ADT7476
Rev. B | Page 43 of 72
05382-053
REAR CHASSIS
FRONT CHASSIS
CPU FAN SINK
LOCAL =
VRM TEMP
PWM1
PWM2
TACH1
TACH2
TACH3
PWM3
REMOTE 1 =
AMBIENT TEMP
REMOTE 2 =
CPU TEMP
THERMAL CALIBRATION
0%
T
MIN
T
RANGE
THERMAL CALIBRATION
100%
0%
T
MIN
T
RANGE
THERMAL CALIBRATION
100%
0%
T
MIN
T
RANGE
PWM
MIN
PWM
MIN
PWM
MIN
100%
MUX
PWM
GENERATOR
PWM
GENERATOR
TACHOMETER 3
AND 4
MEASUREMENT
TACHOMETER 1
MEASUREMENT
TACHOMETER 2
MEASUREMENT
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM
GENERATOR
PWM
CONFIG
PWM
CONFIG
PWM
CONFIG
Figure 52. MUX Configuration Example
STEP 3: T
MIN
SETTINGS FOR THERMAL
CALIBRATION CHANNELS
T
MIN
is the temperature at which the fans start to turn on under
automatic fan control. The speed at which the fan runs at T
MIN
is programmed later. The T
MIN
values chosen are temperature
channel specific, for example, 25°C for ambient channel, 30°C
for VRM temperature, and 40°C for processor temperature.
T
MIN
is an 8-bit value, either twos complement or Offset 64, that
can be programmed in 1°C increments. A T
MIN
register is assoc-
iated with each temperature measurement channel: Remote 1
local and Remote 2 temperature. Once the T
MIN
value is exceeded,
the fan turns on and runs at the minimum PWM duty cycle.
The fan turns off once the temperature has dropped below T
MIN
− T
HYST
.
To overcome fan inertia, the fan is spun up until two valid TACH
rising edges are counted. (See the Fan Start-up Timeout section
for more details.) In some cases, primarily for psycho-acoustic
reasons, it is desirable that the fan never switch off below T
MIN
.
When set, Bits [7:5] of Enhanced Acoustics Register 1 (0x62)
keep the fans running at the PWM minimum duty cycle if the
temperature should fall below T
MIN
.
T
MIN
Registers
Register 0x67, Remote 1 Temperature T
MIN
= 0x5A (90°C)
Register 0x68, Local Temperature T
MIN
= 0x5A (90°C)
Register 0x69, Remote 2 Temperature T
MIN
= 0x5A (90°C)
Enhanced Acoustics Register 1 (0x62)
Bit 7 (MIN3) = 0,
PWM3 is off (0% PWM duty cycle) when
temperature is below T
MIN
− T
HYST
.
Bit 7 (MIN3) = 1,
PWM3 runs at PWM3 minimum duty cycle
below T
MIN
− T
HYST
.
Bit 6 (MIN2) = 0,
PWM2 is off (0% PWM duty cycle) when
temperature is below T
MIN
− T
HYST
.
Bit 6 (MIN2) = 1,
PWM2 runs at PWM2 minimum duty cycle
below T
MIN
− T
HYST
.
Bit 5 (MIN1) = 0, PWM1 is off (0% PWM duty cycle) when
temperature is below T
MIN
− T
HYST
.
Bit 5 (MIN1) = 1,
PWM1 runs at PWM1 minimum duty cycle
below T
MIN
− T
HYST
.