SPI DMA Enable Register
Address: 0x4002C014, Reset: 0x0000, Name: SPI0DMA
Table 184. Bit Descriptions for SPI0DMA
Bits
Bit Name
Description
Reset
Access
[15:3]
RESERVED
Reserved.
0x0
R
2
IENRXDMA
Enable receive DMA request.
0x0
RW
0: disable RX DMA interrupt
1: enable RX DMA interrupt
1
IENTXDMA
Enable transmit DMA request.
0x0
RW
0: disable TX DMA interrupt
1: enable TX DMA interrupt
0
ENABLE
Enable DMA for data transfer. Set by user code to start a DMA transfer.
Cleared by user code at the end of DMA transfer. This bit needs to be
cleared to prevent extra DMA request to the µDMA controller.
0x0
RW
Transfer Byte Count Register
Address: 0x4002C018, Reset: 0x0000, Name: SPI0CNT
Table 185. Bit Descriptions for SPI0CNT
Bits
Bit Name
Description
Reset
Access
[15:8]
RESERVED
Reserved.
0x0
R
[7:0]
COUNT
Transfer byte count. COUNT indicates the number of bytes to be
transferred. Count is used in both receive and transmit transfer types. The
COUNT value assures that a master mode transfer terminates at the proper
time and that 16-bit DMA transfers are byte padded or discarded as
required to match odd transfer counts. Reset by clearing SPI0CON[0] or if
SPI0CNT is updated.
0x0
RW
REGISTER SUMMARY: SPI1
Table 186. SPI1 Register Summary
Address
Name
Description
Reset
RW
0x40030000
SPI1STA
Status register
0x0000
R
0x40030004
SPI1RX
Receive register
0x0000
R
0x40030008
SPI1TX
Transmit register
0x0000
W
0x4003000C
SPI1DIV
Baud rate selection register
0x0000
RW
0x40030010
SPI1CON
SPI configuration register
0x0000
RW
0x40030014
SPI1DMA
SPI DMA enable register
0x0000
RW
0x40030018
SPI1CNT
Transfer byte count register
0x0000
RW
REGISTER DETAILS: SPI1
Status Register
Address: 0x40030000, Reset: 0x0000, Name: SPI1STA
Table 187. Bit Descriptions for SPI1STA
Bits
Bit Name
Description
Reset
Access
15
RESERVED
Reserved.
0x0
R
14
CSRSG
Detected a rising edge on CS, in CONT mode. This bit causes an interrupt.
This can be used to identify the end of an SPI data frame.
0x0
RC
0: cleared to 0 when the status register is read
1: set to 1 when there was a rising edge in CS line, when the device was in
master mode, continuous transfer, high frequency mode and CSIRQ_EN
was asserted.