O 2 GND O 3 TMS O 4 TDO I 5 GND 6 TDI O 7 GND 8 RESETn 9 VSUPPLY 10 NC Signal direction is relative to the Programming...

Страница 15: ...connect the following signals to the customer board footprint below VSUPPLY GND RESETn TMS TDO TCK Figure 9 Tag Connect SWD Footprint LTP5900 Socket 26 pin 2mm pitch The following table describes the...

Страница 16: ...ust be greater than 2 7V Current Limit In the configuration where the customer board requires high current jumper P4 on the DC9006 Interface card shall be installed in order to short the sense resisto...

Страница 17: ...ILITY OR FITNESS FOR ANY PARTICULAR PURPOSE EXCEPT TO THE EXTENT OF THIS INDEMNITY NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES The user assu...

Страница 18: ...indirectly any claim of personal injury or death associated with such unintended or unauthorized use even if such claim alleges that Dust Networks was negligent regarding the design or manufacture of...

Страница 19: ...DC9006A AND DC9004B USER GUIDE ANALOG DEVICES INC CONFIDENTIAL 19 Page Intentionally Left Blank...